Planning Guides
Page 1
... and DR30EFS are compatible with a raised vent. Use only theses specified raised vent models. www.dacor.com Phone: (800) 793-0093 DR30ES, DR30EFS, DR30EIS, DR30EIFS Document # PG05-008 Distinctive™ 30" Wide Electric Ranges Revised 10/30/12 Page 1/4 ...PLANNING GUIDE Product Dimensions All tolerances ±1/16" (±1.6 mm) unless otherwise noted. Models DR30EIS and DR30EIFS are not compatible with Dacor raised vent models ERV3015. Contact your local building department for compatibility Dimension DR30ES DR30EIS A 46 1/8" (117.2 cm) B 27 3/4" (70.5 cm) C 25 3/8" (64...
... and DR30EFS are compatible with a raised vent. Use only theses specified raised vent models. www.dacor.com Phone: (800) 793-0093 DR30ES, DR30EFS, DR30EIS, DR30EIFS Document # PG05-008 Distinctive™ 30" Wide Electric Ranges Revised 10/30/12 Page 1/4 ...PLANNING GUIDE Product Dimensions All tolerances ±1/16" (±1.6 mm) unless otherwise noted. Models DR30EIS and DR30EIFS are not compatible with Dacor raised vent models ERV3015. Contact your local building department for compatibility Dimension DR30ES DR30EIS A 46 1/8" (117.2 cm) B 27 3/4" (70.5 cm) C 25 3/8" (64...
Planning Guides
Page 2
... DR30EIFS 130" (76.2 cm) min. If installing range hood, check the hood specifications for service and remain connected to bottom of unprotected wood or metal cabinet. www.dacor.com Phone: (800) 793-0093 In addition, the junction box/receptacle must be reduced by not ... all instances, installation of burns or fire by reaching over heated surface units, cabinet storage space located above range (both sides). DR30ES, DR30EFS, DR30EIS, DR30EIFS Document # PG05-008 Distinctive 30" Wide Electric Ranges Revised 10/30/12 Page 2/4 PLANNING GUIDE All tolerances +1/16" (+1.6 mm), -0 unless...
... DR30EIFS 130" (76.2 cm) min. If installing range hood, check the hood specifications for service and remain connected to bottom of unprotected wood or metal cabinet. www.dacor.com Phone: (800) 793-0093 In addition, the junction box/receptacle must be reduced by not ... all instances, installation of burns or fire by reaching over heated surface units, cabinet storage space located above range (both sides). DR30ES, DR30EFS, DR30EIS, DR30EIFS Document # PG05-008 Distinctive 30" Wide Electric Ranges Revised 10/30/12 Page 2/4 PLANNING GUIDE All tolerances +1/16" (+1.6 mm), -0 unless...
Planning Guides
Page 3
..., 3" Side Panels Removed * To create a "built-in Canada come pre-wired with a 4 wire appliance cord and NEMA 14-50P plug. www.dacor.com Phone: (800) 793-0093 DR30ES, DR30EFS, DR30EIS, DR30EIFS Document # PG05-008 Distinctive 30" Wide Electric Ranges Revised 10/30/12 Page 3/4 PLANNING GUIDE 10" (25.4 cm) 10" (25.4 cm).... 11.94kW (49.75 Amp.) *Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground. **This information above is for models DR30EIS and DR30EIFS with side panels behind range NEMA 14-50P Plug NEMA 14-50R Receptacle Self-Rimming Installation Cutout Options (Models...
..., 3" Side Panels Removed * To create a "built-in Canada come pre-wired with a 4 wire appliance cord and NEMA 14-50P plug. www.dacor.com Phone: (800) 793-0093 DR30ES, DR30EFS, DR30EIS, DR30EIFS Document # PG05-008 Distinctive 30" Wide Electric Ranges Revised 10/30/12 Page 3/4 PLANNING GUIDE 10" (25.4 cm) 10" (25.4 cm).... 11.94kW (49.75 Amp.) *Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground. **This information above is for models DR30EIS and DR30EIFS with side panels behind range NEMA 14-50P Plug NEMA 14-50R Receptacle Self-Rimming Installation Cutout Options (Models...
Planning Guides
Page 4
... Wide Electric Ranges Revised 10/30/12 Page 4/4 PLANNING GUIDE All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. ■■ Only models DR30EIS and DR30EIFS may be installed with a raised vent. Countertop front 29 1/4" (74.3 cm) countertop opening 30 1/16" (76.2 cm) cabinet opening below countertop... vent overlaps the countertop in look where the range trim overlaps the countertop on countertop Countertop 24 3/8" (61.9 cm) max. www.dacor.com Phone: (800) 793-0093 Downdraft ERV30[15] with Slide-In, Self-Rimming Installation using 3" Side Panels Removed * To create...
... Wide Electric Ranges Revised 10/30/12 Page 4/4 PLANNING GUIDE All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. ■■ Only models DR30EIS and DR30EIFS may be installed with a raised vent. Countertop front 29 1/4" (74.3 cm) countertop opening 30 1/16" (76.2 cm) cabinet opening below countertop... vent overlaps the countertop in look where the range trim overlaps the countertop on countertop Countertop 24 3/8" (61.9 cm) max. www.dacor.com Phone: (800) 793-0093 Downdraft ERV30[15] with Slide-In, Self-Rimming Installation using 3" Side Panels Removed * To create...
Installation Instructions
Page 1
B Installation Instructions Distinctive™ Electric Range Models: DR30ES, DR30EIS, DR30EFS and DR30EIFS Part No. 105906 Rev.
B Installation Instructions Distinctive™ Electric Range Models: DR30ES, DR30EIS, DR30EFS and DR30EIFS Part No. 105906 Rev.
Installation Instructions
Page 2
... Important Safety Instructions 1 Important Information About Safety Instructions 1 Safety Symbols in U.S.A. Leave these installation instructions with flashlight) Model Identification DR30EIFS-C SIZE (inches) TRIM TYPE I = Slide-in trim No character = Freestanding HANDLE TYPE F = Flush handle, integrated in... label (view through the grill below the control panel, on the product data label. Pacific Time Web site: www.dacor.com Dacor Distinctive Service (for changes to change without notice. Customer Service Information If You Need Help... If you begin the installation...
... Important Safety Instructions 1 Important Information About Safety Instructions 1 Safety Symbols in U.S.A. Leave these installation instructions with flashlight) Model Identification DR30EIFS-C SIZE (inches) TRIM TYPE I = Slide-in trim No character = Freestanding HANDLE TYPE F = Flush handle, integrated in... label (view through the grill below the control panel, on the product data label. Pacific Time Web site: www.dacor.com Dacor Distinctive Service (for changes to change without notice. Customer Service Information If You Need Help... If you begin the installation...
Installation Instructions
Page 6
... a backguard on models DR30ES and DR30EFS are compatible with a flat stainless trim piece in place of a backguard. Models DR30EIS and DR30EIFS are not compatible with a raised vent. Use only theses specified raised vent models. 4 The trim on models... ADRB30E06 ADRB30E09 3 Inch 6 Inch 9 Inch Optional on all models Standard on models DR30ES, DR30EFS Optional on models DR30EIS, DR30EIFS Optional on all models **Models DR30EIS and DR30EIFS come equipped from the factory with Dacor raised vent models ERV30 and ERV3015. A backguard may be purchased as an optional accessory.
... a backguard on models DR30ES and DR30EFS are compatible with a flat stainless trim piece in place of a backguard. Models DR30EIS and DR30EIFS are not compatible with a raised vent. Use only theses specified raised vent models. 4 The trim on models... ADRB30E06 ADRB30E09 3 Inch 6 Inch 9 Inch Optional on all models Standard on models DR30ES, DR30EFS Optional on models DR30EIS, DR30EIFS Optional on all models **Models DR30EIS and DR30EIFS come equipped from the factory with Dacor raised vent models ERV30 and ERV3015. A backguard may be purchased as an optional accessory.
Installation Instructions
Page 8
...30 1/16" (76.2 cm) cabinet opening below countertop Notch countertop to width of the countertop. This configuration is only for models DR30EIS and DR30EIFS with the width at the notches remaining 30 1/16". Countertop thickness: 1 5/8" (4.1 cm) max. • On self-rimming ...Rear wall or countertop edge 3/8" min. (9.5 mm) countertop overhang 24 1/2" (62.2 cm) max. Installation Specifications Self-Rimming Installation Cutout Options (Models DR30EIS and DR30EIFS Only) Countertop height: 34 3/4" (88.3 cm) min. • 36 7/8" (93.7 cm) max. Slide-In, Self-Rimming Installation, 3" ...
...30 1/16" (76.2 cm) cabinet opening below countertop Notch countertop to width of the countertop. This configuration is only for models DR30EIS and DR30EIFS with the width at the notches remaining 30 1/16". Countertop thickness: 1 5/8" (4.1 cm) max. • On self-rimming ...Rear wall or countertop edge 3/8" min. (9.5 mm) countertop overhang 24 1/2" (62.2 cm) max. Installation Specifications Self-Rimming Installation Cutout Options (Models DR30EIS and DR30EIFS Only) Countertop height: 34 3/4" (88.3 cm) min. • 36 7/8" (93.7 cm) max. Slide-In, Self-Rimming Installation, 3" ...
Installation Instructions
Page 9
...61.9 cm) max. The rear range trim will stop when Countertop thickness: 1 5/8" (4.1 cm) max. This configuration is required for models DR30EIS and DR30EIFS with side panels behind door removed. 7 Downdraft ERV30[15] with Slide-In, Self-Rimming Installation, 3" Side Panels Removed * To create a... "built-in back. Installation Specifications Self-Rimming Installation with Raised Vent Cutout Options (Models DR30EIS and DR30EIFS Only) Countertop height: 34 3/4" (88.3 cm) min. • A self-rimming countertop configuration is only for raised vent ...
...61.9 cm) max. The rear range trim will stop when Countertop thickness: 1 5/8" (4.1 cm) max. This configuration is required for models DR30EIS and DR30EIFS with side panels behind door removed. 7 Downdraft ERV30[15] with Slide-In, Self-Rimming Installation, 3" Side Panels Removed * To create a... "built-in back. Installation Specifications Self-Rimming Installation with Raised Vent Cutout Options (Models DR30EIS and DR30EIFS Only) Countertop height: 34 3/4" (88.3 cm) min. • A self-rimming countertop configuration is only for raised vent ...
Use & Care Manuals
Page 1
Use and Care Manual Distinctive™ Electric Range Models: DR30ES, DR30EIS, DR30EFS and DR30EIFS Style varies, model DR30ES shown Ta b le o f C o nt e nt s Important Safety Instructions 1 Getting to Know Your Range 4 Operating the Cooktop 7 Operating the Oven 10 Care and Cleaning 22 Parts and Accessories 27 Before You Call for Service 27 Warranty and Service 29 Warranty Card Back Cover Part No. 105907 Rev B
Use and Care Manual Distinctive™ Electric Range Models: DR30ES, DR30EIS, DR30EFS and DR30EIFS Style varies, model DR30ES shown Ta b le o f C o nt e nt s Important Safety Instructions 1 Getting to Know Your Range 4 Operating the Cooktop 7 Operating the Oven 10 Care and Cleaning 22 Parts and Accessories 27 Before You Call for Service 27 Warranty and Service 29 Warranty Card Back Cover Part No. 105907 Rev B
Combined Configuration
Page 1
... chassis to width of the DR30DI range and ERV3015 raised vent create a "built-in back. This configuration is required for models DR30EIS and DR30EIFS with Slide-In, Self-Rimming Installation using 3" Side Panels Installed 10" min. (25.4 cm) to any combustibles above counter ... (1.0 cm) space required behind ERV3015 chassis to 22 3/4" (57.8 cm) ERV3015 raised vent 3/8" min. (1.0 cm) space required behind door removed. www.dacor.com Phone: (800) 793-0093 Countertop front 29 1/4" (74.3 cm) countertop opening 30 1/16" (76.2 cm) cabinet opening below countertop Notch countertop ...
... chassis to width of the DR30DI range and ERV3015 raised vent create a "built-in back. This configuration is required for models DR30EIS and DR30EIFS with Slide-In, Self-Rimming Installation using 3" Side Panels Installed 10" min. (25.4 cm) to any combustibles above counter ... (1.0 cm) space required behind ERV3015 chassis to 22 3/4" (57.8 cm) ERV3015 raised vent 3/8" min. (1.0 cm) space required behind door removed. www.dacor.com Phone: (800) 793-0093 Countertop front 29 1/4" (74.3 cm) countertop opening 30 1/16" (76.2 cm) cabinet opening below countertop Notch countertop ...