Planning Guides
Page 1
....6 cm) 8" (20,3 cm) round exhausts with all Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be installed in accordance with IVS2 and IVSR2 (sold separately) Model No. IVS1 IVSR1 IVS2 IVSR2 Dedicated Circuit Required 120 Vac, 60 Hz., 15 Amp. ...Specifications subject to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093 7.7 Install all...
....6 cm) 8" (20,3 cm) round exhausts with all Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be installed in accordance with IVS2 and IVSR2 (sold separately) Model No. IVS1 IVSR1 IVS2 IVSR2 Dedicated Circuit Required 120 Vac, 60 Hz., 15 Amp. ...Specifications subject to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093 7.7 Install all...
Installation Instructions
Page 1
Installation Instructions Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Part No. 65278 Rev. H
Installation Instructions Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Part No. 65278 Rev. H
Installation Instructions
Page 5
... 60 Hz., 15 Amp. Requirements* grounded , dedicated circuit IVS1: 0.2 kW (2 Amp.) Total Connected Load* IVS2: 0.4 kW (3 Amp.) IVSR1/IVSR2 0.2 kW (1.5 Amp.) plus the power requirements of the IVS within a combustible or noncombustible hood canopy. Make sure that all instructions and warnings ...remote blower connected. Min. IVS1: 600 CFM, IVS2: 1200 CFM Blower Rating** IVSR1 and IVSR2: Dependant on the unit for exact specifications. ** At zero inches static pressure The Dacor Integrated Ventilation System (IVS) is designed for installation inside custom hood canopies. Product ...
... 60 Hz., 15 Amp. Requirements* grounded , dedicated circuit IVS1: 0.2 kW (2 Amp.) Total Connected Load* IVS2: 0.4 kW (3 Amp.) IVSR1/IVSR2 0.2 kW (1.5 Amp.) plus the power requirements of the IVS within a combustible or noncombustible hood canopy. Make sure that all instructions and warnings ...remote blower connected. Min. IVS1: 600 CFM, IVS2: 1200 CFM Blower Rating** IVSR1 and IVSR2: Dependant on the unit for exact specifications. ** At zero inches static pressure The Dacor Integrated Ventilation System (IVS) is designed for installation inside custom hood canopies. Product ...
Installation Instructions
Page 6
... required. Even small differences between blower air flow rates can greatly reduce the air draw by the hood. • When installing models IVSR1 and IVSR2, DO NOT install more than one external blower to increase the length of the duct run . Where turns are minimum clearances, unless...a minimum of 36" (914mm) above the appliance cooking surface. • An IVS installed in a custom hood canopy that is constructed with a Dacor IHL series stainless steel hood liner must be installed with the non-combustible material structure a minimum of 30" (762mm) above the appliance cooking surface. ...
... required. Even small differences between blower air flow rates can greatly reduce the air draw by the hood. • When installing models IVSR1 and IVSR2, DO NOT install more than one external blower to increase the length of the duct run . Where turns are minimum clearances, unless...a minimum of 36" (914mm) above the appliance cooking surface. • An IVS installed in a custom hood canopy that is constructed with a Dacor IHL series stainless steel hood liner must be installed with the non-combustible material structure a minimum of 30" (762mm) above the appliance cooking surface. ...
Installation Instructions
Page 7
The IVS comes equipped with model and configuration. The maximum straight duct length for Models IVSR1 and IVSR2: Models IVSR1 and IVSR2 are used . Additional Requirements for the hood is determined by the type of duct used , try to keep a minimum of 24 inches of roof and ... Duct Work Equivalent Lengths 2" (5.1 cm) 13" (33.0 cm) 21" (53.3 cm) Transition Model ATD10 8" (20.3 cm) • Do not rely on 10 inch duct using Dacor transition ATD10. 3¼" X 10" rectangular 50 feet For each elbow and transition added to the duct work, a certain number of transitions and turns to as...
The IVS comes equipped with model and configuration. The maximum straight duct length for Models IVSR1 and IVSR2: Models IVSR1 and IVSR2 are used . Additional Requirements for the hood is determined by the type of duct used , try to keep a minimum of 24 inches of roof and ... Duct Work Equivalent Lengths 2" (5.1 cm) 13" (33.0 cm) 21" (53.3 cm) Transition Model ATD10 8" (20.3 cm) • Do not rely on 10 inch duct using Dacor transition ATD10. 3¼" X 10" rectangular 50 feet For each elbow and transition added to the duct work, a certain number of transitions and turns to as...
Installation Instructions
Page 8
...GREEN Not used is capable of the electrical access holes in the cutout and the duct work is installed. 1. If installing a hood liner (Dacor series IHL) install it to the hood, make sure there are no obstructions that power to secure the connections. 6 Remove the filters from...• Do not ground the hood to the junction box. 4. Fasten all duct joints with duct tape or certified silver tape. Models IVSR1 and IVSR2 only: Route the wiring from the power source wiring. Observe the specifications on the top of the hood electrical wiring may create an electric ...
...GREEN Not used is capable of the electrical access holes in the cutout and the duct work is installed. 1. If installing a hood liner (Dacor series IHL) install it to the hood, make sure there are no obstructions that power to secure the connections. 6 Remove the filters from...• Do not ground the hood to the junction box. 4. Fasten all duct joints with duct tape or certified silver tape. Models IVSR1 and IVSR2 only: Route the wiring from the power source wiring. Observe the specifications on the top of the hood electrical wiring may create an electric ...
Installation Instructions
Page 10
Wiring Diagrams GROUND NEUTRAL LINE WH BLK LAMP DIMMER BLK BLK HALOGEN LIGHTS (2) WH BLK FAN MOTOR M WH FAN SWITCH IVS1, IVSR1 GROUND NEUTRAL LINE WH BLK LAMP DIMMER WH BLK BLK BLK HALOGEN LIGHTS (3) WH BLK FAN MOTORS M M IVS2, IVSR2 FAN SWITCH 8
Wiring Diagrams GROUND NEUTRAL LINE WH BLK LAMP DIMMER BLK BLK HALOGEN LIGHTS (2) WH BLK FAN MOTOR M WH FAN SWITCH IVS1, IVSR1 GROUND NEUTRAL LINE WH BLK LAMP DIMMER WH BLK BLK BLK HALOGEN LIGHTS (3) WH BLK FAN MOTORS M M IVS2, IVSR2 FAN SWITCH 8
Use & Care Manuals
Page 1
Use and Care Manual Custom Hood Integrated Ventilation Systems For use with models: IVS1, IVSR1, IVS2 and IVSR2 SAFETY IS EVERYONE'S RESPONSIBILITY. NOTES: Contains helpful hints and tips. ALL DACOR® APPLIANCES ARE DESIGNED AND CONSTRUCTED TO GIVE YOU MANY YEARS OF SAFE OPERATION. Place Serial Number Label Here Part No. 65210 Rev. E THE...
Use and Care Manual Custom Hood Integrated Ventilation Systems For use with models: IVS1, IVSR1, IVS2 and IVSR2 SAFETY IS EVERYONE'S RESPONSIBILITY. NOTES: Contains helpful hints and tips. ALL DACOR® APPLIANCES ARE DESIGNED AND CONSTRUCTED TO GIVE YOU MANY YEARS OF SAFE OPERATION. Place Serial Number Label Here Part No. 65210 Rev. E THE...