Service Manual
Page 9
...) • Integrated SVGA-compatible ISA video subsystem attached to four Pentium Pro microprocessors. Contact Dell for the Dell PowerEdge 6100/200 system is installed) • Optional, redundant hot-pluggable power supplies • ECC feature built in a traditional personal computer, Dell PowerEdge 6100 systems include the following new and/or advanced features: • 512 KB of cache memory...
...) • Integrated SVGA-compatible ISA video subsystem attached to four Pentium Pro microprocessors. Contact Dell for the Dell PowerEdge 6100/200 system is installed) • Optional, redundant hot-pluggable power supplies • ECC feature built in a traditional personal computer, Dell PowerEdge 6100 systems include the following new and/or advanced features: • 512 KB of cache memory...
Service Manual
Page 10
... Guide" (P/N 40722). Computer Orientation NOTE: When reading the text in this manual, assume that monitors critical system volt- For information about installing the PowerEdge 6100 systems in Figure 1-1. 1-2 Dell PowerEdge 6100/200 System Service Manual For a complete list of these features are briefly described in this chapter. ages and temperatures, as well as shown in...
... Guide" (P/N 40722). Computer Orientation NOTE: When reading the text in this manual, assume that monitors critical system volt- For information about installing the PowerEdge 6100 systems in Figure 1-1. 1-2 Dell PowerEdge 6100/200 System Service Manual For a complete list of these features are briefly described in this chapter. ages and temperatures, as well as shown in...
Service Manual
Page 12
Front/Left Internal View external drive bay (4) control panel internal drive bay (6) hard-disk drive security lock air intake panel (cooling fans are located behind the air intake panel) 1-4 Dell PowerEdge 6100/200 System Service Manual memory module secondary microprocessor module or terminator module primary microprocessor module expansion slot (10) support panel system board Figure 1-3.
Front/Left Internal View external drive bay (4) control panel internal drive bay (6) hard-disk drive security lock air intake panel (cooling fans are located behind the air intake panel) 1-4 Dell PowerEdge 6100/200 System Service Manual memory module secondary microprocessor module or terminator module primary microprocessor module expansion slot (10) support panel system board Figure 1-3.
Service Manual
Page 14
keylock closeout panel or optional power supply upper SCSI connector slot keylock mouse connector keyboard connector serial port 2 connector serial port 1 connector parallel port connector video connector power supply fault indicator (red LED) online indicator (green LED) SMB connector Figure 1-5. Back Panel Features lower SCSI connector slot security cable slot 1-6 Dell PowerEdge 6100/200 System Service Manual
keylock closeout panel or optional power supply upper SCSI connector slot keylock mouse connector keyboard connector serial port 2 connector serial port 1 connector parallel port connector video connector power supply fault indicator (red LED) online indicator (green LED) SMB connector Figure 1-5. Back Panel Features lower SCSI connector slot security cable slot 1-6 Dell PowerEdge 6100/200 System Service Manual
Service Manual
Page 15
...64-, and 128-MB SIMMs up to J8 make up bank 1; A bank consists of eight SIMMS. SIMMs in different banks may differ in the Dell PowerEdge 6100/200 System Installation and Troubleshooting Guide. System Overview 1-7 or 70-ns), tin-lead alloy plated edge connector, single- All SIMMs in a bank ...PCI expansion cards the next time the system is 64 MB of 36-bit, 72-pin, fast page (60- See "SIMMs" in the Dell PowerEdge 6100/200 System User's Guide describes the system configuration utility and provides instructions for information on the memory module (see "Adding Memory" in Chapter 8,...
...64-, and 128-MB SIMMs up to J8 make up bank 1; A bank consists of eight SIMMS. SIMMs in different banks may differ in the Dell PowerEdge 6100/200 System Installation and Troubleshooting Guide. System Overview 1-7 or 70-ns), tin-lead alloy plated edge connector, single- All SIMMs in a bank ...PCI expansion cards the next time the system is 64 MB of 36-bit, 72-pin, fast page (60- See "SIMMs" in the Dell PowerEdge 6100/200 System User's Guide describes the system configuration utility and provides instructions for information on the memory module (see "Adding Memory" in Chapter 8,...
Service Manual
Page 16
...remove and insert hard-disk drives without shutting down the system. These bays can contain up to the EISA local bus. For 1-8 Dell PowerEdge 6100/200 System Service Manual Integrated SCSI Controllers Two built-in the other two bays. NOTES: The externally accessible drive bays at the ...front of the system cooling fans. In the standard Dell PowerEdge 6100 system configuration, one Ultra/Wide SCSI host adapter on the system board (see Chapter 9, "Installing Drives in the External Bays," in conjunction...
...remove and insert hard-disk drives without shutting down the system. These bays can contain up to the EISA local bus. For 1-8 Dell PowerEdge 6100/200 System Service Manual Integrated SCSI Controllers Two built-in the other two bays. NOTES: The externally accessible drive bays at the ...front of the system cooling fans. In the standard Dell PowerEdge 6100 system configuration, one Ultra/Wide SCSI host adapter on the system board (see Chapter 9, "Installing Drives in the External Bays," in conjunction...
Service Manual
Page 18
...power connectors must be hot-pluggable. NOTE: The power supply produces DC voltages only under its loaded condition. See the documentation provided with the Dell PowerEdge 6100 systems. The 50-pin SCSI cable has six connectors: • The connector at 50 or 60 Hz. Therefore, when you use only ...; The five connectors on the cable attach to the SCSI host adapter connector labeled "SCSI B" on the system board or drives. 1-10 Dell PowerEdge 6100/200 System Service Manual The power-supply paralleling board permits the power supplies to 265 VAC at the end of 90 to be connected to...
...power connectors must be hot-pluggable. NOTE: The power supply produces DC voltages only under its loaded condition. See the documentation provided with the Dell PowerEdge 6100 systems. The 50-pin SCSI cable has six connectors: • The connector at 50 or 60 Hz. Therefore, when you use only ...; The five connectors on the cable attach to the SCSI host adapter connector labeled "SCSI B" on the system board or drives. 1-10 Dell PowerEdge 6100/200 System Service Manual The power-supply paralleling board permits the power supplies to 265 VAC at the end of 90 to be connected to...
Service Manual
Page 20
... (black) common (black) +5 VDC (red) +5 VDC (red) common (black) common (black) +5 VDC (red) +5 VDC (red) common (black) Figure 1-9. DC Power Connector PWR2 and PWR3 1-12 Dell PowerEdge 6100/200 System Service Manual Figure 1-8. Pin 7 on the system board connector is not used. The thirteen remaining signals are not connected to the system board...
... (black) common (black) +5 VDC (red) +5 VDC (red) common (black) common (black) +5 VDC (red) +5 VDC (red) common (black) Figure 1-9. DC Power Connector PWR2 and PWR3 1-12 Dell PowerEdge 6100/200 System Service Manual Figure 1-8. Pin 7 on the system board connector is not used. The thirteen remaining signals are not connected to the system board...
Service Manual
Page 22
Power-Supply Paralleling Board Connectors 1-14 Dell PowerEdge 6100/200 System Service Manual share current with each other. system board connector (PWR1) peripherals connector (PWRFD) system board connector (PWR2) diagnostics port (J32) system board ...
Power-Supply Paralleling Board Connectors 1-14 Dell PowerEdge 6100/200 System Service Manual share current with each other. system board connector (PWR1) peripherals connector (PWRFD) system board connector (PWR2) diagnostics port (J32) system board ...
Service Manual
Page 24
... not supported/not used • IDE • J8G1 • HD LED 1 • J5E1 • J4G1 • I2C • HD LED 2 • J2A3 • C5B1 1-16 Dell PowerEdge 6100/200 System Service Manual
... not supported/not used • IDE • J8G1 • HD LED 1 • J5E1 • J4G1 • I2C • HD LED 2 • J2A3 • C5B1 1-16 Dell PowerEdge 6100/200 System Service Manual
Service Manual
Page 26
CLEAR PASSWORD Clears all passwords. (default) Retains all passwords. BIOS WRITE FLOPPY 0 (default) Enables BIOS update of flash memory. (Dell default) Enables 1.44-MB diskette drive size or autodetection. Disables BIOS update of flash memory. Enables recovery mode for BIOS flash memory (the BIOS WRITE ... (default) Normal BIOS boot operation. Table 1-2. Settings in CMOS and the RTC are retained during reset. Enables forced 2.88-MB diskette drive size detection. 1-18 Dell PowerEdge 6100/200 System Service Manual
CLEAR PASSWORD Clears all passwords. (default) Retains all passwords. BIOS WRITE FLOPPY 0 (default) Enables BIOS update of flash memory. (Dell default) Enables 1.44-MB diskette drive size or autodetection. Disables BIOS update of flash memory. Enables recovery mode for BIOS flash memory (the BIOS WRITE ... (default) Normal BIOS boot operation. Table 1-2. Settings in CMOS and the RTC are retained during reset. Enables forced 2.88-MB diskette drive size detection. 1-18 Dell PowerEdge 6100/200 System Service Manual
Service Manual
Page 30
... IRQ13 Used by the math coprocessor to indicate coprocessor error IRQ14 Available for use by expansion card IRQ15 Available for use by expansion card 1-22 Dell PowerEdge 6100/200 System Service Manual SCSI Backplane Board Connectors Connector Description CONTROL PANEL Control panel connector POWER Power input connector SCSI Ultra/Wide SCSI cable connector...
... IRQ13 Used by the math coprocessor to indicate coprocessor error IRQ14 Available for use by expansion card IRQ15 Available for use by expansion card 1-22 Dell PowerEdge 6100/200 System Service Manual SCSI Backplane Board Connectors Connector Description CONTROL PANEL Control panel connector POWER Power input connector SCSI Ultra/Wide SCSI cable connector...
Service Manual
Page 32
... full-length, 8- or 16-bit ISA or 32-bit EISA EISA expansion-card connector size 188 pins PCI expansion-card connector size 120 pins 1-24 Dell PowerEdge 6100/200 System Service Manual Technical Specifications Table 1-7.
... full-length, 8- or 16-bit ISA or 32-bit EISA EISA expansion-card connector size 188 pins PCI expansion-card connector size 120 pins 1-24 Dell PowerEdge 6100/200 System Service Manual Technical Specifications Table 1-7.
Service Manual
Page 34
... connectors SCSI Backplane Connectors CONTROL PANEL one 30-pin connector POWER one 16-pin connector SLOTnID=n (SCSI hard-disk drive six 80-pin connectors 1-26 Dell PowerEdge 6100/200 System Service Manual ment module MEMORY MODULE . . . Table 1-7.
... connectors SCSI Backplane Connectors CONTROL PANEL one 30-pin connector POWER one 16-pin connector SLOTnID=n (SCSI hard-disk drive six 80-pin connectors 1-26 Dell PowerEdge 6100/200 System Service Manual ment module MEMORY MODULE . . . Table 1-7.
Service Manual
Page 36
...) Vibration: Operating 0.25 G (half-sine wave) at a sweep of 3 to 300 hertz (Hz) for 15 minutes Storage 0.5 G at 3 to 300 Hz for 15 minutes z 1-28 Dell PowerEdge 6100/200 System Service Manual Table 1-7.
...) Vibration: Operating 0.25 G (half-sine wave) at a sweep of 3 to 300 hertz (Hz) for 15 minutes Storage 0.5 G at 3 to 300 Hz for 15 minutes z 1-28 Dell PowerEdge 6100/200 System Service Manual Table 1-7.
Service Manual
Page 38
... proper connectors on the back of the computer. While performing the visual inspection, make any problems? Proceed to the next section, "Observing the Boot Routine." 2-2 Dell PowerEdge 6100/200 System Service Manual To perform the external visual inspection, follow these connectors at each end of the computer, including all controls and indicators, and...
... proper connectors on the back of the computer. While performing the visual inspection, make any problems? Proceed to the next section, "Observing the Boot Routine." 2-2 Dell PowerEdge 6100/200 System Service Manual To perform the external visual inspection, follow these connectors at each end of the computer, including all controls and indicators, and...
Service Manual
Page 40
... it from their sockets or connectors. To reseat a SIMM, remove it as described in "Microprocessor and Heat Sink" in Chapter 4. 2-4 Dell PowerEdge 6100/200 System Service Manual 5. When you perform the visual inspection, refer to "System Features" in Chapter 1 to the source of each power... and exited all power supplies must have either a power supply or the power closeout panel installed. Observe the monitor screen for the Dell Server Assistant main menu. See "Running the System Diagnostics" found later in the inspection procedure. No. Proceed to avoid electrical shock....
... it from their sockets or connectors. To reseat a SIMM, remove it as described in "Microprocessor and Heat Sink" in Chapter 4. 2-4 Dell PowerEdge 6100/200 System Service Manual 5. When you perform the visual inspection, refer to "System Features" in Chapter 1 to the source of each power... and exited all power supplies must have either a power supply or the power closeout panel installed. Observe the monitor screen for the Dell Server Assistant main menu. See "Running the System Diagnostics" found later in the inspection procedure. No. Proceed to avoid electrical shock....
Service Manual
Page 42
...running the diagnostics program, make a blank, formatted diskette to be inserted in the system diagnostics reveals the source of the problem or leads to the Dell Server Assistant menu: • Run All Tests - Getting Help If none of the system • Run Quick Tests - For instructions, see ... or exit to MS-DOS, which returns to the proper troubleshooting steps for determining the source of the problem, call Dell for technical assistance. See Chapter 5, "Running the System Diagnostics," in the Installation and Troubleshooting Guide. 2-6 Dell PowerEdge 6100/200 System Service Manual
...running the diagnostics program, make a blank, formatted diskette to be inserted in the system diagnostics reveals the source of the problem or leads to the Dell Server Assistant menu: • Run All Tests - Getting Help If none of the system • Run Quick Tests - For instructions, see ... or exit to MS-DOS, which returns to the proper troubleshooting steps for determining the source of the problem, call Dell for technical assistance. See Chapter 5, "Running the System Diagnostics," in the Installation and Troubleshooting Guide. 2-6 Dell PowerEdge 6100/200 System Service Manual
Service Manual
Page 44
... It 0070 CMOS Time & Date Not Set 0080 Option ROM has bad checksum 0083 Shadow of PCI ROM Failed 0084 Shadow of EISA ROM Failed 3-2 Dell PowerEdge 6100/200 System Service Manual Code 0002 Table 3-2.
... It 0070 CMOS Time & Date Not Set 0080 Option ROM has bad checksum 0083 Shadow of PCI ROM Failed 0084 Shadow of EISA ROM Failed 3-2 Dell PowerEdge 6100/200 System Service Manual Code 0002 Table 3-2.
Service Manual
Page 50
... any static charge from ESD. face, such as a part of electrical shock, a trained service technician must disconnect all power supply cables before servicing the system. 4-2 Dell PowerEdge 6100/200 System Service Manual WARNING: This system may have more than one power supply cable. Disconnect any attached peripherals. 2. Precautionary Measures Before you start to...
... any static charge from ESD. face, such as a part of electrical shock, a trained service technician must disconnect all power supply cables before servicing the system. 4-2 Dell PowerEdge 6100/200 System Service Manual WARNING: This system may have more than one power supply cable. Disconnect any attached peripherals. 2. Precautionary Measures Before you start to...