Product Specifications Sheet (English)
Page 1
Ft. NOTE: Always consult local and / or national electric codes. Refer to change. 1Fastest time based on smallest load / Fast Dry cycle selected for detailed installation instructions on manufacturer specifications....exclusive 4-way venting system is easy to Center of the industry's longest dryer vent runs. 27" ELECTRIC FRONT LOAD DRYERS Capacity IEC NSF® Certified 8.0 Cu. Wall Ovens Warmer Drawers Cooktops Built-In Ranges Freestanding Ranges Microwaves Electric Front Load Dryers EIED55H MB, EIED55H IW Featuring IQ-Touch™ Electronic Controls Mediterranean ...
Ft. NOTE: Always consult local and / or national electric codes. Refer to change. 1Fastest time based on smallest load / Fast Dry cycle selected for detailed installation instructions on manufacturer specifications....exclusive 4-way venting system is easy to Center of the industry's longest dryer vent runs. 27" ELECTRIC FRONT LOAD DRYERS Capacity IEC NSF® Certified 8.0 Cu. Wall Ovens Warmer Drawers Cooktops Built-In Ranges Freestanding Ranges Microwaves Electric Front Load Dryers EIED55H MB, EIED55H IW Featuring IQ-Touch™ Electronic Controls Mediterranean ...
Product Specifications Sheet (English)
Page 2
... install in . in the U.S.A. Do NOT install on carpeted surface. • Dryer MUST exhaust to Built-In Installations on web. Optional Accessories • Drawer Pedestals - Electrolux Major Appliances, N.A. We reserve the right to 53". Electric Front Load Dryers EIED55H MB, EIED55H IW Front 27" 31 1/2"* Left 50 5/8"* Reversible Door Swing Rear 38" (53" with pedestal...
... install in . in the U.S.A. Do NOT install on carpeted surface. • Dryer MUST exhaust to Built-In Installations on web. Optional Accessories • Drawer Pedestals - Electrolux Major Appliances, N.A. We reserve the right to 53". Electric Front Load Dryers EIED55H MB, EIED55H IW Front 27" 31 1/2"* Left 50 5/8"* Reversible Door Swing Rear 38" (53" with pedestal...
Installation Instructions (All Languages)
Page 5
...materials. The gas supply line should be constructed of your dryer to or less than 1/2 psig (3.45 kPa). 8. The tubing MUST be 1/2 inch (1.27 cm) pipe. 3. The dryer MUST be used to connect your dryer. plugged tapping, accessible for proper and safe operation of ...stainless steel or plastic-coated brass. 4. When the dryer stops, the dampers automatically close to the dryer. 6. These conditions will corrode when...
...materials. The gas supply line should be constructed of your dryer to or less than 1/2 psig (3.45 kPa). 8. The tubing MUST be 1/2 inch (1.27 cm) pipe. 3. The dryer MUST be used to connect your dryer. plugged tapping, accessible for proper and safe operation of ...stainless steel or plastic-coated brass. 4. When the dryer stops, the dampers automatically close to the dryer. 6. These conditions will corrode when...
Installation Instructions (All Languages)
Page 6
...REQUIREMENTS on the screws or rivets, clogging the duct work and creating a fire hazard as well as increase drying times. A clothes dryer produces combustible lint. Lint can become caught in the screen, on the next page. Number of 90° turns MAXIMUM LENGTH of elbows ... HOOD TYPE (Preferred) 4" (10.2cm) louvered 2.5" (6.35cm) 0 125 ft. (38.10m) 110 ft. (33.53m) 1 115 ft. (35.05m) 100 ft. (30.48m) 2 105 ft. (32.00m) 90 ft. (27.43m) 3 95 ft. (28.96m) 80 ft. (24.38m) 4 85 ft. (25.91m) 70 ft. (21.34m) WARNING FIRE HAZARD • Do not install flexible ...
...REQUIREMENTS on the screws or rivets, clogging the duct work and creating a fire hazard as well as increase drying times. A clothes dryer produces combustible lint. Lint can become caught in the screen, on the next page. Number of 90° turns MAXIMUM LENGTH of elbows ... HOOD TYPE (Preferred) 4" (10.2cm) louvered 2.5" (6.35cm) 0 125 ft. (38.10m) 110 ft. (33.53m) 1 115 ft. (35.05m) 100 ft. (30.48m) 2 105 ft. (32.00m) 90 ft. (27.43m) 3 95 ft. (28.96m) 80 ft. (24.38m) 4 85 ft. (25.91m) 70 ft. (21.34m) WARNING FIRE HAZARD • Do not install flexible ...
Installation Instructions (All Languages)
Page 9
... venting of exhaust on pedestal-mounted dryer adds approximately 1.7 in. (4.3 cm) to installation depth. 13.50" (34.5cm) to center of rear vent 50.6" (128.5cm)* to clear open door 31.50" (80cm)* to front of closed door 27.00" (68.5cm) electrical supply on rear of unit centerline height...75" (192.5cm) gas supply pipe on rear of gas unit 39.00" (99cm) electrical supply on rear of unit centerline height for rear vent 41.00" (104cm) * To obtain these minimal depth dimensions, dryer must either be vented straight back or with a quick-turn 90° elbow. Installation Requirements ...
... venting of exhaust on pedestal-mounted dryer adds approximately 1.7 in. (4.3 cm) to installation depth. 13.50" (34.5cm) to center of rear vent 50.6" (128.5cm)* to clear open door 31.50" (80cm)* to front of closed door 27.00" (68.5cm) electrical supply on rear of unit centerline height...75" (192.5cm) gas supply pipe on rear of gas unit 39.00" (99cm) electrical supply on rear of unit centerline height for rear vent 41.00" (104cm) * To obtain these minimal depth dimensions, dryer must either be vented straight back or with a quick-turn 90° elbow. Installation Requirements ...
Installation Instructions (All Languages)
Page 14
...fied gas technician. 2. Manual Shutoff Flare Valve Union GAS FLOW Flare Union Closed Nipple Open Flexible Connector Inlet Pipe on Back of the dryer. Open the shutoff valve in a location that is not available, test all pipe connections. Check for gas leaks with a manometer. gas service...to 0.96 cm) reducer for gas to the gas shutoff valve. Use a 1/2 inch to 3/8 inch (1.27 cm to dryer Shutoff Valve Open position from gas supply line to the corrosive action of the dryer. If a manometer is resistant to the 3/8 inch (0.96 cm) pipe located on the back of lique...
...fied gas technician. 2. Manual Shutoff Flare Valve Union GAS FLOW Flare Union Closed Nipple Open Flexible Connector Inlet Pipe on Back of the dryer. Open the shutoff valve in a location that is not available, test all pipe connections. Check for gas leaks with a manometer. gas service...to 0.96 cm) reducer for gas to the gas shutoff valve. Use a 1/2 inch to 3/8 inch (1.27 cm to dryer Shutoff Valve Open position from gas supply line to the corrosive action of the dryer. If a manometer is resistant to the 3/8 inch (0.96 cm) pipe located on the back of lique...