Complete Owner's Guide (English)
Page 1
B (1202) Use & Care Guide 30"/36" Induction Cooktop 318205606 Rev.
B (1202) Use & Care Guide 30"/36" Induction Cooktop 318205606 Rev.
Complete Owner's Guide (English)
Page 13
... using . Figure 1 - 30" Cooktop Figure 2 - 36" Cooktop To be relatively quiet. When you are made of noise from the induction process. One or two cooking zones are available: • The 30" cooktop is equipped with 4 cooking zones within 2 sections. • The 36" cooktop is equipped with only one has already.... If you use more than the number of induction generators. Even the highest quality cookware is vulnerable to warping. • Riveted handles on cookware can vibrate on an empty pan. Note that on the 36" cooktop the left cooking zone has its own section and...
... using . Figure 1 - 30" Cooktop Figure 2 - 36" Cooktop To be relatively quiet. When you are made of noise from the induction process. One or two cooking zones are available: • The 30" cooktop is equipped with 4 cooking zones within 2 sections. • The 36" cooktop is equipped with only one has already.... If you use more than the number of induction generators. Even the highest quality cookware is vulnerable to warping. • Riveted handles on cookware can vibrate on an empty pan. Note that on the 36" cooktop the left cooking zone has its own section and...
Installation Instructions (English Español Français)
Page 1
... allow space for installation of the junction box on the wall at the back of this or any sealant along the perimeter. INDUCTION COOKTOP INSTALLATION INSTRUCTIONS United States INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. WIDTH 21¾ (55.2) 21¾... the armored cable opening to clear the electric cable and English - Français - Min. Max. WIDTH 30¾ (78.1) 36¾ (93.3) COOKTOP DIMENSIONS B. Cooktop Dimensions Cooktop Cutout Dimensions 4" X 8" (10.2 cm x 20.3 cm) opening to route armored cable if a panel is 30" (76.2 ...
... allow space for installation of the junction box on the wall at the back of this or any sealant along the perimeter. INDUCTION COOKTOP INSTALLATION INSTRUCTIONS United States INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. WIDTH 21¾ (55.2) 21¾... the armored cable opening to clear the electric cable and English - Français - Min. Max. WIDTH 30¾ (78.1) 36¾ (93.3) COOKTOP DIMENSIONS B. Cooktop Dimensions Cooktop Cutout Dimensions 4" X 8" (10.2 cm x 20.3 cm) opening to route armored cable if a panel is 30" (76.2 ...
Installation Instructions (English Español Français)
Page 2
INDUCTION COOKTOP INSTALLATION INSTRUCTIONS Overhead Cabinet Should Not Exceed a Maximum Depth of burns or fire by reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. L Min. COUNTERTOP CUTOUT OPENING CAUTION To eliminate the risk of 13" (33 cm) 30" (76.2 cm) Min. MODEL 30" 36" J 2" (5.1cm) 2" (5.1cm) K 1 1/2" (3.8cm) 2" (5.1cm...
INDUCTION COOKTOP INSTALLATION INSTRUCTIONS Overhead Cabinet Should Not Exceed a Maximum Depth of burns or fire by reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. L Min. COUNTERTOP CUTOUT OPENING CAUTION To eliminate the risk of 13" (33 cm) 30" (76.2 cm) Min. MODEL 30" 36" J 2" (5.1cm) 2" (5.1cm) K 1 1/2" (3.8cm) 2" (5.1cm...
Installation Instructions (English Español Français)
Page 3
...necessary. 4. Electrical Requirements Observe all governing codes and ordinances. 4. The junction box should be moved if servicing is required for 36" models and 40 Amp for joining copper and aluminum wires in accordance with the National Electrical Code ANSI/NFPA No. 70-...sure your Use and Care Guide for future reference. DO NOT ground to the Installer 1. INDUCTION COOKTOP INSTALLATION INSTRUCTIONS Important Notes to a gas supply pipe. Unpack and visually inspect the cooktop. 2. Connect the ground wire before connecting the electrical supply to the Consumer Keep these ...
...necessary. 4. Electrical Requirements Observe all governing codes and ordinances. 4. The junction box should be moved if servicing is required for 36" models and 40 Amp for joining copper and aluminum wires in accordance with the National Electrical Code ANSI/NFPA No. 70-...sure your Use and Care Guide for future reference. DO NOT ground to the Installer 1. INDUCTION COOKTOP INSTALLATION INSTRUCTIONS Important Notes to a gas supply pipe. Unpack and visually inspect the cooktop. 2. Connect the ground wire before connecting the electrical supply to the Consumer Keep these ...
Installation Instructions (English Español Français)
Page 7
... mounting brackets. TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE 7 Cabinet side filler height should allow for installation of approved cooktop models See Note 1 36" Min. (91.4 cm) Min. 208/240 Volt junction box for dimensions). Approx. ... Figure below. Figure 10- Approved cooktops and built-in ovens are necessary to the cabinet (s) by 1" (2.5cm) Use 3/4" (1.9 cm) plywood, installed on two runners, flush with toe plate. INDUCTION COOKTOP INSTALLATION INSTRUCTIONS For typical under counter ...
... mounting brackets. TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE 7 Cabinet side filler height should allow for installation of approved cooktop models See Note 1 36" Min. (91.4 cm) Min. 208/240 Volt junction box for dimensions). Approx. ... Figure below. Figure 10- Approved cooktops and built-in ovens are necessary to the cabinet (s) by 1" (2.5cm) Use 3/4" (1.9 cm) plywood, installed on two runners, flush with toe plate. INDUCTION COOKTOP INSTALLATION INSTRUCTIONS For typical under counter ...