FE 192,196,199 C Users Manual
Page 7
Contents (continued) Triggering on Video Signals 59 Triggering on Pulses ...61 6 Using Memory, PC and Printer 65 Saving and Recalling ...65 Documenting Screens...69 7 Tips ...73 Using the Standard Accessories ...
Contents (continued) Triggering on Video Signals 59 Triggering on Pulses ...61 6 Using Memory, PC and Printer 65 Saving and Recalling ...65 Documenting Screens...69 7 Tips ...73 Using the Standard Accessories ...
FE 192,196,199 C Users Manual
Page 51
.... This way you could use Pulse Triggering to trigger and capture 100 intermittent glitches or you can also replay the stored screens continuously, like playing a video tape. Replaying Continuously You can leave the test tool unattended to capture 100 UPS startups. Wait until the screen with the capability of interest appears...
.... This way you could use Pulse Triggering to trigger and capture 100 intermittent glitches or you can also replay the stored screens continuously, like playing a video tape. Replaying Continuously You can leave the test tool unattended to capture 100 UPS startups. Wait until the screen with the capability of interest appears...
FE 192,196,199 C Users Manual
Page 59
... About this Chapter This chapter provides an introduction to the trigger functions of the four manual trigger functions: • Edge triggering • External triggering • Video triggering • Pulse Width triggering 51
... About this Chapter This chapter provides an introduction to the trigger functions of the four manual trigger functions: • Edge triggering • External triggering • Video triggering • Pulse Width triggering 51
FE 192,196,199 C Users Manual
Page 67
... to allow further selection of the video signal you are now fixed. Triggering on Video Signals To trigger on a video signal, first select the standard of specific video trigger settings: 5 Select positive signal polarity for video signals with negative going to measure: 1 Apply a video signal to open the Trigger on Video Signals 3 Open the Trigger Options menu...
... to allow further selection of the video signal you are now fixed. Triggering on Video Signals To trigger on a video signal, first select the standard of specific video trigger settings: 5 Select positive signal polarity for video signals with negative going to measure: 1 Apply a video signal to open the Trigger on Video Signals 3 Open the Trigger Options menu...
FE 192,196,199 C Users Manual
Page 68
...The screen is updated with the signal of line 123 is displayed on the screen. The signal of line 123. 60 To view a specific video line in more detail, you can select the line number. Observe that the status line now also shows the selected line number. The signal...half of one line is displayed on the screen. Fluke 192B - 196B/C - 199B/C Users Manual Triggering on Video Frames Use FIELD 1 or FIELD 2 to measure on video line 123, continue from step 6 as follows: 7 Enable video line selection. 8 Select number 123. Triggering on Video Lines Use ALL LINES to trigger on all line...
...The screen is updated with the signal of line 123 is displayed on the screen. The signal of line 123. 60 To view a specific video line in more detail, you can select the line number. Observe that the status line now also shows the selected line number. The signal...half of one line is displayed on the screen. Fluke 192B - 196B/C - 199B/C Users Manual Triggering on Video Frames Use FIELD 1 or FIELD 2 to measure on video line 123, continue from step 6 as follows: 7 Enable video line selection. 8 Select number 123. Triggering on Video Lines Use ALL LINES to trigger on all line...
FE 192,196,199 C Users Manual
Page 69
... open the Trigger on A... Detecting Narrow Pulses To set the test tool to trigger on narrow positive pulses shorter than 5 ms, do the following: 1 Apply a video signal to the red input A. 2 Display the TRIGGER key labels. 3 Open the Trigger Options menu. 5 Triggering on Waveforms Triggering on Pulses 4 Select Pulse Width on...
... open the Trigger on A... Detecting Narrow Pulses To set the test tool to trigger on narrow positive pulses shorter than 5 ms, do the following: 1 Apply a video signal to the red input A. 2 Display the TRIGGER key labels. 3 Open the Trigger Options menu. 5 Triggering on Waveforms Triggering on Pulses 4 Select Pulse Width on...
FE 192,196,199 C Users Manual
Page 105
..............1 division 200 MHz (FLUKE 199B/C 1 division 250 MHz (FLUKE 199B/C 2 divisions 100 MHz (FLUKE 196B/C 1 division 150 MHz (FLUKE 196B/C 2 divisions 60 MHz (FLUKE 192B 1 division 100 MHz (FLUKE 192B 2 divisions Isolated ...External Trigger Bandwidth 10 kHz Modes Automatic, Edge Trigger Levels (DC to 120 s/div......... displays glitches as fast as 50 ns Waveform Display A, B, A+B, A-B, A*B, A vs B Normal, Average (2,4,8,64 x), Persistence Time Base Accuracy 100 ppm + 0.04 div) Trigger and Delay Trigger Modes Automatic, Edge, External, Video...
..............1 division 200 MHz (FLUKE 199B/C 1 division 250 MHz (FLUKE 199B/C 2 divisions 100 MHz (FLUKE 196B/C 1 division 150 MHz (FLUKE 196B/C 2 divisions 60 MHz (FLUKE 192B 1 division 100 MHz (FLUKE 192B 2 divisions Isolated ...External Trigger Bandwidth 10 kHz Modes Automatic, Edge Trigger Levels (DC to 120 s/div......... displays glitches as fast as 50 ns Waveform Display A, B, A+B, A-B, A*B, A vs B Normal, Average (2,4,8,64 x), Persistence Time Base Accuracy 100 ppm + 0.04 div) Trigger and Delay Trigger Modes Automatic, Edge, External, Video...
FE 192,196,199 C Users Manual
Page 122
..., 58 N-Cycle, 57 On Edges, 55 On Pulses, 61 On Video, 59 On Waveforms, 51 Troubleshooting, 93 TV Triggering, 59 -U- Vertical Accuracy, 96 Vertical Cursors, 47 Vibration, 107 Video Frames, 60 Video Lines, 60 Video Trigger, 59, 97 Viewing Stored Screens, 69 Voltage Probes, 3, 86..., 89 VP200 Voltage Probe, 89 VP200 Voltage Probe Set, 3 -W- Zoom, 44, 105 Waveform comparing, 23 Waveform Options, 15 Waveform storage, 66 -X- Unpacking, 2 Users Manual, 3, 91 114 -V- Fluke 192B -...
..., 58 N-Cycle, 57 On Edges, 55 On Pulses, 61 On Video, 59 On Waveforms, 51 Troubleshooting, 93 TV Triggering, 59 -U- Vertical Accuracy, 96 Vertical Cursors, 47 Vibration, 107 Video Frames, 60 Video Lines, 60 Video Trigger, 59, 97 Viewing Stored Screens, 69 Voltage Probes, 3, 86..., 89 VP200 Voltage Probe, 89 VP200 Voltage Probe Set, 3 -W- Zoom, 44, 105 Waveform comparing, 23 Waveform Options, 15 Waveform storage, 66 -X- Unpacking, 2 Users Manual, 3, 91 114 -V- Fluke 192B -...
Fluke ScopeMeter Product Datasheet
Page 2
... complex dynamic signals by on a digital datastream. This enables you the required resolution for example, the color burst in a video signal or a single impulse in your preferred time window. Advanced trigger modes The ScopeMeter 190 Series simplifies triggering with 400 ps...color labels, measurements and warnings are clearly linked to specific waveforms. See dynamic signal behavior instantaneously The Digital Persistence mode (Fluke 190C) helps to identify the individual frequency components contained in conjunction with the highest resolution and detail. An automatic window ...
... complex dynamic signals by on a digital datastream. This enables you the required resolution for example, the color burst in a video signal or a single impulse in your preferred time window. Advanced trigger modes The ScopeMeter 190 Series simplifies triggering with 400 ps...color labels, measurements and warnings are clearly linked to specific waveforms. See dynamic signal behavior instantaneously The Digital Persistence mode (Fluke 190C) helps to identify the individual frequency components contained in conjunction with the highest resolution and detail. An automatic window ...
Fluke ScopeMeter Product Datasheet
Page 5
...Waveform compare FFT Pass/Fail testing Triggering Connect-and-View™ Triggering Edge, single, free run Video Video line select Pulse width External Advanced Functions Cursors Zoom Dual Input TrendPlot™ ScopeRecord™ Mode ...; Test Tools Bandwidth Max. harmonics - to change without notice. Ordering information Fluke 199C Fluke 199C/S Fluke 196C Fluke 196C/S Fluke 199B Fluke 199B/S Fluke 196B Fluke 196B/S Fluke 192B Fluke 192B/S Fluke 125 Fluke 125/S Fluke 124 Fluke 124/S Fluke 123 Fluke 123/S SCC190 SCC120 OC4USB PM9080 SW90W Color ScopeMeter (200 MHz / 2.5 GS...
...Waveform compare FFT Pass/Fail testing Triggering Connect-and-View™ Triggering Edge, single, free run Video Video line select Pulse width External Advanced Functions Cursors Zoom Dual Input TrendPlot™ ScopeRecord™ Mode ...; Test Tools Bandwidth Max. harmonics - to change without notice. Ordering information Fluke 199C Fluke 199C/S Fluke 196C Fluke 196C/S Fluke 199B Fluke 199B/S Fluke 196B Fluke 196B/S Fluke 192B Fluke 192B/S Fluke 125 Fluke 125/S Fluke 124 Fluke 124/S Fluke 123 Fluke 123/S SCC190 SCC120 OC4USB PM9080 SW90W Color ScopeMeter (200 MHz / 2.5 GS...