Fluke 902 HVAC Clamp Meter Datasheet
Page 2
...;F to dual banana plug inputs • Measurement range and accu- Ordering Information Fluke-902 HVAC Clamp Meter Included AA alkaline batteries (2) Users manual (w/safety information) Soft carrying case TL75 Test Leads (1 pair) 80BK Integrated DMM Temperature Probe (1) Optional accessories H3 Clamp Meter Holster • Rugged fabric holster includes flap for lead storage and built-in...
...;F to dual banana plug inputs • Measurement range and accu- Ordering Information Fluke-902 HVAC Clamp Meter Included AA alkaline batteries (2) Users manual (w/safety information) Soft carrying case TL75 Test Leads (1 pair) 80BK Integrated DMM Temperature Probe (1) Optional accessories H3 Clamp Meter Holster • Rugged fabric holster includes flap for lead storage and built-in...
FE 902 Users Manual
Page 7
902 Introduction The Fluke 902 is a hand-held battery-operated HVAC Clamp Meter ("the Meter") that measures: • AC current • DC current (up to 200 µA for flame rod testing) • AC and DC voltages • Capacitance • Resistance • Continuity • Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case • TL75 Test Leads (one pair) • 80BK Integrated DMM Temperature Probe 1
902 Introduction The Fluke 902 is a hand-held battery-operated HVAC Clamp Meter ("the Meter") that measures: • AC current • DC current (up to 200 µA for flame rod testing) • AC and DC voltages • Capacitance • Resistance • Continuity • Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case • TL75 Test Leads (one pair) • 80BK Integrated DMM Temperature Probe 1
FE 902 Users Manual
Page 10
Such voltages pose a shock hazard. • Clean the case with voltages above 60 V dc or 30 V ac rms or 42 V ac peak. Do not use abrasives or solvents. • To avoid false readings that ... measurements can lead to prevent shock and arc blast injury where hazardous live conductors are changed. • Do not hold the Meter anywhere beyond the tactile barrier, see Figure 1. • Adhere to local and national safety codes. 902 Users Manual • Use caution when working with a damp cloth and mild detergent only.
Such voltages pose a shock hazard. • Clean the case with voltages above 60 V dc or 30 V ac rms or 42 V ac peak. Do not use abrasives or solvents. • To avoid false readings that ... measurements can lead to prevent shock and arc blast injury where hazardous live conductors are changed. • Do not hold the Meter anywhere beyond the tactile barrier, see Figure 1. • Adhere to local and national safety codes. 902 Users Manual • Use caution when working with a damp cloth and mild detergent only.
FE 902 Users Manual
Page 26
902 Users Manual Maintenance XWWarning To avoid possible electric shock or personal injury, repairs or servicing not covered in the Meter. Cleaning the Meter XWWarning To avoid electrical shock, remove any input signals before cleaning. These solutions will react with a damp cloth and mild detergent. 20 Clean the instrument case with the plastics used in this manual should be performed only by qualified personnel. W Caution To avoid damaging the Meter, do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
902 Users Manual Maintenance XWWarning To avoid possible electric shock or personal injury, repairs or servicing not covered in the Meter. Cleaning the Meter XWWarning To avoid electrical shock, remove any input signals before cleaning. These solutions will react with a damp cloth and mild detergent. 20 Clean the instrument case with the plastics used in this manual should be performed only by qualified personnel. W Caution To avoid damaging the Meter, do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
FE 902 Users Manual
Page 27
... the batteries as soon as the low battery indicator (B) appears. Turn the rotary switch to Figure 6): 1. HVAC Clamp Meter Maintenance Battery Replacement XWWarning To avoid false readings that could lead to the case bottom and tighten the screw. 21 Remove the batteries. 4. To replace the batteries (refer to "OFF" and remove the...
... the batteries as soon as the low battery indicator (B) appears. Turn the rotary switch to Figure 6): 1. HVAC Clamp Meter Maintenance Battery Replacement XWWarning To avoid false readings that could lead to the case bottom and tighten the screw. 21 Remove the batteries. 4. To replace the batteries (refer to "OFF" and remove the...