...-PhotoNotes photo annotation system, WiFi connectivity, Bluetooth connectivity, and HDMI video connectivity. 1 Introduction The Fluke Ti200, Ti300, Ti400, and Ti450 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use on a high-visibility, industrial-quality 640 x 480 LCD touch screen and can be transferred to a PC through...
...-PhotoNotes photo annotation system, WiFi connectivity, Bluetooth connectivity, and HDMI video connectivity. 1 Introduction The Fluke Ti200, Ti300, Ti400, and Ti450 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use on a high-visibility, industrial-quality 640 x 480 LCD touch screen and can be transferred to a PC through...
User Manual
Page 21
... Auto Focus System and laser pointer. Features and Controls (cont.) Description USB Cable Connection LED Torch/Flashlight Retractable Lens Cover Visual Light Camera Lens Laser Pointer/Range Finder Infrared Camera Lens Secondary Trigger Primary Trigger Primary and Secondary Triggers The two-part trigger is to capture a thermal image for information about how to...
... Auto Focus System and laser pointer. Features and Controls (cont.) Description USB Cable Connection LED Torch/Flashlight Retractable Lens Cover Visual Light Camera Lens Laser Pointer/Range Finder Infrared Camera Lens Secondary Trigger Primary Trigger Primary and Secondary Triggers The two-part trigger is to capture a thermal image for information about how to...
User Manual
Page 29
.... Many common objects and materials such as they have an emissivity of The Imager senses the infrared energy from the surface of the object. The quantity of energy radiated is based on shiny surfaces or unpainted metals as painted metal, wood, water, ...
.... Many common objects and materials such as they have an emissivity of The Imager senses the infrared energy from the surface of the object. The quantity of energy radiated is based on shiny surfaces or unpainted metals as painted metal, wood, water, ...
User Manual
Page 53
... your password. 5. Push . Thermal Imagers Menus Memory Menu The Memory Menu allows you to indicate any additional information that has been saved with the infrared image or IR-Fusion technology image: k IR-PhotoNotes photos Voice annotation Video Text annotation Review Image Files To view stored images in... highlight the thumbnail of the file to highlight the thumbnail of the file for review. 3. Push . 4. Push . Go to Memory. 2. Push to Camera > Wireless > Sign Out. 2. To sign out: 1. Go to review the file.
... your password. 5. Push . Thermal Imagers Menus Memory Menu The Memory Menu allows you to indicate any additional information that has been saved with the infrared image or IR-Fusion technology image: k IR-PhotoNotes photos Voice annotation Video Text annotation Review Image Files To view stored images in... highlight the thumbnail of the file to highlight the thumbnail of the file for review. 3. Push . 4. Push . Go to Memory. 2. Push to Camera > Wireless > Sign Out. 2. To sign out: 1. Go to review the file.
User Manual
Page 54
... Ti400,Ti450 Users Manual 3. Push again to Memory. 2. Go to delete the file. Push to use the Fluke Connect App with Apple and Android products. The Fluke Connect system is available for you to Fluke Connect Mobile App > On. 3. How to delete all countries. Turn on your infrared camera on ...the Imager. 2. The app is not available in all files in all the images from your smartphone or tablet screen for download from the Apple App Store and Google Play. On your mobile device, go to Fluke Connect > Pair to...
... Ti400,Ti450 Users Manual 3. Push again to Memory. 2. Go to delete the file. Push to use the Fluke Connect App with Apple and Android products. The Fluke Connect system is available for you to Fluke Connect Mobile App > On. 3. How to delete all countries. Turn on your infrared camera on ...the Imager. 2. The app is not available in all files in all the images from your smartphone or tablet screen for download from the Apple App Store and Google Play. On your mobile device, go to Fluke Connect > Pair to...
User Manual
Page 67
... Detailed Specifications Detailed Specifications Temperature Measurements Temperature Range (not calibrated below -10 °C) Ti200, Ti300 20 °C to +650 °C Ti400, Ti450 20 °C to +1200 °C Accuracy 2 °C or 2 % (whichever is greater) at 25 °C ambient On-screen emissivity ...075 °C at 30 °C target temp (75 mK) Total pixels Ti400, Ti450 76 800 Ti300 43 200 Ti200 30 000 Infrared spectral band 7.5 μm to 14 μm (long wave) Visual (Visible Light) Camera Type Industrial performance 5.0 MP Parallax alignment with standard IR lens From ~60 cm (~...
... Detailed Specifications Detailed Specifications Temperature Measurements Temperature Range (not calibrated below -10 °C) Ti200, Ti300 20 °C to +650 °C Ti400, Ti450 20 °C to +1200 °C Accuracy 2 °C or 2 % (whichever is greater) at 25 °C ambient On-screen emissivity ...075 °C at 30 °C target temp (75 mK) Total pixels Ti400, Ti450 76 800 Ti300 43 200 Ti200 30 000 Infrared spectral band 7.5 μm to 14 μm (long wave) Visual (Visible Light) Camera Type Industrial performance 5.0 MP Parallax alignment with standard IR lens From ~60 cm (~...