Complete Owner's Guide (English)
Page 8
... OPERATING INSTRUCTIONS allergy normal mixed load casual towels quick dry bulky delicates heavy time dry ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start chime shrink guard control lock allergy normal towels heavy/ bulky casual quick dry...casual normal towels heavy/ bulky quick dry delicates steam refresh time dry specialty cycles ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start shrink guard anti static control lock ...
... OPERATING INSTRUCTIONS allergy normal mixed load casual towels quick dry bulky delicates heavy time dry ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start chime shrink guard control lock allergy normal towels heavy/ bulky casual quick dry...casual normal towels heavy/ bulky quick dry delicates steam refresh time dry specialty cycles ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start shrink guard anti static control lock ...
Complete Owner's Guide (English)
Page 9
...load casual normal towels heavy/ bulky quick dry delicates steam refresh time dry specialty cycles ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start chime shrink guard control lock Continue turning... and bath mats. allergy normal mixed load casual towels quick dry bulky delicates heavy time dry ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start shrink guard anti static control lock "Dry Time" button On models without a Dry...
...load casual normal towels heavy/ bulky quick dry delicates steam refresh time dry specialty cycles ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start chime shrink guard control lock Continue turning... and bath mats. allergy normal mixed load casual towels quick dry bulky delicates heavy time dry ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start shrink guard anti static control lock "Dry Time" button On models without a Dry...
Complete Owner's Guide (English)
Page 10
...Selection allergy normal towels heavy/ bulky casual quick dry delicates steam refresh time dry specialty cycles ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line dry delay start shrink guard anti static control lock Specialty Cycles (...mixed load casual normal towels heavy/ bulky quick dry delicates steam refresh time dry specialty cycles ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up an entire dry load left in a pillow case and tying the end closed before ...
...Selection allergy normal towels heavy/ bulky casual quick dry delicates steam refresh time dry specialty cycles ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line dry delay start shrink guard anti static control lock Specialty Cycles (...mixed load casual normal towels heavy/ bulky quick dry delicates steam refresh time dry specialty cycles ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up an entire dry load left in a pillow case and tying the end closed before ...
Complete Owner's Guide (English)
Page 11
... of bacteria between loads. Select the Normal dry level for each cycle. For loads requiring less drying time, select Less. Sanitize Recommended for delicate fabrics. Low Recommended for durable fabrics and towels. and to the desired setting. The Dry Level selected for the cycle will be used with every cycle. To...
... of bacteria between loads. Select the Normal dry level for each cycle. For loads requiring less drying time, select Less. Sanitize Recommended for delicate fabrics. Low Recommended for durable fabrics and towels. and to the desired setting. The Dry Level selected for the cycle will be used with every cycle. To...
Complete Owner's Guide (English)
Page 12
... to activate or deactivate the secondary function. Closing the door turns off , press and hold the button again. 12 ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start chime shrink guard control lock ready steam system sanitize high normal...75 60 30 touch up wrinkle release line dry delay start add steam anti static control lock ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start shrink guard anti static control lock Some Options...
... to activate or deactivate the secondary function. Closing the door turns off , press and hold the button again. 12 ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start chime shrink guard control lock ready steam system sanitize high normal...75 60 30 touch up wrinkle release line dry delay start add steam anti static control lock ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start shrink guard anti static control lock Some Options...
Complete Owner's Guide (English)
Page 13
... steam into the clothing just before cycle completion to redistribute the load, maximizing load freshness. OPERATING INSTRUCTIONS ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start chime shrink guard control lock ready steam system sanitize high normal... 30 touch up wrinkle release line dry delay start add steam anti static control lock ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start shrink guard anti static control lock 13 ...
... steam into the clothing just before cycle completion to redistribute the load, maximizing load freshness. OPERATING INSTRUCTIONS ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start chime shrink guard control lock ready steam system sanitize high normal... 30 touch up wrinkle release line dry delay start add steam anti static control lock ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start shrink guard anti static control lock 13 ...
Complete Owner's Guide (English)
Page 15
...time dry These Temperatures, Dryness levels and Options are available with the following cycles: ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start chime shrink guard control lock Heavy Bulky Towels Normal Allergy Mixed Load ... select models) Casual Quick Dry Delicates Time Dry (15-75 min) Time Dry (90 min) Temp Sanitize High Normal Low Air Dry 9 9 9 9 9999999 9 99 999 999 9 999 99 Dry Level Max High Normal Low Damp 9 9 9 99999999 9 99 9 999 9 9 999 9 9 9 Options Energy Saver 9 999 Wrinkle Release ...
...time dry These Temperatures, Dryness levels and Options are available with the following cycles: ultra capacity sanitize high normal low air dry max high normal low damp wrinkle release line dry delay start chime shrink guard control lock Heavy Bulky Towels Normal Allergy Mixed Load ... select models) Casual Quick Dry Delicates Time Dry (15-75 min) Time Dry (90 min) Temp Sanitize High Normal Low Air Dry 9 9 9 9 9999999 9 99 999 999 9 999 99 Dry Level Max High Normal Low Damp 9 9 9 99999999 9 99 9 999 9 9 999 9 9 9 Options Energy Saver 9 999 Wrinkle Release ...
Complete Owner's Guide (English)
Page 16
...These Temperatures, Dryness levels and Options are available with the following cycles: ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line dry delay start add steam anti static control ...) Time Dry (90) Warm Up (on select models) Jeans Kids Wear Stuffed Toys Active Wear Temp Sanitize High Normal Low Air Dry 99 9 9 9 9999 9 99999 9 9 99 9 9 9 99 9 99 Dry Level Max High Normal Low Damp 99 9 99999 9 9 9 9 9 9 9 9 9 9 99 9 9 Options Energy Saver 9 9 9 Add Steam 9 9 99 9 Wrinkle ...
...These Temperatures, Dryness levels and Options are available with the following cycles: ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line dry delay start add steam anti static control ...) Time Dry (90) Warm Up (on select models) Jeans Kids Wear Stuffed Toys Active Wear Temp Sanitize High Normal Low Air Dry 99 9 9 9 9999 9 99999 9 9 99 9 9 9 99 9 99 Dry Level Max High Normal Low Damp 99 9 99999 9 9 9 9 9 9 9 9 9 9 99 9 9 Options Energy Saver 9 9 9 Add Steam 9 9 99 9 Wrinkle ...
Complete Owner's Guide (English)
Page 17
... cycles These Temperatures, Dryness levels and Options are available with the following cycles: ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start shrink guard anti static control lock ... - 75) Time Dry (90) Jeans Pet Bed Kids Wear Stuffed Toys Active Wear Warm-Up Temp Sanitize High Normal Low Air Dry 99 9 9 999 9 99999 9 99 9 99 9 9 9 99 9 99 Dryness Max High Normal Low Damp 99 99999 9 9 999 9 999 9 99 9 9 99 9 9 Options Allergy 9999 9 Energy Saver 999 9 ...
... cycles These Temperatures, Dryness levels and Options are available with the following cycles: ready steam system sanitize high normal low air dry max high normal low damp 90 75 60 30 touch up wrinkle release line chime dry delay start shrink guard anti static control lock ... - 75) Time Dry (90) Jeans Pet Bed Kids Wear Stuffed Toys Active Wear Warm-Up Temp Sanitize High Normal Low Air Dry 99 9 9 999 9 99999 9 99 9 99 9 9 9 99 9 99 Dryness Max High Normal Low Damp 99 99999 9 9 999 9 999 9 99 9 9 99 9 9 Options Allergy 9999 9 Energy Saver 999 9 ...
Complete Owner's Guide (English)
Page 19
... care label directions. • If shrinking is a concern, check load often. • Remove items while slightly damp and hang or lay flat medium or low heat for proper tumbling. • Some "silk-like" fabrics should be air dried. • Use proper drying temperature. • Place fabric softener sheet on top...
... care label directions. • If shrinking is a concern, check load often. • Remove items while slightly damp and hang or lay flat medium or low heat for proper tumbling. • Some "silk-like" fabrics should be air dried. • Use proper drying temperature. • Place fabric softener sheet on top...
Wiring Diagram (All Languages)
Page 1
...evidence of high temperature event and any resulting count too high Limiter tripped (Electric Model only) damage. E52 Motor Fault - Low power supply; Check heater coils and connections for continuity. For Gas Model, also check Inlet Thermal Limiter for short circuits ... Electronic Control Board defective or foreign object interfering with contact sensor E32 Contact Sensor Electronic Control Board defective or frequency too low foreign object interfering with Contact Sensor, replace Electronic Control Board. If no wiring problems are found , replace Electronic Control ...
...evidence of high temperature event and any resulting count too high Limiter tripped (Electric Model only) damage. E52 Motor Fault - Low power supply; Check heater coils and connections for continuity. For Gas Model, also check Inlet Thermal Limiter for short circuits ... Electronic Control Board defective or foreign object interfering with contact sensor E32 Contact Sensor Electronic Control Board defective or frequency too low foreign object interfering with Contact Sensor, replace Electronic Control Board. If no wiring problems are found , replace Electronic Control ...
Wiring Diagram (All Languages)
Page 2
... Check amplitude of limits or Electronic Control Board faulty Line voltage too high or Electronic Control Board faulty Line voltage too low or Electronic Control Board faulty Line connections in home faulty, wiring or Electronic Control Board defective Replace Electronic Control Board. .... Replace appropriate hardware. E97 Program mismatch Main Supply EA1 Frequency out of Range Voltage too high EA2 EA3 Voltage too low Improper home EA4 wiring Wrong configuration data loaded, Electronic Control Board defective Line frequency out of line voltage. Upon entering Diagnostic...
... Check amplitude of limits or Electronic Control Board faulty Line voltage too high or Electronic Control Board faulty Line voltage too low or Electronic Control Board faulty Line connections in home faulty, wiring or Electronic Control Board defective Replace Electronic Control Board. .... Replace appropriate hardware. E97 Program mismatch Main Supply EA1 Frequency out of Range Voltage too high EA2 EA3 Voltage too low Improper home EA4 wiring Wrong configuration data loaded, Electronic Control Board defective Line frequency out of line voltage. Upon entering Diagnostic...