Page 4
...:2001] SCSI Primary Commands-2 (SPC-2) T10/996D Rev. 8c [NCITS.306:1998] SCSI-3 Block Commands (SBC) T10/1157D Rev. 24 SCSI Architecture Model-2 (SAM-2) T10/1561D Rev. 14 SCSI Architecture Model-3 (SAM-3) T10/1562D Rev. 05 Serial Attached SCSI (SAS) T10/1601D Rev. 10 Serial Attached SCSI... Model-1.1 (SAS 1.1) *1 ANSI = American National Standard Institute In case of conflict between this manual and any packaging part of China This product is ...
...:2001] SCSI Primary Commands-2 (SPC-2) T10/996D Rev. 8c [NCITS.306:1998] SCSI-3 Block Commands (SBC) T10/1157D Rev. 24 SCSI Architecture Model-2 (SAM-2) T10/1561D Rev. 14 SCSI Architecture Model-3 (SAM-3) T10/1562D Rev. 05 Serial Attached SCSI (SAS) T10/1601D Rev. 10 Serial Attached SCSI... Model-1.1 (SAS 1.1) *1 ANSI = American National Standard Institute In case of conflict between this manual and any packaging part of China This product is ...
Product Manual
Page 16
Contents Tables Table 2.1 Model names and order numbers 19 Table 2.2 Function specifications 20 Table 2.3 Environmental/Power requirements 23 Table 3.1 Format capacity 34 Table 4.1 Surface temperature check point and maximum temperature ....... 46 Table 4.2 Interface connector (SAS plug) signal allocation:CN1 52 Table 4.3 Recommended connectors 53 Table 6.1 Self-diagnostic functions 65 Table 6.2 System-level field troubleshooting 75 Table 6.3 HDD troubleshooting 76 Table 7.1 Definition of sense data 83 12 C141-E252
Contents Tables Table 2.1 Model names and order numbers 19 Table 2.2 Function specifications 20 Table 2.3 Environmental/Power requirements 23 Table 3.1 Format capacity 34 Table 4.1 Surface temperature check point and maximum temperature ....... 46 Table 4.2 Interface connector (SAS plug) signal allocation:CN1 52 Table 4.3 Recommended connectors 53 Table 6.1 Self-diagnostic functions 65 Table 6.2 System-level field troubleshooting 75 Table 6.3 HDD troubleshooting 76 Table 7.1 Definition of sense data 83 12 C141-E252
Product Manual
Page 23
... less and actual capacity depends on the operating environment and formatting. Table 2.1 Model names and order numbers Model name Order number Interface type Capacity (user area) MBA3300RC CA06778-B400 SAS 300 GB (*) MBA3147RC CA06778-B200 SAS 147 GB (*) MBA3073RC CA06778-B100 SAS 73.5 GB (*) (*) One gigabyte (GB) = one billion bytes; CHAPTER 2 Specifications 2.1 Hardware Specifications This chapter describes specifications...
... less and actual capacity depends on the operating environment and formatting. Table 2.1 Model names and order numbers Model name Order number Interface type Capacity (user area) MBA3300RC CA06778-B400 SAS 300 GB (*) MBA3147RC CA06778-B200 SAS 147 GB (*) MBA3073RC CA06778-B100 SAS 73.5 GB (*) (*) One gigabyte (GB) = one billion bytes; CHAPTER 2 Specifications 2.1 Hardware Specifications This chapter describes specifications...
Product Manual
Page 38
... be accessed using the logical data block address of the spare sector area. Table 3.1 lists examples of alternate spare sectors per cell - Table 3.1 Format capacity Model MBA3300RC MBA3147RC MBA3073RC Data block length 512 User blocks 585, 937, 500 287, 277, 984 143, 638, 992 Format capacity...
... be accessed using the logical data block address of the spare sector area. Table 3.1 lists examples of alternate spare sectors per cell - Table 3.1 Format capacity Model MBA3300RC MBA3147RC MBA3073RC Data block length 512 User blocks 585, 937, 500 287, 277, 984 143, 638, 992 Format capacity...
Product Manual
Page 63
... INTERFACE MANUAL for Use c) Issue the REQUEST SENSE command to the procedures below. Block descriptor Specify the size (byte length) of spare sectors for each model (part number) when shipped from the factory, the disk need not be formatted (initialized) when it is installed in the user space This section outlines...
... INTERFACE MANUAL for Use c) Issue the REQUEST SENSE command to the procedures below. Block descriptor Specify the size (byte length) of spare sectors for each model (part number) when shipped from the factory, the disk need not be formatted (initialized) when it is installed in the user space This section outlines...
Product Manual
Page 74
... 2.1.5. (3) Parts that can be replaced in the field The PCBA cannot be replaced in the field. (4) Service system and repairs Fujitsu has the service system and repair facility for replacing or repairing the HDD. Generally, the following information must be replaced in the field.... The DE cannot be included: a) Model part number (P/N), revision number, serial number (S/N), and date of manufacturing b) Error status • Date when the error occurred • System...
... 2.1.5. (3) Parts that can be replaced in the field The PCBA cannot be replaced in the field. (4) Service system and repairs Fujitsu has the service system and repair facility for replacing or repairing the HDD. Generally, the following information must be replaced in the field.... The DE cannot be included: a) Model part number (P/N), revision number, serial number (S/N), and date of manufacturing b) Error status • Date when the error occurred • System...
Product Manual
Page 94
...-mounting 45 logical data block addressing 34 M maintenance 69 maintenance level 71 maintenance requirement 70 microcode downloading 16 MODE SELECT/MODE SELECT EXTENDED command 59 model name 19 mounting frame structure 44 mounting HDDs 57 mounting orientations 43 mounting procedure 57 mounting requirement 41 mounting screw 44 MTBF 24 MTTR 25...
...-mounting 45 logical data block addressing 34 M maintenance 69 maintenance level 71 maintenance requirement 70 microcode downloading 16 MODE SELECT/MODE SELECT EXTENDED command 59 model name 19 mounting frame structure 44 mounting HDDs 57 mounting orientations 43 mounting procedure 57 mounting requirement 41 mounting screw 44 MTBF 24 MTTR 25...