Owners Manual
Page 1
....com Safety Instructions 2-5 Operating Instructions Controls 6-8 Cycle Options 9-10 Dryer Features 11 Loading and Using the Dryer 12, 13 Installation Instructions Before You Begin 14-16 Connecting a Gas Dryer 17-20 Connecting an Electric Dryer 21-23 Exhausting the Dryer 24-28 Final Setup 29, 30 Reversing the Door Swing . . . . . .31, 32 Troubleshooting Tips 33 Consumer... Instructions DPGT650 UPGT650 Printed in Korea Write the model and serial numbers here: Model Serial They are on the label on the front of the dryer behind the door. 175D1807P640 49-90378 04-09 JR
....com Safety Instructions 2-5 Operating Instructions Controls 6-8 Cycle Options 9-10 Dryer Features 11 Loading and Using the Dryer 12, 13 Installation Instructions Before You Begin 14-16 Connecting a Gas Dryer 17-20 Connecting an Electric Dryer 21-23 Exhausting the Dryer 24-28 Final Setup 29, 30 Reversing the Door Swing . . . . . .31, 32 Troubleshooting Tips 33 Consumer... Instructions DPGT650 UPGT650 Printed in Korea Write the model and serial numbers here: Model Serial They are on the label on the front of the dryer behind the door. 175D1807P640 49-90378 04-09 JR
Owners Manual
Page 2
... Tips 2 Operating Instructions Safety Instructions IMPORTANT SAFETY INFORMATION. Follow the gas supplier's instructions carefully. 5 If you cannot reach your gas supplier, call your gas supplier from a neighbor's phone. Gas appliances can be minimized further by properly venting the dryer to the outdoors. Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances, namely benzene, carbon...
... Tips 2 Operating Instructions Safety Instructions IMPORTANT SAFETY INFORMATION. Follow the gas supplier's instructions carefully. 5 If you cannot reach your gas supplier, call your gas supplier from a neighbor's phone. Gas appliances can be minimized further by properly venting the dryer to the outdoors. Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances, namely benzene, carbon...
Owners Manual
Page 5
...automatic ignition turns on , tripped over or subjected to damage. ■ Before discarding a dryer, or removing it from service, remove the dryer door to prevent children from traffic areas so it is a gas dryer, it will not be safely used in your laundered fabrics or reduce the static electricity in... them by using a dryer-applied fabric softener or an anti-static conditioner. READ AND ...
...automatic ignition turns on , tripped over or subjected to damage. ■ Before discarding a dryer, or removing it from service, remove the dryer door to prevent children from traffic areas so it is a gas dryer, it will not be safely used in your laundered fabrics or reduce the static electricity in... them by using a dryer-applied fabric softener or an anti-static conditioner. READ AND ...
Owners Manual
Page 14
...8226; Note to four of these instructions with flexible plastic ducting materials. Gas appliances can be easily crushed and trap lint. Installation Instructions Dryer DPGT650 and UPGT650 Questions? Close supervision of the dryer control system. • Remove and discard existing plastic or metal foil...176;F for future reference. • Clothes dryer installation must be performed by a qualified installer. • Install the clothes dryer according to these instructions for exhausting the clothes dryer to House Vent" on or in garages. Call 800.GE.CARES (800.432.2737) or visit our...
...8226; Note to four of these instructions with flexible plastic ducting materials. Gas appliances can be easily crushed and trap lint. Installation Instructions Dryer DPGT650 and UPGT650 Questions? Close supervision of the dryer control system. • Remove and discard existing plastic or metal foil...176;F for future reference. • Clothes dryer installation must be performed by a qualified installer. • Install the clothes dryer according to these instructions for exhausting the clothes dryer to House Vent" on or in garages. Call 800.GE.CARES (800.432.2737) or visit our...
Owners Manual
Page 15
...THAN ALCOVE OR CLOSET INSTALLATION Minimum clearance to combustible surfaces and for air openings are not approved for proper operation and service. LOCATION OF YOUR DRYER IMPORTANT: Gas dryers are : • 0 inch clearance both sides • 1 inch front • 3 inches rear Consideration must be given to remove... and remove the foam shipping pads by pulling at the sides and breaking them away from the dryer legs. DRYER DIMENSIONS Front View 437⁄ 8″ (111.4 cm) Side View 27″ (68.6 cm) 351⁄ 2″ (90.2 cm) 371⁄ 4″ (94.6 cm) 51″ (129.5 cm)...
...THAN ALCOVE OR CLOSET INSTALLATION Minimum clearance to combustible surfaces and for air openings are not approved for proper operation and service. LOCATION OF YOUR DRYER IMPORTANT: Gas dryers are : • 0 inch clearance both sides • 1 inch front • 3 inches rear Consideration must be given to remove... and remove the foam shipping pads by pulling at the sides and breaking them away from the dryer legs. DRYER DIMENSIONS Front View 437⁄ 8″ (111.4 cm) Side View 27″ (68.6 cm) 351⁄ 2″ (90.2 cm) 371⁄ 4″ (94.6 cm) 51″ (129.5 cm)...
Owners Manual
Page 16
... installed in the same closet with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric dryers) or NATIONAL FUEL GAS CODE, ANSI Z223 (for gas dryers). 16 See the EXHAUST INFORMATION section. • Minimum clearance between dryer cabinet and adjacent walls or other fuel-burning appliance shall be vented to overhead shelves, cabinets, ceilings...
... installed in the same closet with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric dryers) or NATIONAL FUEL GAS CODE, ANSI Z223 (for gas dryers). 16 See the EXHAUST INFORMATION section. • Minimum clearance between dryer cabinet and adjacent walls or other fuel-burning appliance shall be vented to overhead shelves, cabinets, ceilings...
Owners Manual
Page 17
...-end wrenches for flexible tube and connector ❒ Adjustable pliers (to the OFF position. Shutoff Valve Disconnect and discard old flexible gas connector and ducting material. 17 Installation Instructions CONNECTING A GAS DRYER (skip for tightening connections Turn the dryer's gas shutoff valve in the supply line to adjust leveling legs) ❒ Pipe wrench for holding...
...-end wrenches for flexible tube and connector ❒ Adjustable pliers (to the OFF position. Shutoff Valve Disconnect and discard old flexible gas connector and ducting material. 17 Installation Instructions CONNECTING A GAS DRYER (skip for tightening connections Turn the dryer's gas shutoff valve in the supply line to adjust leveling legs) ❒ Pipe wrench for holding...
Owners Manual
Page 18
...is equipped with a Valve and Burner Assembly for use with propane (LP) gas. DRYER GAS SUPPLY CONNECTION 31⁄ 4″ (8.2 cm) 23⁄ 8″ (6 cm) 3/8″ NPT MALE THREAD GAS SUPPLY NOTE: Add to vertical dimension the distance between cabinet bottom to be ...tape. • Connect flexible metal connector to dryer and gas supply. ADJUSTING FOR ELEVATION • Gas clothes dryers input ratings are based on the installation of 4 percent for each 1000 ft. Installation Instructions CONNECTING A GAS DRYER (cont.) GAS REQUIREMENTS WARNING • Installation must conform to ...
...is equipped with a Valve and Burner Assembly for use with propane (LP) gas. DRYER GAS SUPPLY CONNECTION 31⁄ 4″ (8.2 cm) 23⁄ 8″ (6 cm) 3/8″ NPT MALE THREAD GAS SUPPLY NOTE: Add to vertical dimension the distance between cabinet bottom to be ...tape. • Connect flexible metal connector to dryer and gas supply. ADJUSTING FOR ELEVATION • Gas clothes dryers input ratings are based on the installation of 4 percent for each 1000 ft. Installation Instructions CONNECTING A GAS DRYER (cont.) GAS REQUIREMENTS WARNING • Installation must conform to ...
Owners Manual
Page 19
...two adjustable wrenches. NOTE: Apply pipe compound or Teflon® tape to the end of the dryer gas inlet. Shut-off valve for checking gas inlet pressure. C Tighten the flexible gas line connection using two adjustable wrenches. Apply pipe compound or Teflon® tape to the adapter.... NOTE: Apply pipe compound or Teflon® tape to the dryer gas line shut-off Valve E Tighten all male threads. Install a 3/8″ flare union adapter to the plugged tapping. Do not overtighten. ...
...two adjustable wrenches. NOTE: Apply pipe compound or Teflon® tape to the end of the dryer gas inlet. Shut-off valve for checking gas inlet pressure. C Tighten the flexible gas line connection using two adjustable wrenches. Apply pipe compound or Teflon® tape to the adapter.... NOTE: Apply pipe compound or Teflon® tape to the dryer gas line shut-off Valve E Tighten all male threads. Install a 3/8″ flare union adapter to the plugged tapping. Do not overtighten. ...
Owners Manual
Page 20
...in accordance with local codes and ordinances or, in the absence of local codes, in accordance with this plug. ELECTRICAL REQUIREMENTS FOR GAS DRYERS This appliance must not contain ammonia, which meets local codes, may be plugged directly into a properly grounded three-prong receptacle. ...or 20-amp circuit breaker or time-delay fuse. Apply a soap solution. Open Gas Valve ELECTRICAL CONNECTION INFORMATION FOR GAS DRYERS WARNING - Ensure proper ground exists before use an open flame to the green ground screw on the rear of fire...
...in accordance with local codes and ordinances or, in the absence of local codes, in accordance with this plug. ELECTRICAL REQUIREMENTS FOR GAS DRYERS This appliance must not contain ammonia, which meets local codes, may be plugged directly into a properly grounded three-prong receptacle. ...or 20-amp circuit breaker or time-delay fuse. Apply a soap solution. Open Gas Valve ELECTRICAL CONNECTION INFORMATION FOR GAS DRYERS WARNING - Ensure proper ground exists before use an open flame to the green ground screw on the rear of fire...
Owners Manual
Page 21
...#2 Phillips-head screwdriver (for terminal connections) FOR YOUR SAFETY: WARNING Before making the electrical connection, turn off the circuit breaker(s) or remove the dryer's circuit fuse(s) at the electrical box. Closed-loop or forked terminals with cord) ❒ UL-listed power cord - 30-amp - 240V -...• Do not use an extension cord or an adapter plug with this appliance. • The dryer must be supplied with upturned ends - 3-wire (for construction before 1996) or 4-wire (for gas dryers) TOOLS AND MATERIALS YOU WILL NEED FOR CONNECTING THE ELECTRICAL SUPPLY ❒ Flat-
...#2 Phillips-head screwdriver (for terminal connections) FOR YOUR SAFETY: WARNING Before making the electrical connection, turn off the circuit breaker(s) or remove the dryer's circuit fuse(s) at the electrical box. Closed-loop or forked terminals with cord) ❒ UL-listed power cord - 30-amp - 240V -...• Do not use an extension cord or an adapter plug with this appliance. • The dryer must be supplied with upturned ends - 3-wire (for construction before 1996) or 4-wire (for gas dryers) TOOLS AND MATERIALS YOU WILL NEED FOR CONNECTING THE ELECTRICAL SUPPLY ❒ Flat-
Owners Manual
Page 24
...reduce the risk of birds or other concealed space of this manual. • Do not terminate exhaust in a chimney, a wall, a ceiling, gas vent, crawl space, attic, under an enclosed floor, or in or over the exhaust duct. • Wall caps must be tight to reduce ...wildlife. • Termination should present minimal resistance to the exhaust airflow and should be installed in accordance with the instructions found in "Connecting the Dryer to accumulate, creating a potential fire hazard. • Do not assemble ductwork with a kitchen exhaust system. This will serve as a collection ...
...reduce the risk of birds or other concealed space of this manual. • Do not terminate exhaust in a chimney, a wall, a ceiling, gas vent, crawl space, attic, under an enclosed floor, or in or over the exhaust duct. • Wall caps must be tight to reduce ...wildlife. • Termination should present minimal resistance to the exhaust airflow and should be installed in accordance with the instructions found in "Connecting the Dryer to accumulate, creating a potential fire hazard. • Do not assemble ductwork with a kitchen exhaust system. This will serve as a collection ...