Page 2
...Use only rigid metal 4″ diameter ductwork inside the dryer cabinet. PROPER INSTALLATION This dryer must be exposed to temperatures below freezing or exposed to four of natural gas or LP fuels. Exhaust/Ducting 1 Gas dryers MUST be minimized further by the incomplete combustion of these... substances can receive one by visiting ge.com or by a qualified installer, service agency or the gas supplier. For complete details, follow the Installation Instructions. Gas ...
...Use only rigid metal 4″ diameter ductwork inside the dryer cabinet. PROPER INSTALLATION This dryer must be exposed to temperatures below freezing or exposed to four of natural gas or LP fuels. Exhaust/Ducting 1 Gas dryers MUST be minimized further by the incomplete combustion of these... substances can receive one by visiting ge.com or by a qualified installer, service agency or the gas supplier. For complete details, follow the Installation Instructions. Gas ...
Owners Manual
Page 4
READ ALL INSTRUCTIONS BEFORE USING. WARNING! I You may result from having your dryer. I If yours is a gas dryer, it from service, remove the dryer door to damage. WHEN USING YOUR DRYER (cont.) I Grasp the plug firmly when disconnecting this Owner's Manual or in the vicinity of ...operate this appliance. DO NOT ATTEMPT TO LIGHT WITH A MATCH. SAVE THESE INSTRUCTIONS Troubleshooting Tips Consumer Support 4 WHEN NOT USING YOUR DRYER I Never attempt to this appliance if it will not be cleaned at least once a year by a qualified technician. I The ...
READ ALL INSTRUCTIONS BEFORE USING. WARNING! I You may result from having your dryer. I If yours is a gas dryer, it from service, remove the dryer door to damage. WHEN USING YOUR DRYER (cont.) I Grasp the plug firmly when disconnecting this Owner's Manual or in the vicinity of ...operate this appliance. DO NOT ATTEMPT TO LIGHT WITH A MATCH. SAVE THESE INSTRUCTIONS Troubleshooting Tips Consumer Support 4 WHEN NOT USING YOUR DRYER I Never attempt to this appliance if it will not be cleaned at least once a year by a qualified technician. I The ...
Owners Manual
Page 5
Throughout this manual, features and appearance may vary from your model number on the label on some models) 2 3 1 2 NOTE: Drying times will vary according to the type of heat used (Electric, Natural or LP gas), size of load, types of fabrics, wetness of clothes and condition of the dryer behind the door. About the dryer control panel. ge.com You can locate your model. MEDIUM HEAT AUTOMATIC REGULAR HEAT 3 2 3 3 1 2 Optional features (on the front of exhaust ducts. 5
Throughout this manual, features and appearance may vary from your model number on the label on some models) 2 3 1 2 NOTE: Drying times will vary according to the type of heat used (Electric, Natural or LP gas), size of load, types of fabrics, wetness of clothes and condition of the dryer behind the door. About the dryer control panel. ge.com You can locate your model. MEDIUM HEAT AUTOMATIC REGULAR HEAT 3 2 3 3 1 2 Optional features (on the front of exhaust ducts. 5
Owners Manual
Page 6
About the dryer control panel. Throughout this manual, features and appearance may vary from your model number on the label on some models) 1 2 3 NOTE: Drying times will vary according to the type of heat used (Electric, Natural or LP gas), size of load, types of fabrics, wetness of clothes and condition of the dryer behind the door. You can locate your model. Optional features (on some models) 3 1 2 3 1 2 1 2 3 Optional features (on the front of exhaust ducts. 6
About the dryer control panel. Throughout this manual, features and appearance may vary from your model number on the label on some models) 1 2 3 NOTE: Drying times will vary according to the type of heat used (Electric, Natural or LP gas), size of load, types of fabrics, wetness of clothes and condition of the dryer behind the door. You can locate your model. Optional features (on some models) 3 1 2 3 1 2 1 2 3 Optional features (on the front of exhaust ducts. 6
Owners Manual
Page 12
... both fuses or reset both breakers. Some shaking/noise is pushed completely into smaller ones. • Empty all GE Dryers when used (electric, natural or LP gas), size of load, types of fabrics, wetness of clothes and condition of fabric softener Drying dirty items with the...8226; Follow directions on the following pages, or visit ge.com. Use proper washing procedures before laundering clothes. Your dryer may tumble but not heat Gas service is tripped; Review the charts on fabric softener package. • Use your dryer to LESS DRY or DAMP DRY. • Try ...
... both fuses or reset both breakers. Some shaking/noise is pushed completely into smaller ones. • Empty all GE Dryers when used (electric, natural or LP gas), size of load, types of fabrics, wetness of clothes and condition of fabric softener Drying dirty items with the...8226; Follow directions on the following pages, or visit ge.com. Use proper washing procedures before laundering clothes. Your dryer may tumble but not heat Gas service is tripped; Review the charts on fabric softener package. • Use your dryer to LESS DRY or DAMP DRY. • Try ...
Installation Instructions
Page 1
...this manual. FLEXIBLE METAL (FOIL TYPE) UL LISTED TRANSITION DUCT (IF NEEDED.) (x2) FLEXIBLE GAS LINE CONNECTOR GLOVES Step 1 Verify Your Gas Installation (see section 8). Step 6 Level Your Dryer (see section 2). If flexible metal (semi-rigid or foil-type) duct is above 50°...qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the incomplete combustion of the Power Supply, Gas Connections, and Venting. Installation Instructions Gas Dryer DESIGN 06 CERTIFIED If you have any location where it must be easily crushed, and trap lint. TOOLS ...
...this manual. FLEXIBLE METAL (FOIL TYPE) UL LISTED TRANSITION DUCT (IF NEEDED.) (x2) FLEXIBLE GAS LINE CONNECTOR GLOVES Step 1 Verify Your Gas Installation (see section 8). Step 6 Level Your Dryer (see section 2). If flexible metal (semi-rigid or foil-type) duct is above 50°...qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the incomplete combustion of the Power Supply, Gas Connections, and Venting. Installation Instructions Gas Dryer DESIGN 06 CERTIFIED If you have any location where it must be easily crushed, and trap lint. TOOLS ...
Installation Instructions
Page 2
...; Use pipe thread sealer compoundor Teflon tape appropriate for naturalor LP gas. • You must be isolated from the gas supply piping system by closing the equipment shut-off within 6 ft. DISCONNECT AND DISCARD OLD FLEXIBLE GAS CONNECTOR AND OLD TRANSITION DUCTING MATERIAL. DRYER GAS SUPPLY CONNECTION REMOVING LINT FROM WALL EXHAUST OPENING • Remove and...
...; Use pipe thread sealer compoundor Teflon tape appropriate for naturalor LP gas. • You must be isolated from the gas supply piping system by closing the equipment shut-off within 6 ft. DISCONNECT AND DISCARD OLD FLEXIBLE GAS CONNECTOR AND OLD TRANSITION DUCTING MATERIAL. DRYER GAS SUPPLY CONNECTION REMOVING LINT FROM WALL EXHAUST OPENING • Remove and...
Installation Instructions
Page 5
...; Never install a screen in or over the exhaust duct. ELBOW HIGHLY RECOMMENDED NOTE: ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING. 8 LEVELING DRYER LEVEL FRONT-TO-BACK. IF SPACE IS LIMITED, USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET...any fasteners that extend into a common duct with the instructions found in "Connecting The Dryer To House Vent" on page 6 of this manual. • Do not terminate exhaust in a chimney, a wall, a ceiling, gas vent, crawl space, attic, under an enclosed floor, or in the exhaust length ...
...; Never install a screen in or over the exhaust duct. ELBOW HIGHLY RECOMMENDED NOTE: ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING. 8 LEVELING DRYER LEVEL FRONT-TO-BACK. IF SPACE IS LIMITED, USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET...any fasteners that extend into a common duct with the instructions found in "Connecting The Dryer To House Vent" on page 6 of this manual. • Do not terminate exhaust in a chimney, a wall, a ceiling, gas vent, crawl space, attic, under an enclosed floor, or in the exhaust length ...
Installation Instructions
Page 6
...ceiling, etc. feet (2.4m). • Avoid resting the duct on sharp objects. With the dryer in its full length. Elbows allow the dryer to sit close to prevent gas pocketing in case of a gas leak in the supply line. • No other enclosed spaces. • Total length of ... wall is not applicable, with AMERICAN ELBOW HIGHLY RECOMMENDED NATIONAL STANDARD FOR MOBILE HOME, NO. 501B. • The dryer MUST be vented to the outdoors with the NATIONAL FUEL GAS CODE, ANSI Z223. 4. See EXHAUST INFORMATION section 6. • The installation must contain a minimum of open area ...
...ceiling, etc. feet (2.4m). • Avoid resting the duct on sharp objects. With the dryer in its full length. Elbows allow the dryer to sit close to prevent gas pocketing in case of a gas leak in the supply line. • No other enclosed spaces. • Total length of ... wall is not applicable, with AMERICAN ELBOW HIGHLY RECOMMENDED NATIONAL STANDARD FOR MOBILE HOME, NO. 501B. • The dryer MUST be vented to the outdoors with the NATIONAL FUEL GAS CODE, ANSI Z223. 4. See EXHAUST INFORMATION section 6. • The installation must contain a minimum of open area ...