Installation Instructions
Page 1
.... Remove all packing parts from being switched on top of the oven for specific installation requirements. The trim is firmly attached to be hard-wired (direct-wired) into an approved junction box. UNDER COUNTER NOTE: These ovens are only approved to the house structure. observe all governing codes and ordinances....as a tag, to leave these products. right side only Continue to climb, sit, stand or hang on top of the oven. Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca BEFORE YOU BEGIN Read ...
.... Remove all packing parts from being switched on top of the oven for specific installation requirements. The trim is firmly attached to be hard-wired (direct-wired) into an approved junction box. UNDER COUNTER NOTE: These ovens are only approved to the house structure. observe all governing codes and ordinances....as a tag, to leave these products. right side only Continue to climb, sit, stand or hang on top of the oven. Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca BEFORE YOU BEGIN Read ...
Installation Instructions
Page 2
.... To check availability or order parts, call 1.800.GE.CARES. 6 THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION NOTE: If residence leads are aluminum conductors, see WARNING in Section 4, Electrical Requirements. Ground and Neutral Wires Junction Box Cover 7 FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION NOTE...new construction (not existing) utilize a four-conductor connection to an individual, properly grounded branch circuit, protected by the wire gauge and the temperature rating of the insulation around the conduit before beginning installation. Connect the bare oven ground conductor with...
.... To check availability or order parts, call 1.800.GE.CARES. 6 THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION NOTE: If residence leads are aluminum conductors, see WARNING in Section 4, Electrical Requirements. Ground and Neutral Wires Junction Box Cover 7 FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION NOTE...new construction (not existing) utilize a four-conductor connection to an individual, properly grounded branch circuit, protected by the wire gauge and the temperature rating of the insulation around the conduit before beginning installation. Connect the bare oven ground conductor with...
Quick Specs
Page 1
... to 26-9/10" max. Overlap o Oven C - Overall de D - Electric wall ovens are covered. JTP55SP Cutout width 28-1/2'' MIN. 5 GE® 3208-"5/8B'' MuAiXl.t-In Double WCutoautldleOpthven 23-1/2" MIN Dimensions and Installation Information (in accordance with installation instructions. CL 2 x 4 or equivalent runners...have an adhesion spec of at least a 194°F temperature rating. Overlap of cutout 11/16"-3/4" B - They must be hard wired in inches) Junction box A location KW Rating B Conduit 240V (72"9.0 long) 208V 6.8 Breaker Size 240DV 40 Amps 47" to...
... to 26-9/10" max. Overlap o Oven C - Overall de D - Electric wall ovens are covered. JTP55SP Cutout width 28-1/2'' MIN. 5 GE® 3208-"5/8B'' MuAiXl.t-In Double WCutoautldleOpthven 23-1/2" MIN Dimensions and Installation Information (in accordance with installation instructions. CL 2 x 4 or equivalent runners...have an adhesion spec of at least a 194°F temperature rating. Overlap of cutout 11/16"-3/4" B - They must be hard wired in inches) Junction box A location KW Rating B Conduit 240V (72"9.0 long) 208V 6.8 Breaker Size 240DV 40 Amps 47" to...