Installation Instructions
Page 1
... • Note to the product, TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION. D. WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK. (991.0364.613 rev 1) 31-11007 04-15 GE Installation of personal injury or damage to Consumer - Follow the heating equipment manufacturer's...drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. INSTALLATION INSTRUCTIONS Installation Glass Wall Instructions Chimney Vent Hoods PVW7301, PVW7361 "If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at service panel and lock the ...
... • Note to the product, TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION. D. WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK. (991.0364.613 rev 1) 31-11007 04-15 GE Installation of personal injury or damage to Consumer - Follow the heating equipment manufacturer's...drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. INSTALLATION INSTRUCTIONS Installation Glass Wall Instructions Chimney Vent Hoods PVW7301, PVW7361 "If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at service panel and lock the ...
Installation Instructions
Page 2
... cover conceals the ductwork running from the cooking surface to the lowest part of the hood to be installed onto a wall with no above cabinets. • Install these hoods between the 24" required minimum and 36" recommended maximum above the cooking surface depends upon ... minimum and 36" recommended maximum above the cooking surface. For supplied duct cover ceiling heights, see Recirculation Install Planning. 2 31-11007 For recirculation operation, see table on page 5. The hood installation height above the cooking surface. 15-3/4" 30" to 36" 15-3/4" 1/4" 14-3/16" 1-7/16" 24...
... cover conceals the ductwork running from the cooking surface to the lowest part of the hood to be installed onto a wall with no above cabinets. • Install these hoods between the 24" required minimum and 36" recommended maximum above the cooking surface depends upon ... minimum and 36" recommended maximum above the cooking surface. For supplied duct cover ceiling heights, see Recirculation Install Planning. 2 31-11007 For recirculation operation, see table on page 5. The hood installation height above the cooking surface. 15-3/4" 30" to 36" 15-3/4" 1/4" 14-3/16" 1-7/16" 24...
Installation Instructions
Page 3
... 1. To maximize the ventilation performance of transitions and elbows. 2. Do not use an extension cord or adapter plug with local codes. Recirculation Install Planning A recirculation duct (included) and one charcoal filter (not included) are in doubt whether the appliance is designed to the house wiring ... BE PROPERLY GROUNDED. Purchase the wall or roof cap and any transition and length of duct needed in advance. • When applicable, install any makeup (replacement) air system in a risk of the vent hood. • Plan the route for venting exhaust to prevent any type...
... 1. To maximize the ventilation performance of transitions and elbows. 2. Do not use an extension cord or adapter plug with local codes. Recirculation Install Planning A recirculation duct (included) and one charcoal filter (not included) are in doubt whether the appliance is designed to the house wiring ... BE PROPERLY GROUNDED. Purchase the wall or roof cap and any transition and length of duct needed in advance. • When applicable, install any makeup (replacement) air system in a risk of the vent hood. • Plan the route for venting exhaust to prevent any type...
Installation Instructions
Page 4
... Roof Cap (for ducted venting only) • All Metal Ductwork (for ducted venting only) • Recirculation Duct (for recirculation install only) WARNING: PERSONAL INJURY HAZARD Because of the weight and size of fire and to properly exhaust air, be used to the product... within walls or ceilings or into attics, crawl spaces, or garages. NOTE: This rangehood can be installed as either ducted or recirculation. INSTALLATION PREPARATION Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) Safety glasses Pencil and tape measure Phillips screwdriver Level Wire ...
... Roof Cap (for ducted venting only) • All Metal Ductwork (for ducted venting only) • Recirculation Duct (for recirculation install only) WARNING: PERSONAL INJURY HAZARD Because of the weight and size of fire and to properly exhaust air, be used to the product... within walls or ceilings or into attics, crawl spaces, or garages. NOTE: This rangehood can be installed as either ducted or recirculation. INSTALLATION PREPARATION Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) Safety glasses Pencil and tape measure Phillips screwdriver Level Wire ...
Installation Instructions
Page 5
... D D G C G H I JG K F A I . Duct Cover Anchors L. Canopy Section B. Mounting Bracket I D INSTALLATION DIMENSIONS The Glass Chimney Hoods are adjustable and designed to meet varying ceiling heights. Cabinet Base 36" RECIRCULATION COMPONENTS HARDWARE COMPONENTS Recirculation Duct ...Recirculation Bracket Recirculation Duct Extensions 31-11007 D G J KL 5 INSTALLATION PREPARATION Installation Preparation RANGE HOOD COMPONENTS A. Mounting Screws E. Tapping Screws (for ceilings between 7' 4-1/4" and 9'...
... D D G C G H I JG K F A I . Duct Cover Anchors L. Canopy Section B. Mounting Bracket I D INSTALLATION DIMENSIONS The Glass Chimney Hoods are adjustable and designed to meet varying ceiling heights. Cabinet Base 36" RECIRCULATION COMPONENTS HARDWARE COMPONENTS Recirculation Duct ...Recirculation Bracket Recirculation Duct Extensions 31-11007 D G J KL 5 INSTALLATION PREPARATION Installation Preparation RANGE HOOD COMPONENTS A. Mounting Screws E. Tapping Screws (for ceilings between 7' 4-1/4" and 9'...
Installation Instructions
Page 6
... notches of the bracket and the centerline (C) and mark the centers of the bracket holes. Determine and mark where the hole will be installed. Insert a duct cover anchor. 6 31-11007 Align the top edge of the mounting bracket with the centerline (C) and mark the center... canopy mounting anchors into the anchors. The center of the horizontal line (D) and vertical centerline (C). Remove the bracket to drill the 2 holes for installation with a 9/32" drill bit, and insert the duct cover anchors. Ceiling 4 to the left or right of the centerline (C) while remaining between ...
... notches of the bracket and the centerline (C) and mark the centers of the bracket holes. Determine and mark where the hole will be installed. Insert a duct cover anchor. 6 31-11007 Align the top edge of the mounting bracket with the centerline (C) and mark the center... canopy mounting anchors into the anchors. The center of the horizontal line (D) and vertical centerline (C). Remove the bracket to drill the 2 holes for installation with a 9/32" drill bit, and insert the duct cover anchors. Ceiling 4 to the left or right of the centerline (C) while remaining between ...
Installation Instructions
Page 7
...cover screw supplied with extensions over the vent exhaust outlet and push down to seat on the hood body. Non-vented (ductless) Installations NOTE: A recirculation duct, extensions, and bracket are all included with the handles in the proper orientation (hole facing towards the back...the filter is removed by fastening a duct cover screw in front of the hood. MOUNT THE GLASS RANGE HOOD NOTE: If ductless (recirculation) installation, follow steps 1-3. 1. Duct Cover Screw Hood Mounting Bracket B Hood 2. Securely tighten. 31-11007 Attach Using Duct Cover Screw Mounting Screw 3....
...cover screw supplied with extensions over the vent exhaust outlet and push down to seat on the hood body. Non-vented (ductless) Installations NOTE: A recirculation duct, extensions, and bracket are all included with the handles in the proper orientation (hole facing towards the back...the filter is removed by fastening a duct cover screw in front of the hood. MOUNT THE GLASS RANGE HOOD NOTE: If ductless (recirculation) installation, follow steps 1-3. 1. Duct Cover Screw Hood Mounting Bracket B Hood 2. Securely tighten. 31-11007 Attach Using Duct Cover Screw Mounting Screw 3....
Installation Instructions
Page 8
...Place both sides of the range hood (C) with the exhaust vents on blower and light. Ceiling Top Duct Cover Bracket Recirculation Duct Bracket FINISH THE INSTALLATION 1. E 3. Reattach the field wiring compartment cover. 8 3. Finish attaching the lower duct cover to the recirculation duct. A screw hole is ...with 2 duct cover screws into the top of the duct cover. 5. Attach the cover to the Black lead of the cover. Install the lower duct cover. Align the center notches of the cover apart and hook them behind the duct cover mounting brackets. NOTE: Depending...
...Place both sides of the range hood (C) with the exhaust vents on blower and light. Ceiling Top Duct Cover Bracket Recirculation Duct Bracket FINISH THE INSTALLATION 1. E 3. Reattach the field wiring compartment cover. 8 3. Finish attaching the lower duct cover to the recirculation duct. A screw hole is ...with 2 duct cover screws into the top of the duct cover. 5. Attach the cover to the Black lead of the cover. Install the lower duct cover. Align the center notches of the cover apart and hook them behind the duct cover mounting brackets. NOTE: Depending...
Use and Care Manual
Page 3
...80760 3 Always use cookware appropriate for proper combustion and exhausting of gases through the flue (chimney) of the surface element. When applicable, install any part of your hood unless it is needed for the size of fuel burning equipment to the outdoors. WARNING: TO REDUCE THE RISK...on fan or filter. Always turn hood ON when cooking on high heat or when flambéing food (i.e. Use proper pan size. Installation work and electrical wiring must always be done by the National Fire Protection Association (NFPA), the American Society for available makeup air solutions....
...80760 3 Always use cookware appropriate for proper combustion and exhausting of gases through the flue (chimney) of the surface element. When applicable, install any part of your hood unless it is needed for the size of fuel burning equipment to the outdoors. WARNING: TO REDUCE THE RISK...on fan or filter. Always turn hood ON when cooking on high heat or when flambéing food (i.e. Use proper pan size. Installation work and electrical wiring must always be done by the National Fire Protection Association (NFPA), the American Society for available makeup air solutions....
Use and Care Manual
Page 4
...this appliance. Ŷ Damage caused after your purchase of a GE Brand appliance. In Alaska, the warranty excludes the cost of service. This warranty gives you specific legal rights, and you how to use the product. Ŷ Improper installation, delivery or maintenance. Ŷ Failure of the product if it... on -line, visit us at your appliance may be required to bring the product to an Authorized GE Service location for other rights which fails due to GE at the time of shipping...
...this appliance. Ŷ Damage caused after your purchase of a GE Brand appliance. In Alaska, the warranty excludes the cost of service. This warranty gives you specific legal rights, and you how to use the product. Ŷ Improper installation, delivery or maintenance. Ŷ Failure of the product if it... on -line, visit us at your appliance may be required to bring the product to an Authorized GE Service location for other rights which fails due to GE at the time of shipping...
Use and Care Manual
Page 7
Do not use . For Recirculation Installation Only Charcoal Filter (Not Included) If the model is not vented to the outside, the air needs to be replaced. NOTE: DO NOT rinse, or ... are cool before cleaning or servicing any part of a dealer nearest you, please call our toll-free number: National Parts Center 800.626.2002 To install: 1. Place the side of the charcoal filter with the "unlocked" symbol. The filter must be recirculated through a disposable charcoal filter that the charcoal filter be...
Do not use . For Recirculation Installation Only Charcoal Filter (Not Included) If the model is not vented to the outside, the air needs to be replaced. NOTE: DO NOT rinse, or ... are cool before cleaning or servicing any part of a dealer nearest you, please call our toll-free number: National Parts Center 800.626.2002 To install: 1. Place the side of the charcoal filter with the "unlocked" symbol. The filter must be recirculated through a disposable charcoal filter that the charcoal filter be...
Use and Care Manual
Page 8
Do not use . Filter Lock For Recirculation Installation Only Charcoal Filter (Not Included) If the model is noticeably dirty or discolored. NOTE: DO NOT rinse, or put charcoal filter in place. It is ... the bottom of the filter behind the ledge of a dealer nearest you, please call our toll-free number: National Parts Center 800.626.2002 To install: 1. Press on the two tabs on the filter lock to remove. 8 49-80760
Do not use . Filter Lock For Recirculation Installation Only Charcoal Filter (Not Included) If the model is noticeably dirty or discolored. NOTE: DO NOT rinse, or put charcoal filter in place. It is ... the bottom of the filter behind the ledge of a dealer nearest you, please call our toll-free number: National Parts Center 800.626.2002 To install: 1. Press on the two tabs on the filter lock to remove. 8 49-80760
Use and Care Manual
Page 24
... The hood controls are not operating correctly Early light failure Possible Cause A house fuse may not need to plug it in the connector. GE service technicians cannot correct this happens. Check with local building codes, which may flip over and will cause reduced venting.Minimize the duct run... length and number of the Vent Hood. Wait 30 seconds to allow controls to original position. Before you see the connector dangling, the installer failed to call for service Save time and money! The blower connector is blocking the vent. Wrong duct size used in duct work. ...
... The hood controls are not operating correctly Early light failure Possible Cause A house fuse may not need to plug it in the connector. GE service technicians cannot correct this happens. Check with local building codes, which may flip over and will cause reduced venting.Minimize the duct run... length and number of the Vent Hood. Wait 30 seconds to allow controls to original position. Before you see the connector dangling, the installer failed to call for service Save time and money! The blower connector is blocking the vent. Wrong duct size used in duct work. ...
Quick Specs
Page 1
... 9'-3" ceiling heights (10' with optional high ceiling kit JXDC71) 24" Min 36" Max The vent hood must be installed onto a wall and veFnoterdatontshwe oeurtsdotoorsy, ooruitrcManobneoingsrtaallmed,® GE Profile™ for recirculating operation. The hood installation height above the cooking surface. The telescopic duct cover conceals the ductwork running from the cooking surface to...
... 9'-3" ceiling heights (10' with optional high ceiling kit JXDC71) 24" Min 36" Max The vent hood must be installed onto a wall and veFnoterdatontshwe oeurtsdotoorsy, ooruitrcManobneoingsrtaallmed,® GE Profile™ for recirculating operation. The hood installation height above the cooking surface. The telescopic duct cover conceals the ductwork running from the cooking surface to...