... Windows 7 Beta * - Driver included in Windows 7 Beta * - Driver available from Windows Update 2008 Video Audio SMBUS NIC Models Controller (chipset) dc7900 dc5800 dc5850 dx7400 * dx7500 No dx7510 No Intel HECI No N/A Intel SOL TPM Module No N/A Note: Driver availability is subject to..., audio, SMBUS Controller, NIC, Intel HECI, Intel SOL, TPM module. 2007 & Video Audio SMBUS NIC prior Controller Models (chipset) dc7700 Intel HECI No Intel SOL TPM Module No dc7800 dc5700 No No dc5750 * N/A N/A Note: Driver availability is subject to change . -
... Windows 7 Beta * - Driver included in Windows 7 Beta * - Driver available from Windows Update 2008 Video Audio SMBUS NIC Models Controller (chipset) dc7900 dc5800 dc5850 dx7400 * dx7500 No dx7510 No Intel HECI No N/A Intel SOL TPM Module No N/A Note: Driver availability is subject to..., audio, SMBUS Controller, NIC, Intel HECI, Intel SOL, TPM module. 2007 & Video Audio SMBUS NIC prior Controller Models (chipset) dc7700 Intel HECI No Intel SOL TPM Module No dc7800 dc5700 No No dc5750 * N/A N/A Note: Driver availability is subject to change . -
Illustrated Parts & Service Map: HP Compaq dc5850 Microtower Business PC
Page 4
... Ensure memory modules are installed properly. 3. For optimal performance, the SATA 0 and SATA 1 connectors must be problem with the chipset. 1. Drivelock is incompatible with expansion card. 6. Either remove the Drivelocked SATA device or disable the Drivelock feature. Replace keyboard.... 3. channel has the same amount of the computer. Reseat chassis, rear chassis, or front chassis fan. 2. HP Insight Diagnostics The HP Insight Diagnostics utility allows you to view information about the computer. Other tabs provide additional information, including diagnostic test options...
... Ensure memory modules are installed properly. 3. For optimal performance, the SATA 0 and SATA 1 connectors must be problem with the chipset. 1. Drivelock is incompatible with expansion card. 6. Either remove the Drivelocked SATA device or disable the Drivelock feature. Replace keyboard.... 3. channel has the same amount of the computer. Reseat chassis, rear chassis, or front chassis fan. 2. HP Insight Diagnostics The HP Insight Diagnostics utility allows you to view information about the computer. Other tabs provide additional information, including diagnostic test options...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 3
... Sources 1-1 1.3 Serial Number 1-2 1.4 Notational Conventions 1-2 1.5.1 Special Notices 1-2 1.5.2 Values 1-2 1.5.2 Ranges 1-2 1.5 Common Acronyms and Abbreviations 1-3 2 System Overview 2.1 Introduction 2-1 2.2 Features 2-2 2.3 System Architecture 2-4 2.3.1 AMD Processor Support 2-6 2.3.2 Chipset 2-6 2.3.3 Support Components 2-7 2.3.4 System Memory 2-7 2.3.5 Mass Storage 2-8 2.3.6 Serial Interface 2-8 2.3.7 Universal Serial Bus Interface 2-8 2.3.8 Network Interface Controller 2-8 2.3.9 Integrated Graphics Processor 2-9 2.3.10 Audio Subsystem 2-9 2.4 Specifications 2-10...
... Sources 1-1 1.3 Serial Number 1-2 1.4 Notational Conventions 1-2 1.5.1 Special Notices 1-2 1.5.2 Values 1-2 1.5.2 Ranges 1-2 1.5 Common Acronyms and Abbreviations 1-3 2 System Overview 2.1 Introduction 2-1 2.2 Features 2-2 2.3 System Architecture 2-4 2.3.1 AMD Processor Support 2-6 2.3.2 Chipset 2-6 2.3.3 Support Components 2-7 2.3.4 System Memory 2-7 2.3.5 Mass Storage 2-8 2.3.6 Serial Interface 2-8 2.3.7 Universal Serial Bus Interface 2-8 2.3.8 Network Interface Controller 2-8 2.3.9 Integrated Graphics Processor 2-9 2.3.10 Audio Subsystem 2-9 2.4 Specifications 2-10...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 7
... also allow the user to view the color shading used either as an online document or in detail the ... Organization (SATA-IO): www.serialATA.org. ■ USB user group: www.usb.org Technical Reference Guide www.hp.com 1-1 at no charge from the .pdf file. The chapters of this Guide This guide provides technical information about.... The appendices contain general data such as error codes and information about HP Compaq dc5850 Business PC personal computers that feature AMD processors and the AMD 780V chipset. 1 Introduction 1.1 About this guide may be obtained by printing from ...
... also allow the user to view the color shading used either as an online document or in detail the ... Organization (SATA-IO): www.serialATA.org. ■ USB user group: www.usb.org Technical Reference Guide www.hp.com 1-1 at no charge from the .pdf file. The chapters of this Guide This guide provides technical information about.... The appendices contain general data such as error codes and information about HP Compaq dc5850 Business PC personal computers that feature AMD processors and the AMD 780V chipset. 1 Introduction 1.1 About this guide may be obtained by printing from ...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 17
... Business PCs This chapter includes the following topics: ■ Features (2.2) ■ System architecture (2.3) ■ Specifications (2.4) HP dc5850 Small Form Factor Technical Reference Guide www.hp.com 2-1 Based on an AMD processor with the AMD 780V chipset, these systems emphasize performance along with the needs of manageability, serviceability, and compatibility for enterprise environments. All...
... Business PCs This chapter includes the following topics: ■ Features (2.2) ■ System architecture (2.3) ■ Specifications (2.4) HP dc5850 Small Form Factor Technical Reference Guide www.hp.com 2-1 Based on an AMD processor with the AMD 780V chipset, these systems emphasize performance along with the needs of manageability, serviceability, and compatibility for enterprise environments. All...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 18
...™ Dual-Core with HyperTransport Technology ❏ AMD Athlon Single-Core with HyperTransport Technology ❏ AMD Sempron™ with HyperTransport Technology ■ AMD 780V chipset ■ ATI Radeon 3100 integrated graphics processor with dual monitor support: ❏ One VGA connector ❏ One DVI-D connector ■ 667-, 800-,...Block ❏ Diskette drive disable, boot disable, write protect ❏ Power-on and Administrator passwords ❏ Serial and USB port disable ❏ HP Virtual Safe Browser ■ PS/2 enhanced keyboard and optical scroll mouse 2-2 www...
...™ Dual-Core with HyperTransport Technology ❏ AMD Athlon Single-Core with HyperTransport Technology ❏ AMD Sempron™ with HyperTransport Technology ■ AMD 780V chipset ■ ATI Radeon 3100 integrated graphics processor with dual monitor support: ❏ One VGA connector ❏ One DVI-D connector ■ 667-, 800-,...Block ❏ Diskette drive disable, boot disable, write protect ❏ Power-on and Administrator passwords ❏ Serial and USB port disable ❏ HP Virtual Safe Browser ■ PS/2 enhanced keyboard and optical scroll mouse 2-2 www...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 20
...The systems covered in this guide include the following key components: ■ AMD Phenom, Athlon, or Sempron processor. ■ AMD 780V chipset (includes RS780 north bridge and SB700 south bridge) ■ SCH5327 Super I/O (SIO) controller supporting PS/2 keyboard and mouse peripherals ...serial ATA (SATA) hard drive in this guide feature an architecture based on an AMD processor and chipset (Figure 2-2). All systems covered in the standard configuration. 2-4 www.hp.com Technical Reference Guide The RS780 north bridge communicates with the processor through a PCI Express (PCIe...
...The systems covered in this guide include the following key components: ■ AMD Phenom, Athlon, or Sempron processor. ■ AMD 780V chipset (includes RS780 north bridge and SB700 south bridge) ■ SCH5327 Super I/O (SIO) controller supporting PS/2 keyboard and mouse peripherals ...serial ATA (SATA) hard drive in this guide feature an architecture based on an AMD processor and chipset (Figure 2-2). All systems covered in the standard configuration. 2-4 www.hp.com Technical Reference Guide The RS780 north bridge communicates with the processor through a PCI Express (PCIe...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 22
..., 2 internal) 2-6 www.hp.com Technical Reference Guide Exceeding this guide are backward-compatible with HyperTransport Technology All processors include an integrated DDR2 memory controller and support up to 95 watts. Table 2-2 compares the functions provided by the chipsets. CAUTION: These systems can ...with software written for detailed removal and replacement procedures of the heatsink/fan assembly and the processor 2.3.2 Chipset The AMD 780V chipset consists of the processor heatsink is critical in a zero-insertion-force (ZIF) AMD AM2+ socket. Components RS780C SB700...
..., 2 internal) 2-6 www.hp.com Technical Reference Guide Exceeding this guide are backward-compatible with HyperTransport Technology All processors include an integrated DDR2 memory controller and support up to 95 watts. Table 2-2 compares the functions provided by the chipsets. CAUTION: These systems can ...with software written for detailed removal and replacement procedures of the heatsink/fan assembly and the processor 2.3.2 Chipset The AMD 780V chipset consists of the processor heatsink is critical in a zero-insertion-force (ZIF) AMD AM2+ socket. Components RS780C SB700...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 23
... analog-to-digital stereo converters Analog I /F Broadcom BMC5754 Network Interface Controller 10/100/1000 Fast Ethernet network interface controller. Technical Reference Guide www.hp.com 2-7 Table 2-3 Support Component Functions Component Name Function SCH5327 SIO Controller Keyboard and pointing device I/F Diskette I/F Serial I/F (COM1and COM2) [1]...models support DDR2 800- System Overview 2.3.3 Support Components Input/output functions not provided by the chipset are NOT interchangeable. Some of memory. ✎ DDR and DDR2 DIMMs are handled by other functions as well.
... analog-to-digital stereo converters Analog I /F Broadcom BMC5754 Network Interface Controller 10/100/1000 Fast Ethernet network interface controller. Technical Reference Guide www.hp.com 2-7 Table 2-3 Support Component Functions Component Name Function SCH5327 SIO Controller Keyboard and pointing device I/F Diskette I/F Serial I/F (COM1and COM2) [1]...models support DDR2 800- System Overview 2.3.3 Support Components Input/output functions not provided by the chipset are NOT interchangeable. Some of memory. ✎ DDR and DDR2 DIMMs are handled by other functions as well.
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 25
Table 2-4 lists the key features of the chipset and the ADI AD1884A High Definition audio codec. PCI Express Memory Amount 128 or 256 MB pre-allocated Memory Type DVMT 3.0 DAC Speed 300 MHz.... HD audio provides enhanced audio performance with higher sampling rates, refined signal interfaces, and audio processors with the F10 BIOS control. Technical Reference Guide www.hp.com 2-9 System Overview 2.3.9 Integrated Graphics Processor These systems use the integrated High Definition audio controller of the integrated graphics processor. Table 2-4 Integrated Graphics Subsystem ...
Table 2-4 lists the key features of the chipset and the ADI AD1884A High Definition audio codec. PCI Express Memory Amount 128 or 256 MB pre-allocated Memory Type DVMT 3.0 DAC Speed 300 MHz.... HD audio provides enhanced audio performance with higher sampling rates, refined signal interfaces, and audio processors with the F10 BIOS control. Technical Reference Guide www.hp.com 2-9 System Overview 2.3.9 Integrated Graphics Processor These systems use the integrated High Definition audio controller of the integrated graphics processor. Table 2-4 Integrated Graphics Subsystem ...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 29
...Sempron processor families. As shown in Figure 3-1, these processors use an integrated DDR2 memory controller and communicate with the chipset through the HyperTranport interface (I /F North Bridge DIMM XMM2 DIMM DIMM XMM4 Figure 3-1. Processor/Memory Subsystem Architecture This ...chapter includes the following topics: ■ AMD processors (3.2) ■ Memory subsystem (3.3) Technical Reference Guide www.hp.com 3-1 XMM1 XMM3 DIMM AMD Processor Core(s) L2 Cache Channel A DDR2 Controller Channel B HyperTransport I /F). 3 Processor/Memory ...
...Sempron processor families. As shown in Figure 3-1, these processors use an integrated DDR2 memory controller and communicate with the chipset through the HyperTranport interface (I /F North Bridge DIMM XMM2 DIMM DIMM XMM4 Figure 3-1. Processor/Memory Subsystem Architecture This ...chapter includes the following topics: ■ AMD processors (3.2) ■ Memory subsystem (3.3) Technical Reference Guide www.hp.com 3-1 XMM1 XMM3 DIMM AMD Processor Core(s) L2 Cache Channel A DDR2 Controller Channel B HyperTransport I /F). 3 Processor/Memory ...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 35
... 4.2.1 PCI 2.3 Bus Operation The PCI 2.3 bus consists of a 32-bit path (AD31-00 lines) that device by off-the-shelf chipsets and therefore describes only basic aspects of these functions as well as described in the PCI Local Bus specification Rev. 2.3) is achieved during burst... web site: www.pcisig.com. For detailed information regarding PCI bus operation, refer to the systems covered in this guide. Technical Reference Guide www.hp.com 4-1 For detailed information on the PCI bus must comply with each cycle requiring a clock (PCICLK) cycle. High performance is employed. 4...
... 4.2.1 PCI 2.3 Bus Operation The PCI 2.3 bus consists of a 32-bit path (AD31-00 lines) that device by off-the-shelf chipsets and therefore describes only basic aspects of these functions as well as described in the PCI Local Bus specification Rev. 2.3) is achieved during burst... web site: www.pcisig.com. For detailed information regarding PCI bus operation, refer to the systems covered in this guide. Technical Reference Guide www.hp.com 4-1 For detailed information on the PCI bus must comply with each cycle requiring a clock (PCICLK) cycle. High performance is employed. 4...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 37
... 3). 4.2.4 PCI Interrupts Eight interrupt signals (INTA- During the initialization process, two PCI Express devices will negotiate for use by the chipset and allows compliant PCI peripherals to initiate the power management routine. one for transmit, one for scalability depending on -board PCI devices ...for the number of lanes available and the speed the link can provide a data flow of signal paths; Technical Reference Guide www.hp.com 4-3 System Support Link Layer The link layer provides data integrity by adding a sequence information prefix and a CRC suffix to the...
... 3). 4.2.4 PCI Interrupts Eight interrupt signals (INTA- During the initialization process, two PCI Express devices will negotiate for use by the chipset and allows compliant PCI peripherals to initiate the power management routine. one for transmit, one for scalability depending on -board PCI devices ...for the number of lanes available and the speed the link can provide a data flow of signal paths; Technical Reference Guide www.hp.com 4-3 System Support Link Layer The link layer provides data integrity by adding a sequence information prefix and a CRC suffix to the...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 45
...Suspend or soft-off Serial Port Ring Suspend or soft-off USB Suspend only Keyboard Suspend only Mouse Suspend only Technical Reference Guide www.hp.com 4-11 The ACPI wake-up ") by events defined by user control. System Support 4.5.2 Power Management These systems provide baseline ...hardware support of ACPI-compliant firmware and software. Key power-consuming components (processor, chipset, I/O controller, and fan) can then be placed into a reduced power mode either automatically or by the ACPI 2.0 specification.
...Suspend or soft-off Serial Port Ring Suspend or soft-off USB Suspend only Keyboard Suspend only Mouse Suspend only Technical Reference Guide www.hp.com 4-11 The ACPI wake-up ") by events defined by user control. System Support 4.5.2 Power Management These systems provide baseline ...hardware support of ACPI-compliant firmware and software. Key power-consuming components (processor, chipset, I/O controller, and fan) can then be placed into a reduced power mode either automatically or by the ACPI 2.0 specification.
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 75
...; Signal distribution (7.4) 7.2 Power Distribution Each form factor uses a unique power supply unit (PSU). Front Bezel System Board Power Button Power On CPU, slots, Chipsets, Logic, & Voltage Regulators 90 - 264 VAC POK PS On +3.3 VDC 5 AUX +5 VDC +12 VDC +12 VccP -12 VDC +3.3 VDC +5... Figure 7-1. The PSUs are not interchangeable between the SFF and MT form factors. Power Generation Block Diagram Technical Reference Guide www.hp.com 7-1 These systems use a power supply assembly contained within the system chassis. 7 Power and Signal Distribution 7.1 Introduction This ...
...; Signal distribution (7.4) 7.2 Power Distribution Each form factor uses a unique power supply unit (PSU). Front Bezel System Board Power Button Power On CPU, slots, Chipsets, Logic, & Voltage Regulators 90 - 264 VAC POK PS On +3.3 VDC 5 AUX +5 VDC +12 VDC +12 VccP -12 VDC +3.3 VDC +5... Figure 7-1. The PSUs are not interchangeable between the SFF and MT form factors. Power Generation Block Diagram Technical Reference Guide www.hp.com 7-1 These systems use a power supply assembly contained within the system chassis. 7 Power and Signal Distribution 7.1 Introduction This ...
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 92
... delay and/or typematic rate of a USB keyboard though BIOS function INT 16 is not supported. 8.7 Management Functions The management functions of the AMD 780V chipset allow a system unit to be used during POST, for the presence of a USB keyboard. SYSTEM BIOS 8.6 USB Legacy Support The system BIOS ROM checks ... the following alerts: ■ Temperature alert ■ Fan failure alert ■ Chassis intrusion alert ■ Watchdog timer alert ■ No memory installed alert 8-8 www.hp.com Technical Reference Guide This allows a system with an OS that does not include a USB driver.
... delay and/or typematic rate of a USB keyboard though BIOS function INT 16 is not supported. 8.7 Management Functions The management functions of the AMD 780V chipset allow a system unit to be used during POST, for the presence of a USB keyboard. SYSTEM BIOS 8.6 USB Legacy Support The system BIOS ROM checks ... the following alerts: ■ Temperature alert ■ Fan failure alert ■ Chassis intrusion alert ■ Watchdog timer alert ■ No memory installed alert 8-8 www.hp.com Technical Reference Guide This allows a system with an OS that does not include a USB driver.
Technical Reference Guide: HP Compaq dc5850 Series Business Desktop Computers
Page 113
...1-1, 2-1, 2-6, 3-1, 3-2 APIC Mode 4-6 Audio codec 2-9, 5-13, 5-14 Audio Specifications 5-15 B BIOS upgrading 8-2 boot device order 8-3 Boot error codes4-2, 8-4 bus master (PCI) 4-2 C chipset 2-6 CMOS 4-8 CMOS, clearing 4-8 configuration memory 4-8 D DB-25 connector 5-8 DB-9 connector 5-6 DDR2 SDRAM 3-3 DIMM socket 3-3 Direct Memory Access (DMA) 4-7 Diskette Drive Connector 5-5 diskette drive...mass storage 2-8 Memory, system 2-7, 3-3 memory allocation 3-4, 6-2 memory map 3-5 microphone in (audio interface) 5-13 mouse (pointing device) interface 5-10 Technical Reference Guide www.hp.com Index-1
...1-1, 2-1, 2-6, 3-1, 3-2 APIC Mode 4-6 Audio codec 2-9, 5-13, 5-14 Audio Specifications 5-15 B BIOS upgrading 8-2 boot device order 8-3 Boot error codes4-2, 8-4 bus master (PCI) 4-2 C chipset 2-6 CMOS 4-8 CMOS, clearing 4-8 configuration memory 4-8 D DB-25 connector 5-8 DB-9 connector 5-6 DDR2 SDRAM 3-3 DIMM socket 3-3 Direct Memory Access (DMA) 4-7 Diskette Drive Connector 5-5 diskette drive...mass storage 2-8 Memory, system 2-7, 3-3 memory allocation 3-4, 6-2 memory map 3-5 microphone in (audio interface) 5-13 mouse (pointing device) interface 5-10 Technical Reference Guide www.hp.com Index-1
Service Reference Guide: HP Compaq dc5850 Business PC
Page 188
...is not optimized. Replace the system board. 176 Appendix C POST Error Messages If third-party memory has been added, test using HP-only memory. 4. Ensure memory modules are installed properly. 3. Remove and replace the identified faulty memory module(s). 5. If the error... Socket(s) X, X, ... Rearrange the DIMMs so that none of memory. 215-DIMM Configuration Error Populated DIMM configuration is incompatible with the chipset. 1. Check connector for memory support information. 301-Keyboard Error Keyboard failure. 1. Verify proper memory module type. 2. If additional memory...
...is not optimized. Replace the system board. 176 Appendix C POST Error Messages If third-party memory has been added, test using HP-only memory. 4. Ensure memory modules are installed properly. 3. Remove and replace the identified faulty memory module(s). 5. If the error... Socket(s) X, X, ... Rearrange the DIMMs so that none of memory. 215-DIMM Configuration Error Populated DIMM configuration is incompatible with the chipset. 1. Check connector for memory support information. 301-Keyboard Error Keyboard failure. 1. Verify proper memory module type. 2. If additional memory...
Troubleshooting Guide
Page 56
If third-party memory has been added, test using HP-only memory. 4. Run Computer Setup or Windows utilities. 2. If the error persists after replacing memory modules, replace the system board. 213-Incompatible Memory ... module type. 201-Memory Error RAM failure. 1. Verify proper memory module type. 2. If additional memory was recently ECC memory error correction. Replace DIMM with the chipset. 1. Check connector for memory support information. 301-Keyboard Error Keyboard failure. 1. Run Computer Setup or Windows utilities. 2. Table A-1 Numeric Codes and Text Messages (...
If third-party memory has been added, test using HP-only memory. 4. Run Computer Setup or Windows utilities. 2. If the error persists after replacing memory modules, replace the system board. 213-Incompatible Memory ... module type. 201-Memory Error RAM failure. 1. Verify proper memory module type. 2. If additional memory was recently ECC memory error correction. Replace DIMM with the chipset. 1. Check connector for memory support information. 301-Keyboard Error Keyboard failure. 1. Run Computer Setup or Windows utilities. 2. Table A-1 Numeric Codes and Text Messages (...
AHCI and RAID on HP Compaq dc5850 Business PCs
Page 2
... Attachment (SATA) and the integration of HP Compaq dc5850 Business PCs, and other supported RAID configurations. Mirroring is 100% duplication of AHCI and RAID Technology Definitions Table 1 Basic AHCI and RAID Definitions AHCI ATA BIOS Chipset HDD IDE Advanced Host Controller Interface, a...Electronics. 2 This white paper provides a basic overview of RAID technology, supported factory configurations of RAID into AMD's RS780 and SB700 chipsets. RAID systems may have RAID controllers. Term used to define a collection of Independent Disks) is used with servers, desktop PCs are...
... Attachment (SATA) and the integration of HP Compaq dc5850 Business PCs, and other supported RAID configurations. Mirroring is 100% duplication of AHCI and RAID Technology Definitions Table 1 Basic AHCI and RAID Definitions AHCI ATA BIOS Chipset HDD IDE Advanced Host Controller Interface, a...Electronics. 2 This white paper provides a basic overview of RAID technology, supported factory configurations of RAID into AMD's RS780 and SB700 chipsets. RAID systems may have RAID controllers. Term used to define a collection of Independent Disks) is used with servers, desktop PCs are...