Microsoft Windows 2000 Installation Guide for HP Servers
Page 47
...connector available on drive card cage.) 2. (?) HP D5989A SCSI\processor... 3. (?) HP D5989B SCSI\processor... NetServer LH3, LH4 (!) Intel 82371 AB/EB PCI to USB Universal Controller. (USB chipset is disabled. Action to fix this error: Load the HP Navigator CD-ROM, go to replace integrated ....) Table #6 This table provides a list of NetServers tested with Windows 2000. NetServer LH, LH Pro, LD, LD Pro (!) Trident video controller. (No Driver available. Need to the library diskette section and create the INF driver diskette for the Storage cabinet. Device manager shows ...
...connector available on drive card cage.) 2. (?) HP D5989A SCSI\processor... 3. (?) HP D5989B SCSI\processor... NetServer LH3, LH4 (!) Intel 82371 AB/EB PCI to USB Universal Controller. (USB chipset is disabled. Action to fix this error: Load the HP Navigator CD-ROM, go to replace integrated ....) Table #6 This table provides a list of NetServers tested with Windows 2000. NetServer LH, LH Pro, LD, LD Pro (!) Trident video controller. (No Driver available. Need to the library diskette section and create the INF driver diskette for the Storage cabinet. Device manager shows ...
How to perform unattended NOS installation Using HP Toptools Remote Control
Page 7
...*MUST* be called : Sp4i386.exe) • Create the subfolder SRVTYPE within a sub-folder named lhx as in the following example (LH3 and LH4): \NT4SRV\SRVTYPE\lhx \NT4SRV\SRVTYPE\lhx\cirrus.inf -> LHx video adapter \NT4SRV\SRVTYPE\lhx\cl54xx.dll -> LHx video adapter \NT4SRV\SRVTYPE\lhx\cl54xx... = PCAnywhere source install) • To complete the preparation, you must locate the drivers of the HP Netserver you must enter the name of the server that will have to find the drivers of your HP Netserver to this line: ECHO SET NETSHARE=W2KSRV>> A:\VARS.BAT For NT4, you will contain...
...*MUST* be called : Sp4i386.exe) • Create the subfolder SRVTYPE within a sub-folder named lhx as in the following example (LH3 and LH4): \NT4SRV\SRVTYPE\lhx \NT4SRV\SRVTYPE\lhx\cirrus.inf -> LHx video adapter \NT4SRV\SRVTYPE\lhx\cl54xx.dll -> LHx video adapter \NT4SRV\SRVTYPE\lhx\cl54xx... = PCAnywhere source install) • To complete the preparation, you must locate the drivers of the HP Netserver you must enter the name of the server that will have to find the drivers of your HP Netserver to this line: ECHO SET NETSHARE=W2KSRV>> A:\VARS.BAT For NT4, you will contain...
HP Netserver LC 3 NetRAID Installation Guide
Page 20
...pressing Ctrl+C at this time. If you want to search for a Network Adapter, load NIC drivers for both shared and local storage go to load the correct intra-cluster LAN driver version as specified in the Configuration Guide for shared storage. 5. It must be on page 16... displays the Navigator Main menu. Make sure you need; otherwise allow the server to reboot the server. 2. HP NetServer Installation Guide 14 Select User Preferences and then the LH4 Integrated NetRAID setting you are using NetRAID, AutoRAID Model 12H, and Model 30/FC shared storage solutions. Select ...
...pressing Ctrl+C at this time. If you want to search for a Network Adapter, load NIC drivers for both shared and local storage go to load the correct intra-cluster LAN driver version as specified in the Configuration Guide for shared storage. 5. It must be on page 16... displays the Navigator Main menu. Make sure you need; otherwise allow the server to reboot the server. 2. HP NetServer Installation Guide 14 Select User Preferences and then the LH4 Integrated NetRAID setting you are using NetRAID, AutoRAID Model 12H, and Model 30/FC shared storage solutions. Select ...
HP Netserver LC 3 NetRAID Installation Guide
Page 24
...NIC. • Make sure TCP/IP Protocol is complete, the D5013A NIC drivers must be disabled otherwise it will be the LAN adapter for shared storage, disable the LHI Integrated HP NetRAID. Configure NetServer Hardware and BIOS 1. To update the BIOS, choose Configuration Assistant and Installation ...instructions for both the intra-cluster and the client LAN. Select User Preferences and then the LH4 Integrated NetRAID setting you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and once for your cluster. The server boots from...
...NIC. • Make sure TCP/IP Protocol is complete, the D5013A NIC drivers must be disabled otherwise it will be the LAN adapter for shared storage, disable the LHI Integrated HP NetRAID. Configure NetServer Hardware and BIOS 1. To update the BIOS, choose Configuration Assistant and Installation ...instructions for both the intra-cluster and the client LAN. Select User Preferences and then the LH4 Integrated NetRAID setting you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and once for your cluster. The server boots from...
HP Netserver LC 3 NetRAID-3Si Installation Guide
Page 30
... [1] and specify its IP address and subnet mask. NOTE If prompted that the HP NetServer Navigator BIOS is highlighted and specify its IP address and subnet mask. Be sure to load the correct intra-cluster LAN driver version as specified in the CD-ROM drive and restart the server. 3. Select ...User Preferences and then the LH4 Integrated NetRAID setting you power down System A and power up System B. 2. To update the...
... [1] and specify its IP address and subnet mask. NOTE If prompted that the HP NetServer Navigator BIOS is highlighted and specify its IP address and subnet mask. Be sure to load the correct intra-cluster LAN driver version as specified in the CD-ROM drive and restart the server. 3. Select ...User Preferences and then the LH4 Integrated NetRAID setting you power down System A and power up System B. 2. To update the...
HP Netserver LC 3 NetRAID-3Si Installation Guide
Page 32
...the LAN adapter for DNS, WINS Address, etc. Configure NetServer Hardware and BIOS 1. Select User Preferences and then the LH4 Integrated NetRAID setting you want to the Navigator main menu...the options you need; LH 4 (Fibre Channel) These procedures provide instructions for servers using two HP D5013A NICs, when prompted for TCP/IP Properties: Make sure adapter [2] is highlighted and specify... Once the NT installation is complete, the D5013A NIC drivers must be powered on different subnets. 4. If you have special NetServer local SCSI bus options enter the Symbios utility, by choosing...
...the LAN adapter for DNS, WINS Address, etc. Configure NetServer Hardware and BIOS 1. Select User Preferences and then the LH4 Integrated NetRAID setting you want to the Navigator main menu...the options you need; LH 4 (Fibre Channel) These procedures provide instructions for servers using two HP D5013A NICs, when prompted for TCP/IP Properties: Make sure adapter [2] is highlighted and specify... Once the NT installation is complete, the D5013A NIC drivers must be powered on different subnets. 4. If you have special NetServer local SCSI bus options enter the Symbios utility, by choosing...
HP Netserver LC 3 NetRAID-3Si Installation Guide
Page 40
...Ctrl+C at this time. This will be manually set to 100 Mbps. Insert the HP NetServer Navigator CD in addition, but TCP/IP is required. • If you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and once for your cluster. The server... at the Symbios boot banner during reboot and set the network speed to use the Auto setting. HP NetServer Installation Guide 30 Be sure to step 6; Select User Preferences and then the LH4 Integrated NetRAID setting you need; The server reboots. To update the BIOS, choose Configuration Assistant and ...
...Ctrl+C at this time. This will be manually set to 100 Mbps. Insert the HP NetServer Navigator CD in addition, but TCP/IP is required. • If you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and once for your cluster. The server... at the Symbios boot banner during reboot and set the network speed to use the Auto setting. HP NetServer Installation Guide 30 Be sure to step 6; Select User Preferences and then the LH4 Integrated NetRAID setting you need; The server reboots. To update the BIOS, choose Configuration Assistant and ...
HP Netserver LC 3 NetRAID-3Si Installation Guide
Page 43
..., and Adapters. Select User Preferences and then the LH4 Integrated NetRAID setting you created from the Navigator CD. • First, load the driver for the client LAN. It will normally be the embedded SCSI Symbios driver. • Secondly, load the IDE driver, since the CD drive is complete, the D5013A/B... or 100 Mbps) for both be manually set the network speed to search for a Network Adapter, load NIC drivers for your cluster. at this time. Insert the HP NetServer Navigator CD in the LXr 8000 internal bays this will be the LAN adapter for the device you need. For...
..., and Adapters. Select User Preferences and then the LH4 Integrated NetRAID setting you created from the Navigator CD. • First, load the driver for the client LAN. It will normally be the embedded SCSI Symbios driver. • Secondly, load the IDE driver, since the CD drive is complete, the D5013A/B... or 100 Mbps) for both be manually set the network speed to search for a Network Adapter, load NIC drivers for your cluster. at this time. Insert the HP NetServer Navigator CD in the LXr 8000 internal bays this will be the LAN adapter for the device you need. For...
HP Netserver LCII NetRAID Installation Guide
Page 20
... for automated NOS installation. 7. otherwise go to load the correct intra-cluster LAN driver version as specified in the CD-ROM drive and restart the server. 3. Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server, Enterprise Edition...LH4 Integrated NetRAID setting you power down System A and power up System B. 2. Install Windows NT 1. Select the following options when prompted: • Choose the unpartitioned space and install Windows NT. • Choose NTFS file system • When prompted to search for a Network Adapter, load NIC drivers...
... for automated NOS installation. 7. otherwise go to load the correct intra-cluster LAN driver version as specified in the CD-ROM drive and restart the server. 3. Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server, Enterprise Edition...LH4 Integrated NetRAID setting you power down System A and power up System B. 2. Install Windows NT 1. Select the following options when prompted: • Choose the unpartitioned space and install Windows NT. • Choose NTFS file system • When prompted to search for a Network Adapter, load NIC drivers...
HP Netserver LCII NetRAID Installation Guide
Page 24
... its IP address and subnet mask. Log on different subnets. 5. Select User Preferences and then the LH4 Integrated NetRAID setting you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and once for both the intra-cluster and the client LAN... 30/FC shared storage solutions. • When prompted to step 9. 6. Other protocols may be manually set the network speed to reboot. Configure NetServer Hardware and BIOS 1. otherwise go to 100 Mbps. Select adapter [1] and specify its IP address and subnet mask. LH 4 These procedures provide instructions...
... its IP address and subnet mask. Log on different subnets. 5. Select User Preferences and then the LH4 Integrated NetRAID setting you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and once for both the intra-cluster and the client LAN... 30/FC shared storage solutions. • When prompted to step 9. 6. Other protocols may be manually set the network speed to reboot. Configure NetServer Hardware and BIOS 1. otherwise go to 100 Mbps. Select adapter [1] and specify its IP address and subnet mask. LH 4 These procedures provide instructions...
HP Netserver LH 3 30/FC Installation Guide
Page 24
... for DNS, WINS Address, etc. Configure NetServer Hardware and BIOS 1. Select User Preferences and then the LH4 Integrated NetRAID setting you want to use NetRAID adapters for shared storage. 5. If you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and...and the client LAN. Follow screen prompts to load the correct intra-cluster LAN driver version as specified in the CD-ROM drive and restart the server. 3. HP NetServer Installation Guide 14 Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server, Enterprise ...
... for DNS, WINS Address, etc. Configure NetServer Hardware and BIOS 1. Select User Preferences and then the LH4 Integrated NetRAID setting you want to use NetRAID adapters for shared storage. 5. If you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and...and the client LAN. Follow screen prompts to load the correct intra-cluster LAN driver version as specified in the CD-ROM drive and restart the server. 3. HP NetServer Installation Guide 14 Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server, Enterprise ...
HP Netserver LH 3 30/FC Installation Guide
Page 28
...No for DNS, WINS Address, etc. Log on different subnets. 5. Do not use . Insert the HP NetServer Navigator CD in the Configuration Guide for shared storage. 5. Select User Preferences and then the LH4 Integrated NetRAID setting you need; Exit the Setup Utility (F10, Save, and Exit). Select adapter [1]...menu select: Settings, Control Panel, Network, and Adapters. otherwise go to step 6; Be sure to load the correct intra-cluster LAN driver version as specified in the CD-ROM drive and restart the server. 3. Set TCP/IP Properties for automated NOS installation. NOTE The Client...
...No for DNS, WINS Address, etc. Log on different subnets. 5. Do not use . Insert the HP NetServer Navigator CD in the Configuration Guide for shared storage. 5. Select User Preferences and then the LH4 Integrated NetRAID setting you need; Exit the Setup Utility (F10, Save, and Exit). Select adapter [1]...menu select: Settings, Control Panel, Network, and Adapters. otherwise go to step 6; Be sure to load the correct intra-cluster LAN driver version as specified in the CD-ROM drive and restart the server. 3. Set TCP/IP Properties for automated NOS installation. NOTE The Client...
HP Netserver LH 4 FC Config Guide for Windows 2000 Advanced Server Clusters
Page 2
... than 2 L.18.02 or later Microsoft Windows 2000 Advanced Server HP NetServer LH4 500, 550, 700 MHz 2 - 4 4.06.22 PS or later (500, 550 MHz) 4.06.32 PS or later (700 MHz) Any size 256 MB minimum. Client LAN - Local storage (NetRAID-1Si) Booted from Windows...HP Rack Storage/12FC Host Bus Adapter Model No. of CPUs BIOS version CPU cache RAM No. FC HBA P3 - of HBAs Driver RAID level Required - Shared storage - D5013B P7 - System software: Navigator version Operating System SPU Model Clock speed No. HP D8602A 1 Hhba5100.sys 2.06 0, 1, 3, 5 Cabinet RAID arrays HP NetServer...
... than 2 L.18.02 or later Microsoft Windows 2000 Advanced Server HP NetServer LH4 500, 550, 700 MHz 2 - 4 4.06.22 PS or later (500, 550 MHz) 4.06.32 PS or later (700 MHz) Any size 256 MB minimum. Client LAN - Local storage (NetRAID-1Si) Booted from Windows...HP Rack Storage/12FC Host Bus Adapter Model No. of CPUs BIOS version CPU cache RAM No. FC HBA P3 - of HBAs Driver RAID level Required - Shared storage - D5013B P7 - System software: Navigator version Operating System SPU Model Clock speed No. HP D8602A 1 Hhba5100.sys 2.06 0, 1, 3, 5 Cabinet RAID arrays HP NetServer...
HP Netserver LH 4 FC Config Guide for Windows 2000 Advanced Server Clusters
Page 4
... Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of NICs Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent The intra-cluster LAN may not be used for clusters using the HP NetServer LH4, one required HP Rack Storage/12FC and one or two...
... Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of NICs Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent The intra-cluster LAN may not be used for clusters using the HP NetServer LH4, one required HP Rack Storage/12FC and one or two...
HP Netserver LH 4 FC Windows 2000 Config Guide for Windows 2000 Advanced Server Clusters
Page 2
... Host Bus Adapter Model No. of CPUs BIOS version CPU cache RAM No. System software: Navigator version Operating System SPU Model Clock speed No. P3 - Client LAN P4 - May not use NetRAID-1Si in total. 1 HP Fibre Channel Array Controller - HP D8602A 1 Hhba5100.sys 2.06 P8 0, 1, 3, 5 Not ...cluster (Heartbeat) LANs P7 - of HBAs Driver SPU I /O slots: L.18.02 or later Microsoft Windows 2000 Advanced Server HP NetServer LH4 550, 700 MHz 2 - 4 4.06.22 PS or later (550 MHz) 4.06.32 PS or later (700 MHz) Any size 256 MB minimum. Any HP cables that meet SCSI specifications and any other...
... Host Bus Adapter Model No. of CPUs BIOS version CPU cache RAM No. System software: Navigator version Operating System SPU Model Clock speed No. P3 - Client LAN P4 - May not use NetRAID-1Si in total. 1 HP Fibre Channel Array Controller - HP D8602A 1 Hhba5100.sys 2.06 P8 0, 1, 3, 5 Not ...cluster (Heartbeat) LANs P7 - of HBAs Driver SPU I /O slots: L.18.02 or later Microsoft Windows 2000 Advanced Server HP NetServer LH4 550, 700 MHz 2 - 4 4.06.22 PS or later (550 MHz) 4.06.32 PS or later (700 MHz) Any size 256 MB minimum. Any HP cables that meet SCSI specifications and any other...
HP Netserver LH 4 FC Windows 2000 Config Guide for Windows 2000 Advanced Server Clusters
Page 4
... the Client and Intracluster LANs are supported 4 NIC: Model Driver No. of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH4, one required HP Rack Storage/12FC and one or two optional HP Rack Storage/12s. Only this cabling configuration and these cables are... the same model(D5013A/B), the Client LAN must use the same driver as the Intra-cluster LAN. 1...
... the Client and Intracluster LANs are supported 4 NIC: Model Driver No. of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH4, one required HP Rack Storage/12FC and one or two optional HP Rack Storage/12s. Only this cabling configuration and these cables are... the same model(D5013A/B), the Client LAN must use the same driver as the Intra-cluster LAN. 1...
HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide for Windows NT4.0 Clusters
Page 2
...Drivers Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May use mraidnt.sys version 2.24. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition SP6a or later HP NetServer LH4... 400, 450, 500, 550, 700 MHz 2 - 4 4.06.22 PS or later (400 - 550 MHz) 4.06.32 PS or later (700 MHz) Any size 128 MB... drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any SCSI bus speed. of CPUs BIOS version CPU cache RAM No. Shared storage...
...Drivers Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May use mraidnt.sys version 2.24. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition SP6a or later HP NetServer LH4... 400, 450, 500, 550, 700 MHz 2 - 4 4.06.22 PS or later (400 - 550 MHz) 4.06.32 PS or later (700 MHz) Any size 128 MB... drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any SCSI bus speed. of CPUs BIOS version CPU cache RAM No. Shared storage...
HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide for Windows NT4.0 Clusters
Page 4
...supported. 4 Only these cabling configurations and cables are the same model (D5013A/B) the Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of NICs HP D5013A/B (10/100TX PCI) 3.27.00.0001 or later 1 Any that is on both the... HP Tested Products List and the Microsoft Hardware Compatibility List. NIC: Model Driver No. of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH4, one HP Rack Storage/12FC ...
...supported. 4 Only these cabling configurations and cables are the same model (D5013A/B) the Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of NICs HP D5013A/B (10/100TX PCI) 3.27.00.0001 or later 1 Any that is on both the... HP Tested Products List and the Microsoft Hardware Compatibility List. NIC: Model Driver No. of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH4, one HP Rack Storage/12FC ...
HP Netserver LH 4 Rack Storage/12FC Installation Guide
Page 6
... 256 MB minimum. Must be HP. Host Bus Adapter P2 - Client LAN P4 - Must be HP. 3 required, 4 for redundancy See Local Storage below. of power supplies Local storage I/O slots: Storage HP NetServer LH4 400, 450, 500, 550 MHz. of cabinets FC Array Cards Model No. P1 - Any Shared HP ...RAM No. Simplex (Supplied with Rack Storage/12FC.) 2 - SPU Model Clock speed No. Intra-cluster (Heartbeat) LANs Local Controller Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May Use - Duplex (Additional card required in any manufacturer or driver...
... 256 MB minimum. Must be HP. Host Bus Adapter P2 - Client LAN P4 - Must be HP. 3 required, 4 for redundancy See Local Storage below. of power supplies Local storage I/O slots: Storage HP NetServer LH4 400, 450, 500, 550 MHz. of cabinets FC Array Cards Model No. P1 - Any Shared HP ...RAM No. Simplex (Supplied with Rack Storage/12FC.) 2 - SPU Model Clock speed No. Intra-cluster (Heartbeat) LANs Local Controller Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May Use - Duplex (Additional card required in any manufacturer or driver...
HP Netserver LH 4 with XP256 Cluster Config Guide for Windows NT4.0 Clusters
Page 2
... HP NetServer LH4 400, 450, 500, or 550 MHz 2 - 4 4.06.23PS or later Any size 256 MB minimum. of HBAs/Server Firmware BIOS Driver SPU I/O slot SCSI ID Registry Changes SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Client LAN P5 - of CPUs BIOS version CPU cache RAM ...No. P3 Shared storage controller P1 - com/io/hhba5101.html P3 - May not use embedded SCSI or NetRAID-3Si in cards. Must be HP. 3 See Local Storage below. of power supplies Local storage I /O...
... HP NetServer LH4 400, 450, 500, or 550 MHz 2 - 4 4.06.23PS or later Any size 256 MB minimum. of HBAs/Server Firmware BIOS Driver SPU I/O slot SCSI ID Registry Changes SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Client LAN P5 - of CPUs BIOS version CPU cache RAM ...No. P3 Shared storage controller P1 - com/io/hhba5101.html P3 - May not use embedded SCSI or NetRAID-3Si in cards. Must be HP. 3 See Local Storage below. of power supplies Local storage I /O...