HP Netserver Mass Storage Upgrade Guide
Page 5
HP NetServer LH 3000 & LH 6000 Pedestal Configuration HP NetServer LH 3000r & LH 6000r Rack-mount Configuration Figure 1-1. Refer to install a duplex board on the second hot-swap mass storage cage, do so before you install the cage. The HP NetServer LH 3000 and the HP NetServer LH 6000 are the floor-standing pedestal configurations, and the HP NetServer LH 3000r and the HP NetServer LH 6000r are the rack-optimized configurations, as...
HP NetServer LH 3000 & LH 6000 Pedestal Configuration HP NetServer LH 3000r & LH 6000r Rack-mount Configuration Figure 1-1. Refer to install a duplex board on the second hot-swap mass storage cage, do so before you install the cage. The HP NetServer LH 3000 and the HP NetServer LH 6000 are the floor-standing pedestal configurations, and the HP NetServer LH 3000r and the HP NetServer LH 6000r are the rack-optimized configurations, as...
HP Netserver Mass Storage Upgrade Guide
Page 8
... Figure 1-3 • Screws to mount the hot-swap mass storage cage • SCSI cable to connect the hot-swap mass storage cage • HP NetServer LH 3000/3000r and LH 6000/6000r Mass Storage Upgrade Guide (this document) If anything is missing or damaged, contact your reseller. 4 Front and Rear Views of Hot-Swap Mass...
... Figure 1-3 • Screws to mount the hot-swap mass storage cage • SCSI cable to connect the hot-swap mass storage cage • HP NetServer LH 3000/3000r and LH 6000/6000r Mass Storage Upgrade Guide (this document) If anything is missing or damaged, contact your reseller. 4 Front and Rear Views of Hot-Swap Mass...
HP Netserver Mass Storage Upgrade Guide
Page 9
... Documentation CD-ROM contains all of the documents listed above. 5 The HP NetServer Duplex Board Installation Guide is supplied with the kit used for your HP NetServer: • HP NetServer LH 3000/3000r Installation Guide • HP NetServer LH 6000/6000r Installation Guide • Integrated HP NetRAID Controller Configuration Guide The HP NetServer Ultra2 SCSI Hot-swap Hard Disk Drive and Tray User Guide...
... Documentation CD-ROM contains all of the documents listed above. 5 The HP NetServer Duplex Board Installation Guide is supplied with the kit used for your HP NetServer: • HP NetServer LH 3000/3000r Installation Guide • HP NetServer LH 6000/6000r Installation Guide • Integrated HP NetRAID Controller Configuration Guide The HP NetServer Ultra2 SCSI Hot-swap Hard Disk Drive and Tray User Guide...
HP Netserver Mass Storage Upgrade Guide
Page 12
.... Also lower the leveler feet of the rack to improve stability and to your HP NetServer installation guide for your HP NetServer configuration: • HP NetServer LH 3000/3000r Installation Guide • HP NetServer LH 6000/6000r Installation Guide • The Installation Guide for Compaq® 4000/7000 Racks ...feet could result in a rack, extend the anti-tip foot or attach the anti-tip feature before extending the HP NetServer from the HP NetServer. Chapter 2 Installation 3. WARNING Before removing the cover, always disconnect the power cord(s) and unplug telephone cables. ...
.... Also lower the leveler feet of the rack to improve stability and to your HP NetServer installation guide for your HP NetServer configuration: • HP NetServer LH 3000/3000r Installation Guide • HP NetServer LH 6000/6000r Installation Guide • The Installation Guide for Compaq® 4000/7000 Racks ...feet could result in a rack, extend the anti-tip foot or attach the anti-tip feature before extending the HP NetServer from the HP NetServer. Chapter 2 Installation 3. WARNING Before removing the cover, always disconnect the power cord(s) and unplug telephone cables. ...
HP Netserver Mass Storage Upgrade Guide
Page 15
Chapter 2 Installation 4. Insert and Tighten Two Screws (1), and Then Insert and Tighten Six Screws (2) 5. Figure 2-3. Insert six screws into the front of the chassis. Using the two circular access holes in the chassis shown in Figure 2-3, insert and tighten two screws supplied with the upgrade kit. ◊ HP NetServer LH 3000 and LH 6000 access holes are on the side of the chassis. ◊ HP NetServer LH 3000r and LH 6000r access holes are on the top of the hot-swap mass storage cage, as shown in Figure 2-3, and tighten them. 11
Chapter 2 Installation 4. Insert and Tighten Two Screws (1), and Then Insert and Tighten Six Screws (2) 5. Figure 2-3. Insert six screws into the front of the chassis. Using the two circular access holes in the chassis shown in Figure 2-3, insert and tighten two screws supplied with the upgrade kit. ◊ HP NetServer LH 3000 and LH 6000 access holes are on the side of the chassis. ◊ HP NetServer LH 3000r and LH 6000r access holes are on the top of the hot-swap mass storage cage, as shown in Figure 2-3, and tighten them. 11
HP Netserver Mass Storage Upgrade Guide
Page 39
... still displayed. To change to non-RAID mode, refer to start Symbios Configuration Utility... Some power-up (boot) messages are operating in the HP NetServer LH 3000/3000r or LH 6000/6000r Installation Guide(s) or the online help. Chapter 3 Configure Mass Storage Run Symbios Configuration Utility NOTE Run the Symbios Configuration utility to do the...
... still displayed. To change to non-RAID mode, refer to start Symbios Configuration Utility... Some power-up (boot) messages are operating in the HP NetServer LH 3000/3000r or LH 6000/6000r Installation Guide(s) or the online help. Chapter 3 Configure Mass Storage Run Symbios Configuration Utility NOTE Run the Symbios Configuration utility to do the...
HP Netserver Mass Storage Upgrade Guide
Page 47
..., 32 Configuring mass storage, 29 non-RAID, 30 RAID, 30 Contents of kit, 4 Cover plate, 9 D Default settings, 34 Disconnecting the HP NetServer, 7 Disk drives configuring, 29 verifying, 37 Documents, 5 Drive spacers, 24 E Embedded LAN and SCSI Settings, 34 Environmental specifications, 41 Error ..., 20 Hot-swap mass storage cage configuring, 29 features, 4 installing, 7, 10 verifying, 38 HP NetRAID Express Tools, 32 Clear Configuration, 32 Configure menu, 32 Management Menu, 32 Ultra2 SCSI, 30 HP NetServer LH 3000, 1 HP NetServer LH 3000r, 1 HP NetServer LH 6000, 1 HP NetServer LH 6000r, 1 43
..., 32 Configuring mass storage, 29 non-RAID, 30 RAID, 30 Contents of kit, 4 Cover plate, 9 D Default settings, 34 Disconnecting the HP NetServer, 7 Disk drives configuring, 29 verifying, 37 Documents, 5 Drive spacers, 24 E Embedded LAN and SCSI Settings, 34 Environmental specifications, 41 Error ..., 20 Hot-swap mass storage cage configuring, 29 features, 4 installing, 7, 10 verifying, 38 HP NetRAID Express Tools, 32 Clear Configuration, 32 Configure menu, 32 Management Menu, 32 Ultra2 SCSI, 30 HP NetServer LH 3000, 1 HP NetServer LH 3000r, 1 HP NetServer LH 6000, 1 HP NetServer LH 6000r, 1 43
HP Netserver Ultra3 SCSI HBA Guide
Page 12
..., LH 3000/6000) LVD hot-swap Cage Internal Use existing twisted-pair cable in Netserver * The P3469A Cable Kit contains both Terminated and Point-to VHDC1, 2.5m All Models HP SureStore DLT80e/80k & DAT 40e/40k External C5666A - HDTS68 to HDTS68, 0.9m C5667A - Netserver SCSI Cables HP Netserver SCSI Devices Interface Cable Product Number All Models HP Netserver Rack...
..., LH 3000/6000) LVD hot-swap Cage Internal Use existing twisted-pair cable in Netserver * The P3469A Cable Kit contains both Terminated and Point-to VHDC1, 2.5m All Models HP SureStore DLT80e/80k & DAT 40e/40k External C5666A - HDTS68 to HDTS68, 0.9m C5667A - Netserver SCSI Cables HP Netserver SCSI Devices Interface Cable Product Number All Models HP Netserver Rack...
Installing SCO UNIX on an HP Netserver
Page 5
...driver after the system is up and running . This is the safest choice. Configuring a Mouse All HP NetServers have a PS/2 style mouse. Configuring Video for UNIX When configuring the video for UNIX, standard VGA ... as a mini-DIN or keyboard mouse. If you place in the HP NetServers: E 30: S3 Trio 64V+, 1MB or 2MB video memory E 40, LC II, LC 3, LH 3, LH 4, LPr, LXr 8000: Cirrus Logic CL-GD5446, 1MB or 2MB video...LX Pro, LXe Pro, LXr Pro: Cirrus Logic CL-GD5424, 512KB or 1MB video memory LC 2000, LH 3000 LH 6000, LT 6000r: ATI Rage II c on board card, 2MB video memory E 800: ATI Rage XL ...
...driver after the system is up and running . This is the safest choice. Configuring a Mouse All HP NetServers have a PS/2 style mouse. Configuring Video for UNIX When configuring the video for UNIX, standard VGA ... as a mini-DIN or keyboard mouse. If you place in the HP NetServers: E 30: S3 Trio 64V+, 1MB or 2MB video memory E 40, LC II, LC 3, LH 3, LH 4, LPr, LXr 8000: Cirrus Logic CL-GD5446, 1MB or 2MB video...LX Pro, LXe Pro, LXr Pro: Cirrus Logic CL-GD5424, 512KB or 1MB video memory LC 2000, LH 3000 LH 6000, LT 6000r: ATI Rage II c on board card, 2MB video memory E 800: ATI Rage XL ...
Installing SCO UNIX on an HP Netserver
Page 7
... AIC7870 alad325 LH 6000 Symbios 895 slha LH 6000 AIC7870 alad325 LT 6000r Symbios 895 slha LS AIC7870 alad or alad325 LX, LXe, LXr Pro AIC7880 alad or alad325 LXr 8000 Symbios 53C896 slha All HP Disk Array mdac All HP NetRAID amird NOTE: HP currently does not support ...drive. The root hard disk must be SCSI ID 2. OpenServer 5.0.5 has a bootable CD-ROM for disks installed in the HP NetServer cabinet and in the HP NetServer Rack Storage System 8 and 12. Ultra SCSI mode is especially important if you have a complicated hardware configuration, install SCO OpenServer...
... AIC7870 alad325 LH 6000 Symbios 895 slha LH 6000 AIC7870 alad325 LT 6000r Symbios 895 slha LS AIC7870 alad or alad325 LX, LXe, LXr Pro AIC7880 alad or alad325 LXr 8000 Symbios 53C896 slha All HP Disk Array mdac All HP NetRAID amird NOTE: HP currently does not support ...drive. The root hard disk must be SCSI ID 2. OpenServer 5.0.5 has a bootable CD-ROM for disks installed in the HP NetServer cabinet and in the HP NetServer Rack Storage System 8 and 12. Ultra SCSI mode is especially important if you have a complicated hardware configuration, install SCO OpenServer...
Installing SCO UnixWare on an HP Netserver
Page 5
... LH3,LH4, Symbios895 c8xx NetRaid 3Si mega LC 2000 Symbios895 slha & mega LH 3000 Symbios896 slha & mega LH 6000 Symbios896 slha & mega LT 6000r Symbios896 slha & mega NOTE: HP currently does not support ultra SCSI mode on the primary SCSI channel. The... root hard disk must be SCSI ID 0. The first SCSI CD-ROM drive must be SCSI ID 5. Troubleshooting SCO UnixWare is supported for disks installed in the HP NetServer...
... LH3,LH4, Symbios895 c8xx NetRaid 3Si mega LC 2000 Symbios895 slha & mega LH 3000 Symbios896 slha & mega LH 6000 Symbios896 slha & mega LT 6000r Symbios896 slha & mega NOTE: HP currently does not support ultra SCSI mode on the primary SCSI channel. The... root hard disk must be SCSI ID 0. The first SCSI CD-ROM drive must be SCSI ID 5. Troubleshooting SCO UnixWare is supported for disks installed in the HP NetServer...