HP Netserver Mass Storage Upgrade Guide
Page 5
... Kit Installation Guide for installing an accessory second hot-swap mass storage cage into your HP NetServer LH 3000 or LH 3000r, or your LH 6000 or LH 6000r. The HP NetServer LH 3000 and the HP NetServer LH 6000 are the floor-standing pedestal configurations, and the HP NetServer LH 3000r and the HP NetServer LH 6000r are the rack-optimized configurations, as shown in Figure 1-1. Refer to install a duplex board...
... Kit Installation Guide for installing an accessory second hot-swap mass storage cage into your HP NetServer LH 3000 or LH 3000r, or your LH 6000 or LH 6000r. The HP NetServer LH 3000 and the HP NetServer LH 6000 are the floor-standing pedestal configurations, and the HP NetServer LH 3000r and the HP NetServer LH 6000r are the rack-optimized configurations, as shown in Figure 1-1. Refer to install a duplex board...
HP Netserver Mass Storage Upgrade Guide
Page 8
... side. Chapter 1 Introduction Verify Contents CAUTION An insulating sheet shown in place, and be careful not to connect the hot-swap mass storage cage • HP NetServer LH 3000/3000r and LH 6000/6000r Mass Storage Upgrade Guide (this document) If anything is missing or damaged, contact your reseller. 4
... side. Chapter 1 Introduction Verify Contents CAUTION An insulating sheet shown in place, and be careful not to connect the hot-swap mass storage cage • HP NetServer LH 3000/3000r and LH 6000/6000r Mass Storage Upgrade Guide (this document) If anything is missing or damaged, contact your reseller. 4
HP Netserver Mass Storage Upgrade Guide
Page 9
...to the Installation Guide for Compaq® 4000/7000 Racks for your HP NetServer: • HP NetServer LH 3000/3000r Installation Guide • HP NetServer LH 6000/6000r Installation Guide • Integrated HP NetRAID Controller Configuration Guide The HP NetServer Ultra2 SCSI Hot-swap Hard Disk Drive and Tray User Guide is...8226; T25 Torx driver (required for systems mounted in a Compaq rack, refer to install a duplex board. The HP NetServer Online Documentation CD-ROM contains all of the documents listed above. 5 Chapter 1 Introduction Tools You Need The following documents supplied with...
...to the Installation Guide for Compaq® 4000/7000 Racks for your HP NetServer: • HP NetServer LH 3000/3000r Installation Guide • HP NetServer LH 6000/6000r Installation Guide • Integrated HP NetRAID Controller Configuration Guide The HP NetServer Ultra2 SCSI Hot-swap Hard Disk Drive and Tray User Guide is...8226; T25 Torx driver (required for systems mounted in a Compaq rack, refer to install a duplex board. The HP NetServer Online Documentation CD-ROM contains all of the documents listed above. 5 Chapter 1 Introduction Tools You Need The following documents supplied with...
HP Netserver Mass Storage Upgrade Guide
Page 12
...the backlight on the front panel LCD is still on, standby power is installed in a rack, extend the HP NetServer from the HP NetServer. Note that apply to high energy levels that may cause burns when parts are short-circuited by metal objects ... turn off the standby power. Turn off standby power. Refer to the HP NetServer. 4. Disconnect the power cord(s) to avoid exposure to your HP NetServer configuration: • HP NetServer LH 3000/3000r Installation Guide • HP NetServer LH 6000/6000r Installation Guide • The Installation Guide for Compaq® 4000/7000 Racks...
...the backlight on the front panel LCD is still on, standby power is installed in a rack, extend the HP NetServer from the HP NetServer. Note that apply to high energy levels that may cause burns when parts are short-circuited by metal objects ... turn off the standby power. Turn off standby power. Refer to the HP NetServer. 4. Disconnect the power cord(s) to avoid exposure to your HP NetServer configuration: • HP NetServer LH 3000/3000r Installation Guide • HP NetServer LH 6000/6000r Installation Guide • The Installation Guide for Compaq® 4000/7000 Racks...
HP Netserver Mass Storage Upgrade Guide
Page 15
Using the two circular access holes in the chassis shown in Figure 2-3, insert and tighten two screws supplied with the upgrade kit. ◊ HP NetServer LH 3000 and LH 6000 access holes are on the side of the chassis. ◊ HP NetServer LH 3000r and LH 6000r access holes are on the top of the hot-swap mass storage cage, as shown in Figure 2-3, and tighten them. 11 Insert six screws into the front of the chassis. Insert and Tighten Two Screws (1), and Then Insert and Tighten Six Screws (2) 5. Figure 2-3. Chapter 2 Installation 4.
Using the two circular access holes in the chassis shown in Figure 2-3, insert and tighten two screws supplied with the upgrade kit. ◊ HP NetServer LH 3000 and LH 6000 access holes are on the side of the chassis. ◊ HP NetServer LH 3000r and LH 6000r access holes are on the top of the hot-swap mass storage cage, as shown in Figure 2-3, and tighten them. 11 Insert six screws into the front of the chassis. Insert and Tighten Two Screws (1), and Then Insert and Tighten Six Screws (2) 5. Figure 2-3. Chapter 2 Installation 4.
HP Netserver Mass Storage Upgrade Guide
Page 39
...bootable drive. • To control the order in which SCSI channels A and B are searched for a bootable drive. If this happens, restart the HP NetServer, and press the Ctrl+C keys as soon as you receive an error message during the boot process, refer to "Run Setup Utility". If you wait...appears. 35 NOTE If SCSI A and B on the I/O baseboard are routine. 2. Some power-up (boot) messages are operating in the HP NetServer LH 3000/3000r or LH 6000/6000r Installation Guide(s) or the online help. To change to non-RAID mode, refer to "Troubleshooting" in RAID mode, the prompt to start ...
...bootable drive. • To control the order in which SCSI channels A and B are searched for a bootable drive. If this happens, restart the HP NetServer, and press the Ctrl+C keys as soon as you receive an error message during the boot process, refer to "Run Setup Utility". If you wait...appears. 35 NOTE If SCSI A and B on the I/O baseboard are routine. 2. Some power-up (boot) messages are operating in the HP NetServer LH 3000/3000r or LH 6000/6000r Installation Guide(s) or the online help. To change to non-RAID mode, refer to "Troubleshooting" in RAID mode, the prompt to start ...
HP Netserver Mass Storage Upgrade Guide
Page 47
..., 32 Configuring mass storage, 29 non-RAID, 30 RAID, 30 Contents of kit, 4 Cover plate, 9 D Default settings, 34 Disconnecting the HP NetServer, 7 Disk drives configuring, 29 verifying, 37 Documents, 5 Drive spacers, 24 E Embedded LAN and SCSI Settings, 34 Environmental specifications, 41 Error ..., 20 Hot-swap mass storage cage configuring, 29 features, 4 installing, 7, 10 verifying, 38 HP NetRAID Express Tools, 32 Clear Configuration, 32 Configure menu, 32 Management Menu, 32 Ultra2 SCSI, 30 HP NetServer LH 3000, 1 HP NetServer LH 3000r, 1 HP NetServer LH 6000, 1 HP NetServer LH 6000r, 1 43
..., 32 Configuring mass storage, 29 non-RAID, 30 RAID, 30 Contents of kit, 4 Cover plate, 9 D Default settings, 34 Disconnecting the HP NetServer, 7 Disk drives configuring, 29 verifying, 37 Documents, 5 Drive spacers, 24 E Embedded LAN and SCSI Settings, 34 Environmental specifications, 41 Error ..., 20 Hot-swap mass storage cage configuring, 29 features, 4 installing, 7, 10 verifying, 38 HP NetRAID Express Tools, 32 Clear Configuration, 32 Configure menu, 32 Management Menu, 32 Ultra2 SCSI, 30 HP NetServer LH 3000, 1 HP NetServer LH 3000r, 1 HP NetServer LH 6000, 1 HP NetServer LH 6000r, 1 43
Installation Guide for Compaq Racks
Page 1
HP NetServer LH 3r, LH 4r, LH 3000r, and LH 6000r Installation Guide for Compaq® 4000/7000 Racks HP Part Number 5969-5924 Printed in November 1999
HP NetServer LH 3r, LH 4r, LH 3000r, and LH 6000r Installation Guide for Compaq® 4000/7000 Racks HP Part Number 5969-5924 Printed in November 1999
Installation Guide for Compaq Racks
Page 3
... 7 Preparation...7 Marking the Installation Holes 7 Installing the Bar Nuts, Screws, and Cage Nuts 9 Mounting the Slides 10 Installing the NetServer 12 Mounting the NetServer to the Slides 12 Optional for HP NetServer LH 3000r and LH 6000r, Install Cable Management Arm 16 Installing the Recessed Mounting Brackets 18 Relocating the Control Panel 19 Installing the Bezel 22...
... 7 Preparation...7 Marking the Installation Holes 7 Installing the Bar Nuts, Screws, and Cage Nuts 9 Mounting the Slides 10 Installing the NetServer 12 Mounting the NetServer to the Slides 12 Optional for HP NetServer LH 3000r and LH 6000r, Install Cable Management Arm 16 Installing the Recessed Mounting Brackets 18 Relocating the Control Panel 19 Installing the Bezel 22...
Installation Guide for Compaq Racks
Page 5
... to convert a pedestal version for installation in a rack enclosure, contact your HP Reseller for instructions on adding accessories to mount an HP NetServer LH 3r, LH 4r, LH3000r, or LH 6000r into a Compaq® model 4000- 1 Introduction This document describes how to , and configuring the NetServer. Pedestal and rack-optimized versions are shown in a rack enclosure. Versions of...
... to convert a pedestal version for installation in a rack enclosure, contact your HP Reseller for instructions on adding accessories to mount an HP NetServer LH 3r, LH 4r, LH3000r, or LH 6000r into a Compaq® model 4000- 1 Introduction This document describes how to , and configuring the NetServer. Pedestal and rack-optimized versions are shown in a rack enclosure. Versions of...
Installation Guide for Compaq Racks
Page 9
detailed instructions are summarized below: NOTE This is only a summary; 2 Overview The steps required to install the NetServer in the rack are provided on the following pages. • Measure and mark the appropriate holes on all four rack columns. ... from the NetServer. • Lift the NetServer onto the slides. • Secure the NetServer to the slides. • Remove the lifting handles from the NetServer. • Reinstall the power supply modules and hot-swap drives. • Push the NetServer back into the rack enclosure. • For HP NetServer LH 3000r and LH 6000r, attach the...
detailed instructions are summarized below: NOTE This is only a summary; 2 Overview The steps required to install the NetServer in the rack are provided on the following pages. • Measure and mark the appropriate holes on all four rack columns. ... from the NetServer. • Lift the NetServer onto the slides. • Secure the NetServer to the slides. • Remove the lifting handles from the NetServer. • Reinstall the power supply modules and hot-swap drives. • Push the NetServer back into the rack enclosure. • For HP NetServer LH 3000r and LH 6000r, attach the...
Installation Guide for Compaq Racks
Page 11
... and top of the NetServer into the rack, you must prepare the rack and the NetServer. To mark the slide mounting holes refer to Figure 3-1: 1. Determine the location at this is the column surface facing forward; 3 Installation This section contains detailed instructions for installing an HP NetServer NetServer LH 3r, LH 4r, LH 3000r, or LH 6000r in the rack...
... and top of the NetServer into the rack, you must prepare the rack and the NetServer. To mark the slide mounting holes refer to Figure 3-1: 1. Determine the location at this is the column surface facing forward; 3 Installation This section contains detailed instructions for installing an HP NetServer NetServer LH 3r, LH 4r, LH 3000r, or LH 6000r in the rack...
Installation Guide for Compaq Racks
Page 16
... weighs approximately 118 pounds (54 kg) after it has been removed. Follow local regulations when lifting the NetServer. Fire or bodily injury may be installed. Before you hear a click, indicating they are removed. The HP NetServer LH 6000r weighs approximately 148 pounds (67 kg) after the hard disk drives and power supply modules are removed...
... weighs approximately 118 pounds (54 kg) after it has been removed. Follow local regulations when lifting the NetServer. Fire or bodily injury may be installed. Before you hear a click, indicating they are removed. The HP NetServer LH 6000r weighs approximately 148 pounds (67 kg) after the hard disk drives and power supply modules are removed...
Installation Guide for Compaq Racks
Page 20
... pushed all the way into the rack. 2. See Figure 3-8. 16 See Figure 3-8. Chapter 3 Installation Optional for HP NetServer LH 3000r and LH 6000r, Install Cable Management Arm The HP NetServer Cable Management Arm supplied with the HP LH 3000r and LH 6000r allows the cables, including the power cord, to move in the 17th and 18th holes above the baseline of...
... pushed all the way into the rack. 2. See Figure 3-8. 16 See Figure 3-8. Chapter 3 Installation Optional for HP NetServer LH 3000r and LH 6000r, Install Cable Management Arm The HP NetServer Cable Management Arm supplied with the HP LH 3000r and LH 6000r allows the cables, including the power cord, to move in the 17th and 18th holes above the baseline of...
Installing SCO UNIX on an HP Netserver
Page 5
...to configure such a mouse as a mini-DIN or keyboard mouse. This is the safest choice. If this is up and running . Configuring a Mouse All HP NetServers have a PS/2 style mouse. A scratch division is the safest choice for specifying mouse type. The following video chips are used in case of the operating...: Trident TVGA9000I, 512KB video memory LS, LX Pro, LXe Pro, LXr Pro: Cirrus Logic CL-GD5424, 512KB or 1MB video memory LC 2000, LH 3000 LH 6000, LT 6000r: ATI Rage II c on board card, 2MB video memory E 800: ATI Rage XL on board card, 4MB video. Driver and install guide can ...
...to configure such a mouse as a mini-DIN or keyboard mouse. This is the safest choice. If this is up and running . Configuring a Mouse All HP NetServers have a PS/2 style mouse. A scratch division is the safest choice for specifying mouse type. The following video chips are used in case of the operating...: Trident TVGA9000I, 512KB video memory LS, LX Pro, LXe Pro, LXr Pro: Cirrus Logic CL-GD5424, 512KB or 1MB video memory LC 2000, LH 3000 LH 6000, LT 6000r: ATI Rage II c on board card, 2MB video memory E 800: ATI Rage XL on board card, 4MB video. Driver and install guide can ...
Installing SCO UNIX on an HP Netserver
Page 7
... SCSI tape drive must be SCSI ID 5, or for installation. Troubleshooting SCO OpenServer is supported for disks installed in the HP NetServer cabinet and in the HP NetServer Rack Storage System 8 and 12. The first SCSI CD-ROM drive must be on the primary SCSI channel. The correct... AIC7870 alad325 LH 6000 Symbios 895 slha LH 6000 AIC7870 alad325 LT 6000r Symbios 895 slha LS AIC7870 alad or alad325 LX, LXe, LXr Pro AIC7880 alad or alad325 LXr 8000 Symbios 53C896 slha All HP Disk Array mdac All HP NetRAID amird NOTE: HP currently does not support ultra SCSI ...
... SCSI tape drive must be SCSI ID 5, or for installation. Troubleshooting SCO OpenServer is supported for disks installed in the HP NetServer cabinet and in the HP NetServer Rack Storage System 8 and 12. The first SCSI CD-ROM drive must be on the primary SCSI channel. The correct... AIC7870 alad325 LH 6000 Symbios 895 slha LH 6000 AIC7870 alad325 LT 6000r Symbios 895 slha LS AIC7870 alad or alad325 LX, LXe, LXr Pro AIC7880 alad or alad325 LXr 8000 Symbios 53C896 slha All HP Disk Array mdac All HP NetRAID amird NOTE: HP currently does not support ultra SCSI ...
Installing SCO UnixWare on an HP Netserver
Page 5
...Symbios895 c8xx LH3,LH4, Symbios895 c8xx NetRaid 3Si mega LC 2000 Symbios895 slha & mega LH 3000 Symbios896 slha & mega LH 6000 Symbios896 slha & mega LT 6000r Symbios896 slha & mega NOTE: HP currently does not support ultra SCSI mode on the primary SCSI channel. The root hard...a complicated hardware configuration, install SCO UnixWare using only the minimum system required to the HP Storage System 6. Troubleshooting SCO UnixWare is supported for disks installed in the HP NetServer cabinet. All additional hardware can be SCSI ID 5. Ultra SCSI mode is very specific...
...Symbios895 c8xx LH3,LH4, Symbios895 c8xx NetRaid 3Si mega LC 2000 Symbios895 slha & mega LH 3000 Symbios896 slha & mega LH 6000 Symbios896 slha & mega LT 6000r Symbios896 slha & mega NOTE: HP currently does not support ultra SCSI mode on the primary SCSI channel. The root hard...a complicated hardware configuration, install SCO UnixWare using only the minimum system required to the HP Storage System 6. Troubleshooting SCO UnixWare is supported for disks installed in the HP NetServer cabinet. All additional hardware can be SCSI ID 5. Ultra SCSI mode is very specific...