HP UPS Best Practices
Page 1
... Model Numbers ...6 UPS Options ...6 HP Rackmount UPS Advantages 6 HP Rackmount UPS Models...8 HP R1500 G2 Rackmount UPS 8 HP R3000 Rackmount UPS ...8 HP R/T3000 Rackmount UPS 9 HP R5500 Rackmount UPS ...10 HP Three-phase Rack-mountable UPS 11 HP Tower UPS Advantages...12 HP Tower UPS Models ...13 HP T750 G2 UPS...13 HP T1000 G3 and T1500 G3 UPSs 13 HP T750 Japan T1000 Japan...
... Model Numbers ...6 UPS Options ...6 HP Rackmount UPS Advantages 6 HP Rackmount UPS Models...8 HP R1500 G2 Rackmount UPS 8 HP R3000 Rackmount UPS ...8 HP R/T3000 Rackmount UPS 9 HP R5500 Rackmount UPS ...10 HP Three-phase Rack-mountable UPS 11 HP Tower UPS Advantages...12 HP Tower UPS Models ...13 HP T750 G2 UPS...13 HP T1000 G3 and T1500 G3 UPSs 13 HP T750 Japan T1000 Japan...
HP UPS Best Practices
Page 6
...HP UPS Models Available Rackmount UPS Model Numbers AF419A R1500 G2 NA AF418A R1500 G2 INTL AF421A R1500 ...G3 NA AF451A T1500 G3 INTL AF458A T1500 JAPAN UPS Options AF402A AF415A AF455A AF417A AF442A AF434A AF436A AF437A Management Module Serial Adapter - 5 pack R3000 ERM R/T3000 ERM R5500 ERM R5500 Tower Conversion Kit R8000/3 and R12000/3 ERM HP R12000/3 EXPANSION MODULE FOR RP36000/3 NA HP... such as industry-leading power density and more true power in a smaller form factor, HP rackmount UPSs deliver maximum uptime with a host of competitive advantages including: Enhanced Battery Management ...
...HP UPS Models Available Rackmount UPS Model Numbers AF419A R1500 G2 NA AF418A R1500 G2 INTL AF421A R1500 ...G3 NA AF451A T1500 G3 INTL AF458A T1500 JAPAN UPS Options AF402A AF415A AF455A AF417A AF442A AF434A AF436A AF437A Management Module Serial Adapter - 5 pack R3000 ERM R/T3000 ERM R5500 ERM R5500 Tower Conversion Kit R8000/3 and R12000/3 ERM HP R12000/3 EXPANSION MODULE FOR RP36000/3 NA HP... such as industry-leading power density and more true power in a smaller form factor, HP rackmount UPSs deliver maximum uptime with a host of competitive advantages including: Enhanced Battery Management ...
HP UPS R1500 G3 Installation Instructions
Page 2
...supply connections other than room ambient temperature. The installation of options and routine maintenance and service of this document, see the HP website (http://www.hp.com/go /rackandpower). After determining the class of the equipment. This document contains important safety instructions that the UPS exceeds ...B) of the device, refer to 1320 VA/1000 W (NA/TWN), 1200 VA/900 W (JPN) or 1500 VA/1000 W (INTL). Overview The HP UPS R1500 G3 features a 1U rack-mount design and offers power protection for loads up to the user guide for complete regulatory compliance notices.
...supply connections other than room ambient temperature. The installation of options and routine maintenance and service of this document, see the HP website (http://www.hp.com/go /rackandpower). After determining the class of the equipment. This document contains important safety instructions that the UPS exceeds ...B) of the device, refer to 1320 VA/1000 W (NA/TWN), 1200 VA/900 W (JPN) or 1500 VA/1000 W (INTL). Overview The HP UPS R1500 G3 features a 1U rack-mount design and offers power protection for loads up to the user guide for complete regulatory compliance notices.
HP UPS R1500 G3 Installation Instructions
Page 5
.... IMPORTANT: Power management software requires the communications port to be connected to the battery terminal. NOTE: A small amount of HP Power Protector. This is normal and does not damage the unit or present any safety concern. Connecting more than one communications port... serial cable included with the UPS to connect the communications port to the desired voltage configuration. Connect the battery lead to the host computer. R1500 G3 JPN/TWN R1500 G3 NA R1500 G3 INTL Output voltage 100 V* 110 V 110 V 120 V* 220 V 230 V* 240 V Input voltage range 90-106 V DIP switch...
.... IMPORTANT: Power management software requires the communications port to be connected to the battery terminal. NOTE: A small amount of HP Power Protector. This is normal and does not damage the unit or present any safety concern. Connecting more than one communications port... serial cable included with the UPS to connect the communications port to the desired voltage configuration. Connect the battery lead to the host computer. R1500 G3 JPN/TWN R1500 G3 NA R1500 G3 INTL Output voltage 100 V* 110 V 110 V 120 V* 220 V 230 V* 240 V Input voltage range 90-106 V DIP switch...
HP UPS Network Module User Guide
Page 7
...be attached in any machine that is a UPS software management application that server and optionally run a script during power failure. HP Power Protector overview HP Power Protector is powered by a UPS and communicates with two UPS Network Modules over the network to begin a graceful shutdown... (on page 7)-One or more information, see the HP Power Protector User Guide on the HP website (http://www.hp.com/go /rackandpower). You can be used standalone without the UPS Network Module in an Administrator/Client configuration or with the R1500 G3 UPS, R/T3000 G2 UPS, R5000 UPS and R7000...
...be attached in any machine that is a UPS software management application that server and optionally run a script during power failure. HP Power Protector overview HP Power Protector is powered by a UPS and communicates with two UPS Network Modules over the network to begin a graceful shutdown... (on page 7)-One or more information, see the HP Power Protector User Guide on the HP website (http://www.hp.com/go /rackandpower). You can be used standalone without the UPS Network Module in an Administrator/Client configuration or with the R1500 G3 UPS, R/T3000 G2 UPS, R5000 UPS and R7000...
HP R1500 G3 UPS User Guide
Page 1
HP assumes you are qualified in the servicing of high-voltage equipment and trained in recognizing hazards in products with hazardous energy levels. Part Number: 651175-002 August 2012 Edition: 2 HP R1500 G3 UPS User Guide Abstract This document includes installation, configuration, and operation information for the person who installs and maintains power products. This document is for the HP R1500 G3 UPS.
HP assumes you are qualified in the servicing of high-voltage equipment and trained in recognizing hazards in products with hazardous energy levels. Part Number: 651175-002 August 2012 Edition: 2 HP R1500 G3 UPS User Guide Abstract This document includes installation, configuration, and operation information for the person who installs and maintains power products. This document is for the HP R1500 G3 UPS.
HP R1500 G3 UPS User Guide
Page 3
... ...6 UPS front panel ...6 UPS front panel controls ...7 UPS front panel LED indicators ...7 UPS R1500 G3 NA/JPN/TWN rear panel 8 UPS R1500 G3 INTL rear panel ...9 Installation ...10 Precautions...10 Preparing to install the hardware...10 Tools required ...10 Selecting a site...10 Readying the equipment ...11 Installing the ...
... ...6 UPS front panel ...6 UPS front panel controls ...7 UPS front panel LED indicators ...7 UPS R1500 G3 NA/JPN/TWN rear panel 8 UPS R1500 G3 INTL rear panel ...9 Installation ...10 Precautions...10 Preparing to install the hardware...10 Tools required ...10 Selecting a site...10 Readying the equipment ...11 Installing the ...
HP R1500 G3 UPS User Guide
Page 6
To benefit from the latest product enhancements, update to 1440 VA/1000 W (NA), 1200 VA/900 W (JPN/TWN) or 1500 VA/1000 W (INTL). NOTE: To download the latest versions of UPS firmware and software. UPS front panel Item 1 2 Description Battery compartment Control buttons and LED display Component identification 6 Component identification UPS R1500 G3 overview The HP UPS R1500 G3 features a 1U rack-mount design and offers power protection for loads up to the latest versions of UPS firmware and software, see the HP website (http://www.hp.com/go/rackandpower).
To benefit from the latest product enhancements, update to 1440 VA/1000 W (NA), 1200 VA/900 W (JPN/TWN) or 1500 VA/1000 W (INTL). NOTE: To download the latest versions of UPS firmware and software. UPS front panel Item 1 2 Description Battery compartment Control buttons and LED display Component identification 6 Component identification UPS R1500 G3 overview The HP UPS R1500 G3 features a 1U rack-mount design and offers power protection for loads up to the latest versions of UPS firmware and software, see the HP website (http://www.hp.com/go/rackandpower).
HP R1500 G3 UPS User Guide
Page 8
UPS R1500 G3 NA/JPN/TWN rear panel Item 1 2 3 4 5 6 7 8 9 10 Description UPS option card slot USB communications port Site Wiring Fault LED Serial communications port Network Transient Protector ...
UPS R1500 G3 NA/JPN/TWN rear panel Item 1 2 3 4 5 6 7 8 9 10 Description UPS option card slot USB communications port Site Wiring Fault LED Serial communications port Network Transient Protector ...
HP R1500 G3 UPS User Guide
Page 9
UPS R1500 G3 INTL rear panel Item 1 2 3 4 5 6 7 8 9 10 Description UPS option card slot Input power connector (IEC-320-C14 power inlet) Input circuit breaker USB communications port Serial communications port Network Transient Protector IN jack Voltage configuration DIP switches Network Transient Protector OUT jack Load segment 1 (two IEC-320-C13 output receptacles for surge and battery backup protection) Load segment 2 (two IEC-320-C13 output receptacles for surge and battery backup protection) Component identification 9
UPS R1500 G3 INTL rear panel Item 1 2 3 4 5 6 7 8 9 10 Description UPS option card slot Input power connector (IEC-320-C14 power inlet) Input circuit breaker USB communications port Serial communications port Network Transient Protector IN jack Voltage configuration DIP switches Network Transient Protector OUT jack Load segment 1 (two IEC-320-C13 output receptacles for surge and battery backup protection) Load segment 2 (two IEC-320-C13 output receptacles for surge and battery backup protection) Component identification 9
HP R1500 G3 UPS User Guide
Page 14
...Selecting the UPS voltage configuration Using a small tool, position the DIP switches according to download the latest version of HP Power Protector. Output voltage R1500 G3 JPN/TWN 100 V* 110 V R1500 G3 NA 110 V 120 V* R1500 G3 INTL 220 V 230 V* 240 V Input voltage range 90-106 V 99-116 V 99-116 V 108... host computer. Installation 14 Connect the UPS to the host computer. NOTE: An asterisk (*) indicates the default setting. Install HP Power Protector on the host computer. Connecting the serial communications port CAUTION: Use only the computer interface cable supplied with the...
...Selecting the UPS voltage configuration Using a small tool, position the DIP switches according to download the latest version of HP Power Protector. Output voltage R1500 G3 JPN/TWN 100 V* 110 V R1500 G3 NA 110 V 120 V* R1500 G3 INTL 220 V 230 V* 240 V Input voltage range 90-106 V 99-116 V 99-116 V 108... host computer. Installation 14 Connect the UPS to the host computer. NOTE: An asterisk (*) indicates the default setting. Install HP Power Protector on the host computer. Connecting the serial communications port CAUTION: Use only the computer interface cable supplied with the...
HP R1500 G3 UPS User Guide
Page 34
... input specifications NOTE: An asterisk (*) indicates the default setting. UPS model Utility voltage frequency (auto-sensing) R1500 G3 NA 50/60 Hz R1500 G3 JPN/TWN 50/60 Hz R1500 G3 INTL 50/60 Hz Available settings Branch circuit utility voltage rating (A) ("Selecting the UPS voltage configuration" on... TWN) IEC-320-C14 power inlet UPS output specifications UPS model R1500 G3 NA/JPN/TWN R1500 G3 INTL Output receptacles 4 x NEMA 5-15 4 x IEC-320-C13 Power protection specifications UPS model VA R1500 G3 NA R1500 G3 JPN/TWN 1440 1200 1320 Nominal power rating (W) 1000 900 1000...
... input specifications NOTE: An asterisk (*) indicates the default setting. UPS model Utility voltage frequency (auto-sensing) R1500 G3 NA 50/60 Hz R1500 G3 JPN/TWN 50/60 Hz R1500 G3 INTL 50/60 Hz Available settings Branch circuit utility voltage rating (A) ("Selecting the UPS voltage configuration" on... TWN) IEC-320-C14 power inlet UPS output specifications UPS model R1500 G3 NA/JPN/TWN R1500 G3 INTL Output receptacles 4 x NEMA 5-15 4 x IEC-320-C13 Power protection specifications UPS model VA R1500 G3 NA R1500 G3 JPN/TWN 1440 1200 1320 Nominal power rating (W) 1000 900 1000...
HP R1500 G3 UPS User Guide
Page 35
... the transition from charge mode to reach the rest mode. After approximately 24 hours, the batteries reach 90% charge at least 48 hours. UPS model R1500 G3 INTL VA 1500 Nominal power rating (W) 1000 Nominal voltage setting 220, 230, 240 Voltage specifications Configuration setting (VAC) 100 110 120 220 230 240 Available...
... the transition from charge mode to reach the rest mode. After approximately 24 hours, the batteries reach 90% charge at least 48 hours. UPS model R1500 G3 INTL VA 1500 Nominal power rating (W) 1000 Nominal voltage setting 220, 230, 240 Voltage specifications Configuration setting (VAC) 100 110 120 220 230 240 Available...