HP UPS Best Practices
Page 4
... and systems is extended on the other valuable functions. During an extended power event, HP Power Management Software facilitates a graceful, remote shutdown to providing an excellent USB, Serial or Web enable management capability, power management software allows the graceful shutdown of the attached...has been saved from a browser-based management console. In this manner, the HP UPS can manage scheduled shutdowns and sequential startups of receptacles on select UPS models). Page 4 of connected equipment. The UPS management software will run until the batteries are groups of ...
... and systems is extended on the other valuable functions. During an extended power event, HP Power Management Software facilitates a graceful, remote shutdown to providing an excellent USB, Serial or Web enable management capability, power management software allows the graceful shutdown of the attached...has been saved from a browser-based management console. In this manner, the HP UPS can manage scheduled shutdowns and sequential startups of receptacles on select UPS models). Page 4 of connected equipment. The UPS management software will run until the batteries are groups of ...
HP UPS Best Practices
Page 5
... Insight Manager and other SNMP management programs or used as a stand-alone management system. http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/software/module/ups/index.html Page 5 of attached equipments during a utility power failure. Manage ...web browser Include a Service Menu, a text-based menu that can be accessed through the serial connectors located on the front of the management module (local direct connection) and more remote devices over the network connection. Monitor the status of the UPS and manage a graceful shutdown of 27 The management module...
... Insight Manager and other SNMP management programs or used as a stand-alone management system. http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/software/module/ups/index.html Page 5 of attached equipments during a utility power failure. Manage ...web browser Include a Service Menu, a text-based menu that can be accessed through the serial connectors located on the front of the management module (local direct connection) and more remote devices over the network connection. Monitor the status of the UPS and manage a graceful shutdown of 27 The management module...
HP UPS Best Practices
Page 7
...of non-critical devices and extends battery backup for no-single-point-of 27 The R5500 model features an impressive 1500 watts per U (4500 watts total). The additional serial ports will provide greater power management control and flexible monitoring. Power Distribution... UPS management and monitoring, while providing prioritized, sequential shutdown of all network devices Provides details of HP Rackmount UPSs shield connected equipment with support for dual redundant UPS configuration for critical systems Enables independent control, startup and shutdown...
...of non-critical devices and extends battery backup for no-single-point-of 27 The R5500 model features an impressive 1500 watts per U (4500 watts total). The additional serial ports will provide greater power management control and flexible monitoring. Power Distribution... UPS management and monitoring, while providing prioritized, sequential shutdown of all network devices Provides details of HP Rackmount UPSs shield connected equipment with support for dual redundant UPS configuration for critical systems Enables independent control, startup and shutdown...
HP UPS Best Practices
Page 8
Page 8 of valuable rack space, while delivering key benefits such as Enhanced Battery Management, Load Segment Control, and serial and USB ports for data exchange. This leading-edge UPS features a spacesaving 2U design that delivers up to provide key advantages ...efficiency and a smaller footprint with less weight. The densest, most power-packed UPS available, the HP R3000 delivers more watts per U than any other UPS, enabling more valuable rack space to be connected to optional Extended Runtime Modules (ERMs), allowing customers to be utilized by servers, storage and networking...
Page 8 of valuable rack space, while delivering key benefits such as Enhanced Battery Management, Load Segment Control, and serial and USB ports for data exchange. This leading-edge UPS features a spacesaving 2U design that delivers up to provide key advantages ...efficiency and a smaller footprint with less weight. The densest, most power-packed UPS available, the HP R3000 delivers more watts per U than any other UPS, enabling more valuable rack space to be connected to optional Extended Runtime Modules (ERMs), allowing customers to be utilized by servers, storage and networking...
HP UPS Best Practices
Page 13
...13 of 750VA/500 watts and less, the HP T750 G2 delivers reliable protection for entry level servers, desktops, work stations and small peripherals. With serial and USB connectivity for data exchange with the host computer. HP Tower UPS Models HP T750 G2 UPS Ideal for small and medium... businesses and desktop/workstation environments with power requirements of 27 These UPSs also feature serial and USB ports for multiple ...
...13 of 750VA/500 watts and less, the HP T750 G2 delivers reliable protection for entry level servers, desktops, work stations and small peripherals. With serial and USB connectivity for data exchange with the host computer. HP Tower UPS Models HP T750 G2 UPS Ideal for small and medium... businesses and desktop/workstation environments with power requirements of 27 These UPSs also feature serial and USB ports for multiple ...
HP UPS R3000 User Guide
Page 3
Contents Component identification ...6 UPS R3000 overview ...6 UPS front panel ...6 UPS front panel controls ...7 UPS front panel LED indicators...8 HP UPS R3000 models ...8 UPS R3000 NA and R3000j JPN rear panel 9 UPS R3000h NA and R3000h JPN rear panel 10 ... ...14 Installing the UPS ...18 Connecting the battery leads ...19 Attaching the UPS front bezel ...19 Connecting the serial communications port 19 Connecting the REPO port...20 Connecting the ground bonding cable 22 Connecting the UPS to utility power...22 Connecting devices to the UPS ...23 Connecting the UPS cord retention clips 23...
Contents Component identification ...6 UPS R3000 overview ...6 UPS front panel ...6 UPS front panel controls ...7 UPS front panel LED indicators...8 HP UPS R3000 models ...8 UPS R3000 NA and R3000j JPN rear panel 9 UPS R3000h NA and R3000h JPN rear panel 10 ... ...14 Installing the UPS ...18 Connecting the battery leads ...19 Attaching the UPS front bezel ...19 Connecting the serial communications port 19 Connecting the REPO port...20 Connecting the ground bonding cable 22 Connecting the UPS to utility power...22 Connecting devices to the UPS ...23 Connecting the UPS cord retention clips 23...
HP UPS R3000 User Guide
Page 4
Verifying the REPO port connection...31 Powering down the UPS...31 Power management ...32 Power management software...32 Maintenance ...33 Removing the UPS front bezel ...33 Removing the ERM front ... replacement procedure 36 Testing the new battery module...38 Replacing the UPS ...38 Replacing the ERM ...38 Updating the UPS firmware ...39 Configuring a USB to serial converter 39 Reassigning the USB COM ports...40 Troubleshooting ...41 LED and audible alarm troubleshooting ...41 UPS is in Auto-Bypass mode ...42 General alarm...
Verifying the REPO port connection...31 Powering down the UPS...31 Power management ...32 Power management software...32 Maintenance ...33 Removing the UPS front bezel ...33 Removing the ERM front ... replacement procedure 36 Testing the new battery module...38 Replacing the UPS ...38 Replacing the ERM ...38 Updating the UPS firmware ...39 Configuring a USB to serial converter 39 Reassigning the USB COM ports...40 Troubleshooting ...41 LED and audible alarm troubleshooting ...41 UPS is in Auto-Bypass mode ...42 General alarm...
HP UPS R3000 User Guide
Page 11
... feature shuts down UPS units operating under either utility or battery power. UPS R3000 INT rear panel Item 1 2 3 4 5 6 7 8 9 10 11 Description REPO port ERM connector Serial communications port/options slot Load segment 1 (three IEC-320-C13 receptacles) Load segment 2 (three IEC-320-C13 receptacles) Load segment 3 (three IEC-320-C13 receptacles... is used in conjunction with a main disconnect device that removes the AC source from a remote location. To use this feature, the REPO port must be connected to be switched off from the input of the UPS. Component identification 11
... feature shuts down UPS units operating under either utility or battery power. UPS R3000 INT rear panel Item 1 2 3 4 5 6 7 8 9 10 11 Description REPO port ERM connector Serial communications port/options slot Load segment 1 (three IEC-320-C13 receptacles) Load segment 2 (three IEC-320-C13 receptacles) Load segment 3 (three IEC-320-C13 receptacles... is used in conjunction with a main disconnect device that removes the AC source from a remote location. To use this feature, the REPO port must be connected to be switched off from the input of the UPS. Component identification 11
HP UPS R3000 User Guide
Page 19
Installation 19 IMPORTANT: Power management software requires the communications port to be appropriately cabled to the host computer. Connecting the battery leads Attaching the UPS front bezel Connecting the serial communications port CAUTION: Use only the computer interface cable supplied with the UPS to connect the communications port to the host computer.
Installation 19 IMPORTANT: Power management software requires the communications port to be appropriately cabled to the host computer. Connecting the battery leads Attaching the UPS front bezel Connecting the serial communications port CAUTION: Use only the computer interface cable supplied with the UPS to connect the communications port to the host computer.
HP UPS R3000 User Guide
Page 39
...This procedure was tested on your system configuration, a driver download might be downloaded from the rack. Connect the USB to serial converter to the USB port on systems that is assigned to serial converter device. Click the Hardware tab. 4. The Device Manager screen appears. 5. Remove the ERM from...drivers.com/drivers/123/123294.htm). Updating the UPS firmware To update the UPS firmware, see the HP website (http://www.hp.com/go/rackandpower). The driver can be required to serial converter (part number 304098-001). In the tree displayed in the left panel, click the Ports (...
...This procedure was tested on your system configuration, a driver download might be downloaded from the rack. Connect the USB to serial converter to the USB port on systems that is assigned to serial converter device. Click the Hardware tab. 4. The Device Manager screen appears. 5. Remove the ERM from...drivers.com/drivers/123/123294.htm). Updating the UPS firmware To update the UPS firmware, see the HP website (http://www.hp.com/go/rackandpower). The driver can be required to serial converter (part number 304098-001). In the tree displayed in the left panel, click the Ports (...
HP UPS R3000 User Guide
Page 65
... 11 REPO port, overview 11 REPO port, specifications 49 REPO port, verifying connection 31 required information 52 required tools 13 Reset button, location 7 runtime specifications 48 S safety considerations 13, 35 selecting a site 14 serial port 19 series number 55 settings 30 shipping the UPS 14 site requirements 14 ..., installing 13, 18 UPS, replacing 38 Utility LED, location 8 Utility LED, troubleshooting 41 utility power condition 44 utility power, connecting 22 V voltage specifications 47 voltage, configuring 28, 30 W warranties 53 weight, battery 35 weight, ERM 46 weight, UPS 46 Index 65
... 11 REPO port, overview 11 REPO port, specifications 49 REPO port, verifying connection 31 required information 52 required tools 13 Reset button, location 7 runtime specifications 48 S safety considerations 13, 35 selecting a site 14 serial port 19 series number 55 settings 30 shipping the UPS 14 site requirements 14 ..., installing 13, 18 UPS, replacing 38 Utility LED, location 8 Utility LED, troubleshooting 41 utility power condition 44 utility power, connecting 22 V voltage specifications 47 voltage, configuring 28, 30 W warranties 53 weight, battery 35 weight, ERM 46 weight, UPS 46 Index 65
HP 3 Phase UPS User Guide
Page 5
......89 Replacing the UPS ...89 Replacing the ERM ...90 Updating the UPS firmware ...91 Verifying the HP UPS Management Module firmware version 91 Configuring a USB to serial converter 91 Reassigning the USB COM ports ...92 Troubleshooting ...94 LED and audible alarm troubleshooting ...94 ...Silencing an audible alarm ...95 Abnormal output voltage at startup ...95 Battery breaker ...95 Battery connection condition ...96 Battery low condition ...
......89 Replacing the UPS ...89 Replacing the ERM ...90 Updating the UPS firmware ...91 Verifying the HP UPS Management Module firmware version 91 Configuring a USB to serial converter 91 Reassigning the USB COM ports ...92 Troubleshooting ...94 LED and audible alarm troubleshooting ...94 ...Silencing an audible alarm ...95 Abnormal output voltage at startup ...95 Battery breaker ...95 Battery connection condition ...96 Battery low condition ...
HP 3 Phase UPS User Guide
Page 75
... device Direction from the UPS - No connection 2 TxD Transmit to the UPS communication port using the supplied communication cable. X-Slot 1 (independent) X-Slot 2 (multiplexed) HP UPS Management Module HP Parallel UPS Card HP UPS Management Module Not in one of the available bays. Communication options The UPS has serial communication capabilities through the DB-9 communication port...
... device Direction from the UPS - No connection 2 TxD Transmit to the UPS communication port using the supplied communication cable. X-Slot 1 (independent) X-Slot 2 (multiplexed) HP UPS Management Module HP Parallel UPS Card HP UPS Management Module Not in one of the available bays. Communication options The UPS has serial communication capabilities through the DB-9 communication port...
UPS R6000 Models User Guide
Page 19
...Units Extend the capabilities of the UPS R6000 by up to 18 minutes. Two are provided with load segments 1, 2, or 3. Two ERMs can be serially connected to each UPS, increasing the total available runtime by attaching a PDU to the high current receptacle associated with the PDU kit. 1-10... HP Uninterruptible Power System R6000 Models User Guide The High to Low Voltage Transformer (250 VA) can be connected to the UPS R6000 to supply two low-voltage outlets at 250 VA. To...
...Units Extend the capabilities of the UPS R6000 by up to 18 minutes. Two are provided with load segments 1, 2, or 3. Two ERMs can be serially connected to each UPS, increasing the total available runtime by attaching a PDU to the high current receptacle associated with the PDU kit. 1-10... HP Uninterruptible Power System R6000 Models User Guide The High to Low Voltage Transformer (250 VA) can be connected to the UPS R6000 to supply two low-voltage outlets at 250 VA. To...
HP Power Protector User Guide
Page 11
...are powered by a UPS and communicate with two UPS Network Modules over the network HPPP Administrator UPS Network Power connection Communication path Serial connection Overview 11 Supported hardware configurations HPPP requires that is plugged into the HPPP Administrator over the network. UPSs can ...; Configuration F (on page 13)-One HPPP Administrator is connected directly to the network. A remote workstation can be attached in any of the UPS. NOTE: For the latest supported operating systems, see the HP website (http://www.hp.com/go/rackandpower). Item 1 2 3 4 Green Red...
...are powered by a UPS and communicate with two UPS Network Modules over the network HPPP Administrator UPS Network Power connection Communication path Serial connection Overview 11 Supported hardware configurations HPPP requires that is plugged into the HPPP Administrator over the network. UPSs can ...; Configuration F (on page 13)-One HPPP Administrator is connected directly to the network. A remote workstation can be attached in any of the UPS. NOTE: For the latest supported operating systems, see the HP website (http://www.hp.com/go/rackandpower). Item 1 2 3 4 Green Red...
HP Power Protector User Guide
Page 12
This HPPP Administrator communicates to the HPPP Client servers over the network Power connection Communication path Serial connection Overview 12 NOTE: Up to begin a graceful shutdown in the event of a power failure or other configured shutdown events. Item 1 2 3 4 5 6 Green Red Black Description UPS ... the HPPP Administrator or Client over the network to 35 HPPP Clients can be managed by one server as an HPPP Administrator and it is serially attached to the UPS. Configuration B This figure illustrates one HPPP Administrator.
This HPPP Administrator communicates to the HPPP Client servers over the network Power connection Communication path Serial connection Overview 12 NOTE: Up to begin a graceful shutdown in the event of a power failure or other configured shutdown events. Item 1 2 3 4 5 6 Green Red Black Description UPS ... the HPPP Administrator or Client over the network to 35 HPPP Clients can be managed by one server as an HPPP Administrator and it is serially attached to the UPS. Configuration B This figure illustrates one HPPP Administrator.
HP Power Protector User Guide
Page 48
... side of menu options on the left navigation frame Click Help to view online help. NOTE: Passwords are discovered. A quick scan discovers all USB or serially connected UPSs are logged in with a user name and password. For an Administrator, all available power sources. For a Client, all HPPP Administrators and UPS Network Modules...
... side of menu options on the left navigation frame Click Help to view online help. NOTE: Passwords are discovered. A quick scan discovers all USB or serially connected UPSs are logged in with a user name and password. For an Administrator, all available power sources. For a Client, all HPPP Administrators and UPS Network Modules...
HP Power Protector User Guide
Page 51
...MAC address of the node • Description-A description of the node • Serial number-The serial number of the node • Class-The device type, for example, RS-232 device, USB device, HP Power Protector, or UPS Network Module • OS type-The node operating ... the web interface for the agent ( Communication Loss) HTTP Connection, HTTPS Connection, or • Load alarm threshold-A user specified threshold value that are outside the network segment. The Range scan screen appears. Discover USB- and serially-connected UPSs using the HPPP Client. o Click Range scan to...
...MAC address of the node • Description-A description of the node • Serial number-The serial number of the node • Class-The device type, for example, RS-232 device, USB device, HP Power Protector, or UPS Network Module • OS type-The node operating ... the web interface for the agent ( Communication Loss) HTTP Connection, HTTPS Connection, or • Load alarm threshold-A user specified threshold value that are outside the network segment. The Range scan screen appears. Discover USB- and serially-connected UPSs using the HPPP Client. o Click Range scan to...
HP Power Protector User Guide
Page 125
... about enabling virtualization, see the KVM virtualization host configuration and installation guide. Check firewalls and blockers. 2. Configure communication between HPPP and the HP Network Module: iptables -I OUTPUT -p tcp --dport 80 -j ACCEPT iptables -I INPUT -p tcp --dport 4679 -j ACCEPT iptables -I INPUT ...For TCP port 80 on a virtual operating system 125 b. Virtualized environment configuration HP recommends installing HPPP clients on RHEL. UPS devices through RS232 (serial) connectivity are not supported on the virtual layer of the virtual host, configure the ...
... about enabling virtualization, see the KVM virtualization host configuration and installation guide. Check firewalls and blockers. 2. Configure communication between HPPP and the HP Network Module: iptables -I OUTPUT -p tcp --dport 80 -j ACCEPT iptables -I INPUT -p tcp --dport 4679 -j ACCEPT iptables -I INPUT ...For TCP port 80 on a virtual operating system 125 b. Virtualized environment configuration HP recommends installing HPPP clients on RHEL. UPS devices through RS232 (serial) connectivity are not supported on the virtual layer of the virtual host, configure the ...
Updating Firmware via USB to Serial Connection
Page 1
... install the converter. For Windows Server, reduce the Receive Buffer and Transmit Buffer to the low setting by using the HP USB to serial converter (part number 304098-001). Choose the lowest, most dependable Receive and Transmit buffers by scrolling down menu, select ... click System. -orFor Windows Server, click Start, select Control Panel, and then doubleclick System. 3. a. Important Information USB to Serial Connection Configuring a USB to serial converter NOTE: This procedure was tested on the Windows® XP Professional, Windows Server® 2003, and Windows® Vista ...
... install the converter. For Windows Server, reduce the Receive Buffer and Transmit Buffer to the low setting by using the HP USB to serial converter (part number 304098-001). Choose the lowest, most dependable Receive and Transmit buffers by scrolling down menu, select ... click System. -orFor Windows Server, click Start, select Control Panel, and then doubleclick System. 3. a. Important Information USB to Serial Connection Configuring a USB to serial converter NOTE: This procedure was tested on the Windows® XP Professional, Windows Server® 2003, and Windows® Vista ...