HP R/T3000 G2 UPS User Guide
Page 61
... Available settings utility Branch circuit voltage (VAC) rating (A) 100, 110, 120, 127 30 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 20 240 R/T3000 INTL 50/60 200/208, 220, 230, 16 240 1 The output voltage is 204 for this setting.
... Available settings utility Branch circuit voltage (VAC) rating (A) 100, 110, 120, 127 30 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 20 240 R/T3000 INTL 50/60 200/208, 220, 230, 16 240 1 The output voltage is 204 for this setting.
HP R/T3000 G2 UPS User Guide
Page 62
... Specification 12 V, 5 AH, sealed, maintenance-free, rechargeable, valve regulated lead-acid batteries with a 3-5 year service life at 25°C (77°F). Specifications 62 R/T3000 INTL - - - Output receptacles 1 x L6-20R 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-...320-C13 1 x IEC-320-C19 Power protection specifications UPS model VA R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL 2880 / 2400 3300 3300 Nominal power rating (W) 2700 / 2250 3000 3000 Nominal voltage setting 120/100 204 230 Output tolerance specifications Source of...
... Specification 12 V, 5 AH, sealed, maintenance-free, rechargeable, valve regulated lead-acid batteries with a 3-5 year service life at 25°C (77°F). Specifications 62 R/T3000 INTL - - - Output receptacles 1 x L6-20R 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-...320-C13 1 x IEC-320-C19 Power protection specifications UPS model VA R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL 2880 / 2400 3300 3300 Nominal power rating (W) 2700 / 2250 3000 3000 Nominal voltage setting 120/100 204 230 Output tolerance specifications Source of...
HP R/T3000 G2 UPS User Guide
Page 64
Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). UPS spare parts list Item Description 1 UPS unit a) NA/JPN b) HV NA/JPN* c) INTL* 2 UPS Network Module 3 Battery module 4 Mounting rails with screws* 5 UPS/ERM mounting brackets* 6 Cord retention clips (6)* 7 Serial download cable* * not shown Spare part number - 638840-001 638841-001 638842-001 636934-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 64 To replace parts under warranty, contact an HP authorized service representative.
Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). UPS spare parts list Item Description 1 UPS unit a) NA/JPN b) HV NA/JPN* c) INTL* 2 UPS Network Module 3 Battery module 4 Mounting rails with screws* 5 UPS/ERM mounting brackets* 6 Cord retention clips (6)* 7 Serial download cable* * not shown Spare part number - 638840-001 638841-001 638842-001 636934-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 64 To replace parts under warranty, contact an HP authorized service representative.
HP UPS R/T3000 G2 Installation Instructions
Page 2
...UPS kit. 1. Install the equipment in an environment compatible with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for a country-specific cord and one C13 extension bar. Check the battery recharge date ... operating ambient temperature of the rack environment might have on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for directions. 2. Loosen the wing nuts or hex nuts, and then extend the brackets to its installation location. 3. ...
...UPS kit. 1. Install the equipment in an environment compatible with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for a country-specific cord and one C13 extension bar. Check the battery recharge date ... operating ambient temperature of the rack environment might have on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for directions. 2. Loosen the wing nuts or hex nuts, and then extend the brackets to its installation location. 3. ...
HP UPS R/T3000 Installation Instructions
Page 2
... where the unit will be maintained. NOTE: All models ship with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for the specific UPS as stated in "Input specifications" in a closed or multi-unit rack ...8226; Elevated operating ambient temperature-If the equipment is on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for safe operation of the rack environment might have on the host computer. If the date on the bottom of conductive ...
... where the unit will be maintained. NOTE: All models ship with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for the specific UPS as stated in "Input specifications" in a closed or multi-unit rack ...8226; Elevated operating ambient temperature-If the equipment is on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for safe operation of the rack environment might have on the host computer. If the date on the bottom of conductive ...
HP R/T2200 UPS User Guide
Page 3
Contents Component identification ...6 UPS front panel ...6 UPS front panel controls and LED indicators 7 UPS R/T2200 NA/JPN/TWN rear panel...8 UPS R/T2200 INTL rear panel ...9 REPO port ...10 Installation ...12 Precautions...12 Preparing to install the hardware...12 Required tools ...12 Selecting a site...12 Readying the equipment ...13 ...
Contents Component identification ...6 UPS front panel ...6 UPS front panel controls and LED indicators 7 UPS R/T2200 NA/JPN/TWN rear panel...8 UPS R/T2200 INTL rear panel ...9 REPO port ...10 Installation ...12 Precautions...12 Preparing to install the hardware...12 Required tools ...12 Selecting a site...12 Readying the equipment ...13 ...
HP R/T2200 UPS User Guide
Page 9
... Power sensitivity adjustment dial Ground bonding screw ERM connector For information about controlling load segments remotely, see "Power management software (on page 32)." UPS R/T2200 INTL rear panel Item 1 2 Description Load segment 1 (one IEC-320-C13 output receptacle for surge and battery backup protection) Load segment 2 (one NEMA 5-20 output receptacle...
... Power sensitivity adjustment dial Ground bonding screw ERM connector For information about controlling load segments remotely, see "Power management software (on page 32)." UPS R/T2200 INTL rear panel Item 1 2 Description Load segment 1 (one IEC-320-C13 output receptacle for surge and battery backup protection) Load segment 2 (one NEMA 5-20 output receptacle...
HP R/T2200 UPS User Guide
Page 20
.../TW N 110 V 99-116 V Up Down - - 100 V* 90-106 V Down Up - - (JPN/TWN) 120 V 108-127 V Down Down Down Down R/T2200 INTL 230 V 20-7243 V Up Up Up* Up 230 V* (INTL) 207-243 V Up Down - - 220 V 198-233 V Down Up - - 240 V 216-254 V Down Down Down Down Connecting the host computer Installation...
.../TW N 110 V 99-116 V Up Down - - 100 V* 90-106 V Down Up - - (JPN/TWN) 120 V 108-127 V Down Down Down Down R/T2200 INTL 230 V 20-7243 V Up Up Up* Up 230 V* (INTL) 207-243 V Up Down - - 220 V 198-233 V Down Up - - 240 V 216-254 V Down Down Down Down Connecting the host computer Installation...
HP R/T2200 UPS User Guide
Page 21
...and configure the software, see the software user guide. The software user guide is available for download from the HP website (http://www.hp.com/go /rackandpower) to download the latest version of HP Power Manager. Connecting the serial communications port CAUTION: Use only the computer interface cable supplied with the UPS. Connecting... load devices are shutdown gracefully. Connect the UPS to a host computer using HPPM, connect the Management Server to an unswitched output receptacle ("UPS R/T2200 INTL rear panel" on page 9, "UPS R/T2200 NA/JPN/TWN rear panel" on the host computer. See the...
...and configure the software, see the software user guide. The software user guide is available for download from the HP website (http://www.hp.com/go /rackandpower) to download the latest version of HP Power Manager. Connecting the serial communications port CAUTION: Use only the computer interface cable supplied with the UPS. Connecting... load devices are shutdown gracefully. Connect the UPS to a host computer using HPPM, connect the Management Server to an unswitched output receptacle ("UPS R/T2200 INTL rear panel" on page 9, "UPS R/T2200 NA/JPN/TWN rear panel" on the host computer. See the...
HP R/T2200 UPS User Guide
Page 23
... not use extension cords. 1. The grounding plug is not included. For more information about receptacle control, see "Power management software (on the UPS rear panel (INTL model only). 2. Connecting devices to the UPS CAUTION: Do not plug laser printers into a grounded (earthed) electrical outlet that is installed near the equipment and...
... not use extension cords. 1. The grounding plug is not included. For more information about receptacle control, see "Power management software (on the UPS rear panel (INTL model only). 2. Connecting devices to the UPS CAUTION: Do not plug laser printers into a grounded (earthed) electrical outlet that is installed near the equipment and...
HP R/T2200 UPS User Guide
Page 24
... illuminates solid green, indicating that power is listed in "Precautions (on the rear panel of the UPS using the jumper cords included with the UPS (INTL model). Installing the ERM as a tower Before installing the unit, review and adhere to all warnings provided in amps, multiply the number of amps by...
... illuminates solid green, indicating that power is listed in "Precautions (on the rear panel of the UPS using the jumper cords included with the UPS (INTL model). Installing the ERM as a tower Before installing the unit, review and adhere to all warnings provided in amps, multiply the number of amps by...
HP R/T2200 UPS User Guide
Page 31
... is turned clockwise, the UPS becomes more tolerant of rear panel components, see "UPS R/T2200 NA/JPN/TWN rear panel (on page 8)" or "UPS R/T2200 INTL rear panel (on page 9)." Powering down all connected load devices. 2. Wait at least 60 seconds for this dial. NOTE: While testing, operate connected equipment in...
... is turned clockwise, the UPS becomes more tolerant of rear panel components, see "UPS R/T2200 NA/JPN/TWN rear panel (on page 8)" or "UPS R/T2200 INTL rear panel (on page 9)." Powering down all connected load devices. 2. Wait at least 60 seconds for this dial. NOTE: While testing, operate connected equipment in...
HP R/T2200 UPS User Guide
Page 40
...) 44.5 cm (17.5 in) 28.6 kg (63 lb) UPS input specifications NOTE: An asterisk (*) indicates the default setting. UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Utility voltage Available settings frequency (Hz) utility voltage (VAC) 50/60 100, 110, 120* 50/60 220, 230*, 240 Branch circuit rating (A) 20 15 Line... Nondetachable power cord with NEMA 5-20 plug Detachable power cord with IEC-320-C20 plug UPS output specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Output receptacles 4 x NEMA 5-15R, 4 x NEMA 515/20R 8 x IEC-320-C13 Maximum current 18.3 A 9.5 A Specifications 40
...) 44.5 cm (17.5 in) 28.6 kg (63 lb) UPS input specifications NOTE: An asterisk (*) indicates the default setting. UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Utility voltage Available settings frequency (Hz) utility voltage (VAC) 50/60 100, 110, 120* 50/60 220, 230*, 240 Branch circuit rating (A) 20 15 Line... Nondetachable power cord with NEMA 5-20 plug Detachable power cord with IEC-320-C20 plug UPS output specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Output receptacles 4 x NEMA 5-15R, 4 x NEMA 515/20R 8 x IEC-320-C13 Maximum current 18.3 A 9.5 A Specifications 40
HP R/T2200 UPS User Guide
Page 41
Specifications 41 Power protection specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL VA 2200 2200 Nominal power Nominal voltage rating (W) setting 1600 100, 110, 120 1600 220, 230, 240 Voltage specifications Configuration setting (VAC) 100 110 120 ...
Specifications 41 Power protection specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL VA 2200 2200 Nominal power Nominal voltage rating (W) setting 1600 100, 110, 120 1600 220, 230, 240 Voltage specifications Configuration setting (VAC) 100 110 120 ...
HP R/T2200 UPS User Guide
Page 43
Spares 43 To replace parts under warranty, contact an HP authorized service representative. Spare parts list Item UPS unit NA UPS unit JPN/TWN UPS unit INTL ERM unit UPS/ERM tower stand UPS/ERM mounting hardware UPS battery Spare part number 410039-001 410040-291 410041-B31 410045-001 410042-001 415694-001 416727-001 Hardware options For information on the supported hardware options, see the HP website (http://www.hp.com/go/rackandpower). Spares Ordering spares To order a spare, visit the HP website (http://h61003.www6.hp.com).
Spares 43 To replace parts under warranty, contact an HP authorized service representative. Spare parts list Item UPS unit NA UPS unit JPN/TWN UPS unit INTL ERM unit UPS/ERM tower stand UPS/ERM mounting hardware UPS battery Spare part number 410039-001 410040-291 410041-B31 410045-001 410042-001 415694-001 416727-001 Hardware options For information on the supported hardware options, see the HP website (http://www.hp.com/go/rackandpower). Spares Ordering spares To order a spare, visit the HP website (http://h61003.www6.hp.com).
HP R/T2200 UPS User Guide
Page 54
... 7 power protection specifications 41 power sensitivity adjustment dial, location 8, 9 power sensitivity adjustment dial, setting 30 powering down 31 powering up 24 problem diagnosis 37 R R/T2200 INTL 7, 9 R/T2200 NA/JPN/TWN 7, 8 rack-to-tower conversion 13, 24 rear panel components 8, 9 regulatory compliance identification numbers 46 regulatory compliance notices 46, 48 replacing the...
... 7 power protection specifications 41 power sensitivity adjustment dial, location 8, 9 power sensitivity adjustment dial, setting 30 powering down 31 powering up 24 problem diagnosis 37 R R/T2200 INTL 7, 9 R/T2200 NA/JPN/TWN 7, 8 rack-to-tower conversion 13, 24 rear panel components 8, 9 regulatory compliance identification numbers 46 regulatory compliance notices 46, 48 replacing the...
HP UPS R/T3000 User Guide
Page 59
... voltage frequency (Hz) 50/60 Available settings utility voltage (VAC) 100, 110, 120, 127 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 240 R/T3000 INTL 50/60 200/208, 220, 230, 240 1 The output voltage is 204 for this setting. Branch circuit rating (A) 30 20 16 Line cord Nondetachable power...
... voltage frequency (Hz) 50/60 Available settings utility voltage (VAC) 100, 110, 120, 127 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 240 R/T3000 INTL 50/60 200/208, 220, 230, 240 1 The output voltage is 204 for this setting. Branch circuit rating (A) 30 20 16 Line cord Nondetachable power...
HP UPS R/T3000 User Guide
Page 60
...-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL VA 2880 3300 3300 Nominal power rating (W) 2700 Nominal voltage setting 100, 110, 120, 127 3000 204, 220, 230, 240 3000 204, 220, 230, 240...
...-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL VA 2880 3300 3300 Nominal power rating (W) 2700 Nominal voltage setting 100, 110, 120, 127 3000 204, 220, 230, 240 3000 204, 220, 230, 240...
HP UPS R/T3000 User Guide
Page 63
Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). UPS spare parts list Item Description 1 UPS unit NA/JPN * UPS unit HV NA/JPN * UPS unit INTL 2 X-slot serial card 3 Battery module * Mounting rails with screws * UPS/ERM mounting brackets * Cord retention clips * Serial download cable * not shown Spare part number 517699-001 517700-001 517701-001 419180-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 63 To replace parts under warranty, contact an HP authorized service representative.
Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). UPS spare parts list Item Description 1 UPS unit NA/JPN * UPS unit HV NA/JPN * UPS unit INTL 2 X-slot serial card 3 Battery module * Mounting rails with screws * UPS/ERM mounting brackets * Cord retention clips * Serial download cable * not shown Spare part number 517699-001 517700-001 517701-001 419180-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 63 To replace parts under warranty, contact an HP authorized service representative.
HP UPS R/T3000 User Guide
Page 79
R/T3000 INTL 11 R/T3000 models 9 R/T3000 NA 9 R/T3000h JPN 10 R/T3000h NA 10 R/T3000j JPN 9 rack-to-tower conversion 26, 35 rails, installing 14 rear panel connectors 9, ...