... Available settings utility Branch circuit voltage (VAC) rating (A) 100, 110, 120, 127 30 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 20 240 R/T3000 INTL 50/60 200/208, 220, 230, 16 240 1 The output voltage is 204 for this setting.
... Available settings utility Branch circuit voltage (VAC) rating (A) 100, 110, 120, 127 30 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 20 240 R/T3000 INTL 50/60 200/208, 220, 230, 16 240 1 The output voltage is 204 for this setting.
HP R/T3000 G2 UPS User Guide
Page 62
... 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model VA R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL 2880 / 2400 3300 3300 Nominal power rating (W) 2700 / 2250 3000 3000 Nominal voltage setting 120/100 204 230 Output tolerance specifications Source of power Utility... Voltage Specification 12 V, 5 AH, sealed, maintenance-free, rechargeable, valve regulated lead-acid batteries with a 3-5 year service life at 25°C (77°F). Specifications 62 R/T3000 INTL - - - Load segment - 2 - 1 - 2 -
... 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model VA R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL 2880 / 2400 3300 3300 Nominal power rating (W) 2700 / 2250 3000 3000 Nominal voltage setting 120/100 204 230 Output tolerance specifications Source of power Utility... Voltage Specification 12 V, 5 AH, sealed, maintenance-free, rechargeable, valve regulated lead-acid batteries with a 3-5 year service life at 25°C (77°F). Specifications 62 R/T3000 INTL - - - Load segment - 2 - 1 - 2 -
HP R/T3000 G2 UPS User Guide
Page 64
Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). To replace parts under warranty, contact an HP authorized service representative. UPS spare parts list Item Description 1 UPS unit a) NA/JPN b) HV NA/JPN* c) INTL* 2 UPS Network Module 3 Battery module 4 Mounting rails with screws* 5 UPS/ERM mounting brackets* 6 Cord retention clips (6)* 7 Serial download cable* * not shown Spare part number - 638840-001 638841-001 638842-001 636934-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 64
Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). To replace parts under warranty, contact an HP authorized service representative. UPS spare parts list Item Description 1 UPS unit a) NA/JPN b) HV NA/JPN* c) INTL* 2 UPS Network Module 3 Battery module 4 Mounting rails with screws* 5 UPS/ERM mounting brackets* 6 Cord retention clips (6)* 7 Serial download cable* * not shown Spare part number - 638840-001 638841-001 638842-001 636934-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 64
HP UPS R/T3000 G2 Installation Instructions
Page 2
...8226; The full weight of the rack environment might have on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for square- A rack may become unstable if more than direct connections to the branch circuit, such as the use the ... The R/T3000h NA/JPN models ship with a nondetachable input power cord with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for a country-specific cord and one component is extended for any reason. Tools and materials The...
...8226; The full weight of the rack environment might have on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for square- A rack may become unstable if more than direct connections to the branch circuit, such as the use the ... The R/T3000h NA/JPN models ship with a nondetachable input power cord with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for a country-specific cord and one component is extended for any reason. Tools and materials The...
HP UPS R/T3000 Installation Instructions
Page 2
...plan the rack installation so that the heaviest item is on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for directions. 2. The computer interface cable is not needed for the specific UPS as stated in "Input specifications" in ... The R/T3000h NA/JPN models ship with a nondetachable input power cord with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for a country-specific cord and one component is extended for any reason. NOTE: All models ship...
...plan the rack installation so that the heaviest item is on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for directions. 2. The computer interface cable is not needed for the specific UPS as stated in "Input specifications" in ... The R/T3000h NA/JPN models ship with a nondetachable input power cord with an L6-20 plug and one C13 extension bar. • The R/T3000 INTL model has an IEC-20-C19 input power receptacle for a country-specific cord and one component is extended for any reason. NOTE: All models ship...
HP R/T2200 UPS User Guide
Page 3
Contents Component identification ...6 UPS front panel ...6 UPS front panel controls and LED indicators 7 UPS R/T2200 NA/JPN/TWN rear panel...8 UPS R/T2200 INTL rear panel ...9 REPO port ...10 Installation ...12 Precautions...12 Preparing to install the hardware...12 Required tools ...12 Selecting a site...12 Readying the equipment ...13 ...
Contents Component identification ...6 UPS front panel ...6 UPS front panel controls and LED indicators 7 UPS R/T2200 NA/JPN/TWN rear panel...8 UPS R/T2200 INTL rear panel ...9 REPO port ...10 Installation ...12 Precautions...12 Preparing to install the hardware...12 Required tools ...12 Selecting a site...12 Readying the equipment ...13 ...
HP R/T2200 UPS User Guide
Page 9
... Power sensitivity adjustment dial Ground bonding screw ERM connector For information about controlling load segments remotely, see "Power management software (on page 32)." UPS R/T2200 INTL rear panel Item 1 2 Description Load segment 1 (one IEC-320-C13 output receptacle for surge and battery backup protection) Load segment 2 (one NEMA 5-20 output receptacle...
... Power sensitivity adjustment dial Ground bonding screw ERM connector For information about controlling load segments remotely, see "Power management software (on page 32)." UPS R/T2200 INTL rear panel Item 1 2 Description Load segment 1 (one IEC-320-C13 output receptacle for surge and battery backup protection) Load segment 2 (one NEMA 5-20 output receptacle...
HP R/T2200 UPS User Guide
Page 20
.../TW N 110 V 99-116 V Up Down - - 100 V* 90-106 V Down Up - - (JPN/TWN) 120 V 108-127 V Down Down Down Down R/T2200 INTL 230 V 20-7243 V Up Up Up* Up 230 V* (INTL) 207-243 V Up Down - - 220 V 198-233 V Down Up - - 240 V 216-254 V Down Down Down Down Connecting the host computer Installation...
.../TW N 110 V 99-116 V Up Down - - 100 V* 90-106 V Down Up - - (JPN/TWN) 120 V 108-127 V Down Down Down Down R/T2200 INTL 230 V 20-7243 V Up Up Up* Up 230 V* (INTL) 207-243 V Up Down - - 220 V 198-233 V Down Up - - 240 V 216-254 V Down Down Down Down Connecting the host computer Installation...
HP R/T2200 UPS User Guide
Page 21
.... CAUTION: Using a USB to serial converter cable will damage the UPS. The software user guide is available for download from the HP website (http://www.hp.com/go /rackandpower) to the host computer. CAUTION: Using a USB to the host computer. Connecting the serial communications port CAUTION:...devices are shutdown gracefully. Connect the UPS to a host computer using HPPM, connect the Management Server to an unswitched output receptacle ("UPS R/T2200 INTL rear panel" on page 9, "UPS R/T2200 NA/JPN/TWN rear panel" on the host computer. CAUTION: Use only the computer interface ...
.... CAUTION: Using a USB to serial converter cable will damage the UPS. The software user guide is available for download from the HP website (http://www.hp.com/go /rackandpower) to the host computer. CAUTION: Using a USB to the host computer. Connecting the serial communications port CAUTION:...devices are shutdown gracefully. Connect the UPS to a host computer using HPPM, connect the Management Server to an unswitched output receptacle ("UPS R/T2200 INTL rear panel" on page 9, "UPS R/T2200 NA/JPN/TWN rear panel" on the host computer. CAUTION: Use only the computer interface ...
HP R/T2200 UPS User Guide
Page 23
... not use extension cords. 1. Connect the UPS power cord to charge. Power to the IEC-320-C20 input power receptacle on the UPS rear panel (INTL model only). 2. Connect the input power cord from electric shock or damage to the UPS CAUTION: Do not plug laser printers into a grounded (earthed) electrical...
... not use extension cords. 1. Connect the UPS power cord to charge. Power to the IEC-320-C20 input power receptacle on the UPS rear panel (INTL model only). 2. Connect the input power cord from electric shock or damage to the UPS CAUTION: Do not plug laser printers into a grounded (earthed) electrical...
HP R/T2200 UPS User Guide
Page 24
... will not overload by 100) to all warnings provided in amps, multiply the number of the UPS using the jumper cords included with the UPS (INTL model). Installation 24 After verifying that power is listed in "Precautions (on page 12)." Charging the UPS batteries Allow the batteries to devices. If the...
... will not overload by 100) to all warnings provided in amps, multiply the number of the UPS using the jumper cords included with the UPS (INTL model). Installation 24 After verifying that power is listed in "Precautions (on page 12)." Charging the UPS batteries Allow the batteries to devices. If the...
HP R/T2200 UPS User Guide
Page 31
... is turned clockwise, the UPS becomes more tolerant of rear panel components, see "UPS R/T2200 NA/JPN/TWN rear panel (on page 8)" or "UPS R/T2200 INTL rear panel (on page 9)."
... is turned clockwise, the UPS becomes more tolerant of rear panel components, see "UPS R/T2200 NA/JPN/TWN rear panel (on page 8)" or "UPS R/T2200 INTL rear panel (on page 9)."
HP R/T2200 UPS User Guide
Page 40
UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Utility voltage Available settings frequency (Hz) utility voltage (VAC) 50/60 100, 110, 120* 50/60 220, 230*, 240 Branch circuit rating (A) 20 15 Line ... Nondetachable power cord with NEMA 5-20 plug Detachable power cord with IEC-320-C20 plug UPS output specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Output receptacles 4 x NEMA 5-15R, 4 x NEMA 515/20R 8 x IEC-320-C13 Maximum current 18.3 A 9.5 A Specifications 40 Specifications UPS physical specifications Parameter Height Depth Width Weight Value...
UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Utility voltage Available settings frequency (Hz) utility voltage (VAC) 50/60 100, 110, 120* 50/60 220, 230*, 240 Branch circuit rating (A) 20 15 Line ... Nondetachable power cord with NEMA 5-20 plug Detachable power cord with IEC-320-C20 plug UPS output specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Output receptacles 4 x NEMA 5-15R, 4 x NEMA 515/20R 8 x IEC-320-C13 Maximum current 18.3 A 9.5 A Specifications 40 Specifications UPS physical specifications Parameter Height Depth Width Weight Value...
HP R/T2200 UPS User Guide
Page 41
Power protection specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL VA 2200 2200 Nominal power Nominal voltage rating (W) setting 1600 100, 110, 120 1600 220, 230, 240 Voltage specifications Configuration setting (VAC) 100 110 120 ...
Power protection specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL VA 2200 2200 Nominal power Nominal voltage rating (W) setting 1600 100, 110, 120 1600 220, 230, 240 Voltage specifications Configuration setting (VAC) 100 110 120 ...
HP R/T2200 UPS User Guide
Page 43
Spare parts list Item UPS unit NA UPS unit JPN/TWN UPS unit INTL ERM unit UPS/ERM tower stand UPS/ERM mounting hardware UPS battery Spare part number 410039-001 410040-291 410041-B31 410045-001 410042-001 415694-001 416727-001 Hardware options For information on the supported hardware options, see the HP website (http://www.hp.com/go/rackandpower). To replace parts under warranty, contact an HP authorized service representative. Spares Ordering spares To order a spare, visit the HP website (http://h61003.www6.hp.com). Spares 43
Spare parts list Item UPS unit NA UPS unit JPN/TWN UPS unit INTL ERM unit UPS/ERM tower stand UPS/ERM mounting hardware UPS battery Spare part number 410039-001 410040-291 410041-B31 410045-001 410042-001 415694-001 416727-001 Hardware options For information on the supported hardware options, see the HP website (http://www.hp.com/go/rackandpower). To replace parts under warranty, contact an HP authorized service representative. Spares Ordering spares To order a spare, visit the HP website (http://h61003.www6.hp.com). Spares 43
HP R/T2200 UPS User Guide
Page 54
... 7 power protection specifications 41 power sensitivity adjustment dial, location 8, 9 power sensitivity adjustment dial, setting 30 powering down 31 powering up 24 problem diagnosis 37 R R/T2200 INTL 7, 9 R/T2200 NA/JPN/TWN 7, 8 rack-to-tower conversion 13, 24 rear panel components 8, 9 regulatory compliance identification numbers 46 regulatory compliance notices 46, 48 replacing the...
... 7 power protection specifications 41 power sensitivity adjustment dial, location 8, 9 power sensitivity adjustment dial, setting 30 powering down 31 powering up 24 problem diagnosis 37 R R/T2200 INTL 7, 9 R/T2200 NA/JPN/TWN 7, 8 rack-to-tower conversion 13, 24 rear panel components 8, 9 regulatory compliance identification numbers 46 regulatory compliance notices 46, 48 replacing the...
HP UPS R/T3000 User Guide
Page 59
... voltage frequency (Hz) 50/60 Available settings utility voltage (VAC) 100, 110, 120, 127 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 240 R/T3000 INTL 50/60 200/208, 220, 230, 240 1 The output voltage is 204 for this setting.
... voltage frequency (Hz) 50/60 Available settings utility voltage (VAC) 100, 110, 120, 127 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 240 R/T3000 INTL 50/60 200/208, 220, 230, 240 1 The output voltage is 204 for this setting.
HP UPS R/T3000 User Guide
Page 60
...-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL VA 2880 3300 3300 Nominal power rating (W) 2700 Nominal voltage setting 100, 110, 120, 127 3000 204, 220, 230, 240 3000 204, 220, 230, 240...
...-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL VA 2880 3300 3300 Nominal power rating (W) 2700 Nominal voltage setting 100, 110, 120, 127 3000 204, 220, 230, 240 3000 204, 220, 230, 240...
HP UPS R/T3000 User Guide
Page 63
To replace parts under warranty, contact an HP authorized service representative. UPS spare parts list Item Description 1 UPS unit NA/JPN * UPS unit HV NA/JPN * UPS unit INTL 2 X-slot serial card 3 Battery module * Mounting rails with screws * UPS/ERM mounting brackets * Cord retention clips * Serial download cable * not shown Spare part number 517699-001 517700-001 517701-001 419180-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 63 Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts).
To replace parts under warranty, contact an HP authorized service representative. UPS spare parts list Item Description 1 UPS unit NA/JPN * UPS unit HV NA/JPN * UPS unit INTL 2 X-slot serial card 3 Battery module * Mounting rails with screws * UPS/ERM mounting brackets * Cord retention clips * Serial download cable * not shown Spare part number 517699-001 517700-001 517701-001 419180-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 63 Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts).
HP UPS R/T3000 User Guide
Page 79
R/T3000 INTL 11 R/T3000 models 9 R/T3000 NA 9 R/T3000h JPN 10 R/T3000h NA 10 R/T3000j JPN 9 rack-to-tower conversion 26, 35 rails, installing 14 rear panel connectors 9, ...