HP R/T3000 G2 UPS User Guide
Page 3
Contents Component identification ...7 UPS R/T3000 G2 overview...7 UPS front panel ...7 UPS front panel controls ...8 UPS front panel LED indicators ...8 HP UPS R/T3000 models ...9 R/T3000 NA and R/T3000j JPN rear panel 9 R/T3000h NA and R/T3000h JPN rear panel 10 R/T3000 INT rear panel ...11 REPO port ...11 ERM rear panel...12 Installation ...13 Precautions...13 Preparing to...
Contents Component identification ...7 UPS R/T3000 G2 overview...7 UPS front panel ...7 UPS front panel controls ...8 UPS front panel LED indicators ...8 HP UPS R/T3000 models ...9 R/T3000 NA and R/T3000j JPN rear panel 9 R/T3000h NA and R/T3000h JPN rear panel 10 R/T3000 INT rear panel ...11 REPO port ...11 ERM rear panel...12 Installation ...13 Precautions...13 Preparing to...
HP R/T3000 G2 UPS User Guide
Page 61
... Height Depth Width Weight Value 8.9 cm (3.5 in) 63.5 cm (25 in) 44.5 cm (17.5 in) 45 kg (100 lb) UPS input specifications UPS model R/T3000 NA/JPN Utility voltage frequency (Hz) 50/60 Available settings utility Branch circuit voltage (VAC) rating (A) 100, 110, 120, 127 30 R/T3000h... 200/2081, 220, 230, 20 240 R/T3000 INTL 50/60 200/208, 220, 230, 16 240 1 The output voltage is 204 for this setting. R/T3000h NA/JPN - Line cord Nondetachable power cord with NEMA L5-30 plug Nondetachable power cord with NEMA L6-20 plug Detachable power cord with country-specific plug...
... Height Depth Width Weight Value 8.9 cm (3.5 in) 63.5 cm (25 in) 44.5 cm (17.5 in) 45 kg (100 lb) UPS input specifications UPS model R/T3000 NA/JPN Utility voltage frequency (Hz) 50/60 Available settings utility Branch circuit voltage (VAC) rating (A) 100, 110, 120, 127 30 R/T3000h... 200/2081, 220, 230, 20 240 R/T3000 INTL 50/60 200/208, 220, 230, 16 240 1 The output voltage is 204 for this setting. R/T3000h NA/JPN - Line cord Nondetachable power cord with NEMA L5-30 plug Nondetachable power cord with NEMA L6-20 plug Detachable power cord with country-specific plug...
HP R/T3000 G2 UPS User Guide
Page 62
...-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model VA R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL 2880 / 2400 3300 3300 Nominal power rating (W) 2700 / 2250 3000 3000 Nominal voltage setting 120/100 204 230 Output tolerance specifications Source of...
...-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model VA R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL 2880 / 2400 3300 3300 Nominal power rating (W) 2700 / 2250 3000 3000 Nominal voltage setting 120/100 204 230 Output tolerance specifications Source of...
HP R/T3000 G2 UPS User Guide
Page 64
UPS spare parts list Item Description 1 UPS unit a) NA/JPN b) HV NA/JPN* c) INTL* 2 UPS Network Module 3 Battery module 4 Mounting rails with screws* 5 UPS/ERM mounting brackets* 6 Cord retention clips (6)* 7 Serial download cable* * not shown Spare part number - 638840-001 638841-001 638842-001 636934-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 64 To replace parts under warranty, contact an HP authorized service representative. Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts).
UPS spare parts list Item Description 1 UPS unit a) NA/JPN b) HV NA/JPN* c) INTL* 2 UPS Network Module 3 Battery module 4 Mounting rails with screws* 5 UPS/ERM mounting brackets* 6 Cord retention clips (6)* 7 Serial download cable* * not shown Spare part number - 638840-001 638841-001 638842-001 636934-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 64 To replace parts under warranty, contact an HP authorized service representative. Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts).
HP UPS R/T3000 G2 Installation Instructions
Page 2
... Communications port/option slot • REPO port connector block • Cord retention clips • Rear stabilization brackets (2) and associated hardware • The R/T3000h NA/JPN and R/T3000 INT models ship with: o Two 10 A, 1.83-meter (6-foot) IEC-to-IEC power cords (142263-001), for load equipment power o ...between the UPS communications port and the serial port on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for the specific UPS as a tower" on page 6, "Installing the UPS in the UPS kit. 1. To ...
... Communications port/option slot • REPO port connector block • Cord retention clips • Rear stabilization brackets (2) and associated hardware • The R/T3000h NA/JPN and R/T3000 INT models ship with: o Two 10 A, 1.83-meter (6-foot) IEC-to-IEC power cords (142263-001), for load equipment power o ...between the UPS communications port and the serial port on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for the specific UPS as a tower" on page 6, "Installing the UPS in the UPS kit. 1. To ...
HP UPS R/T3000 Installation Instructions
Page 2
... Readying the equipment 1. If the date on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for the specific UPS as stated in "Input specifications" in a closed or multi-unit rack assembly, the ...Communications port/option slot • REPO port connector block • Cord retention clips • Rear stabilization brackets (2) and associated hardware • The R/T3000h NA/JPN and R/T3000 INT models ship with: o Two 10 A, 1.83-meter (6-foot) IEC-to-IEC power cords (142263-001), for load equipment power o...
... Readying the equipment 1. If the date on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for the specific UPS as stated in "Input specifications" in a closed or multi-unit rack assembly, the ...Communications port/option slot • REPO port connector block • Cord retention clips • Rear stabilization brackets (2) and associated hardware • The R/T3000h NA/JPN and R/T3000 INT models ship with: o Two 10 A, 1.83-meter (6-foot) IEC-to-IEC power cords (142263-001), for load equipment power o...
HP R/T2200 UPS User Guide
Page 3
Contents Component identification ...6 UPS front panel ...6 UPS front panel controls and LED indicators 7 UPS R/T2200 NA/JPN/TWN rear panel...8 UPS R/T2200 INTL rear panel ...9 REPO port ...10 Installation ...12 Precautions...12 Preparing to install the hardware...12 Required tools ...12 Selecting a ...
Contents Component identification ...6 UPS front panel ...6 UPS front panel controls and LED indicators 7 UPS R/T2200 NA/JPN/TWN rear panel...8 UPS R/T2200 INTL rear panel ...9 REPO port ...10 Installation ...12 Precautions...12 Preparing to install the hardware...12 Required tools ...12 Selecting a ...
HP R/T2200 UPS User Guide
Page 8
... maintains the charge on page 30) to charge. • Amber-The batteries are midway through charging. • Green-The batteries are fully charged. UPS R/T2200 NA/JPN/TWN rear panel Component identification 8 IMPORTANT: While in Standby mode until an alternate mode is selected or until utility power is flashing green), the Battery...
... maintains the charge on page 30) to charge. • Amber-The batteries are midway through charging. • Green-The batteries are fully charged. UPS R/T2200 NA/JPN/TWN rear panel Component identification 8 IMPORTANT: While in Standby mode until an alternate mode is selected or until utility power is flashing green), the Battery...
HP R/T2200 UPS User Guide
Page 20
... faster. Output voltage Input voltage range DIP switch 1 DIP switch 2 DIP switch 3 DIP switch 4 R/T2200 120 V* (NA) 108-127 V Up Up Up* Up NA/JPN/TW N 110 V 99-116 V Up Down - - 100 V* 90-106 V Down Up - - (JPN/TWN) 120 V 108-127 V Down Down Down Down R/T2200 INTL 230 V 20-7243 V Up Up Up* Up...
... faster. Output voltage Input voltage range DIP switch 1 DIP switch 2 DIP switch 3 DIP switch 4 R/T2200 120 V* (NA) 108-127 V Up Up Up* Up NA/JPN/TW N 110 V 99-116 V Up Down - - 100 V* 90-106 V Down Up - - (JPN/TWN) 120 V 108-127 V Down Down Down Down R/T2200 INTL 230 V 20-7243 V Up Up Up* Up...
HP R/T2200 UPS User Guide
Page 21
... the UPS to a host computer using HPPM, connect the Management Server to shutdown, ensuring that all connected load devices are shutdown gracefully. Install HP Power Manager software 4.1 or later on page 8), and then set the Management Server as the last device to an unswitched output receptacle ("UPS ...R/T2200 INTL rear panel" on page 9, "UPS R/T2200 NA/JPN/TWN rear panel" on the host computer. CAUTION: Using a USB to the host computer. IMPORTANT: If using either the USB cable or the ...
... the UPS to a host computer using HPPM, connect the Management Server to shutdown, ensuring that all connected load devices are shutdown gracefully. Install HP Power Manager software 4.1 or later on page 8), and then set the Management Server as the last device to an unswitched output receptacle ("UPS ...R/T2200 INTL rear panel" on page 9, "UPS R/T2200 NA/JPN/TWN rear panel" on the host computer. CAUTION: Using a USB to the host computer. IMPORTANT: If using either the USB cable or the ...
HP R/T2200 UPS User Guide
Page 24
... devices, verify that the UPS will not overload: • Connect the device power cords to the output receptacles on the rear panel of the UPS (NA/JPN/TWN model). -or- • Connect devices to all warnings provided in amps, multiply the number of amps by 120 (for at the UPS output receptacles...
... devices, verify that the UPS will not overload: • Connect the device power cords to the output receptacles on the rear panel of the UPS (NA/JPN/TWN model). -or- • Connect devices to all warnings provided in amps, multiply the number of amps by 120 (for at the UPS output receptacles...
HP R/T2200 UPS User Guide
Page 31
... devices. 2. Disconnect the UPS from utility power. 4. As the dial is turned clockwise, the UPS becomes more tolerant of rear panel components, see "UPS R/T2200 NA/JPN/TWN rear panel (on page 8)" or "UPS R/T2200 INTL rear panel (on page 9)." Press the Power On/Standby button. Power to discharge. UPS operations 31...
... devices. 2. Disconnect the UPS from utility power. 4. As the dial is turned clockwise, the UPS becomes more tolerant of rear panel components, see "UPS R/T2200 NA/JPN/TWN rear panel (on page 8)" or "UPS R/T2200 INTL rear panel (on page 9)." Press the Power On/Standby button. Power to discharge. UPS operations 31...
HP R/T2200 UPS User Guide
Page 40
... (A) 20 15 Line cord Nondetachable power cord with NEMA 5-20 plug Detachable power cord with IEC-320-C20 plug UPS output specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Output receptacles 4 x NEMA 5-15R, 4 x NEMA 515/20R 8 x IEC-320-C13 Maximum current 18.3 A 9.5 A Specifications 40 Specifications UPS physical specifications Parameter Height Depth...
... (A) 20 15 Line cord Nondetachable power cord with NEMA 5-20 plug Detachable power cord with IEC-320-C20 plug UPS output specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL Output receptacles 4 x NEMA 5-15R, 4 x NEMA 515/20R 8 x IEC-320-C13 Maximum current 18.3 A 9.5 A Specifications 40 Specifications UPS physical specifications Parameter Height Depth...
HP R/T2200 UPS User Guide
Page 41
Power protection specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL VA 2200 2200 Nominal power Nominal voltage rating (W) setting 1600 100, 110, 120 1600 220, 230, 240 Voltage specifications Configuration setting (VAC) ...
Power protection specifications UPS model R/T2200 NA/JPN/TWN R/T2200 INTL VA 2200 2200 Nominal power Nominal voltage rating (W) setting 1600 100, 110, 120 1600 220, 230, 240 Voltage specifications Configuration setting (VAC) ...
HP R/T2200 UPS User Guide
Page 54
... specifications 41 power sensitivity adjustment dial, location 8, 9 power sensitivity adjustment dial, setting 30 powering down 31 powering up 24 problem diagnosis 37 R R/T2200 INTL 7, 9 R/T2200 NA/JPN/TWN 7, 8 rack-to-tower conversion 13, 24 rear panel components 8, 9 regulatory compliance identification numbers 46 regulatory compliance notices 46, 48 replacing the batteries 33, 34...
... specifications 41 power sensitivity adjustment dial, location 8, 9 power sensitivity adjustment dial, setting 30 powering down 31 powering up 24 problem diagnosis 37 R R/T2200 INTL 7, 9 R/T2200 NA/JPN/TWN 7, 8 rack-to-tower conversion 13, 24 rear panel components 8, 9 regulatory compliance identification numbers 46 regulatory compliance notices 46, 48 replacing the batteries 33, 34...
HP UPS R/T3000 User Guide
Page 59
....5 cm (25 in) 44.5 cm (17.5 in) 55 kg (122 lb) UPS input specifications UPS model R/T3000 NA/JPN Utility voltage frequency (Hz) 50/60 Available settings utility voltage (VAC) 100, 110, 120, 127 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 240 R/T3000 INTL 50/60 200/208, 220, 230, 240 1 The... NEMA L5-30 plug Nondetachable power cord with NEMA L6-20 plug Detachable power cord with country-specific plug UPS output specifications UPS model R/T3000 NA/JPN Load segment 1 Output receptacles 2 x 5-20T 1 x L5-30R Specifications 59
....5 cm (25 in) 44.5 cm (17.5 in) 55 kg (122 lb) UPS input specifications UPS model R/T3000 NA/JPN Utility voltage frequency (Hz) 50/60 Available settings utility voltage (VAC) 100, 110, 120, 127 R/T3000h NA/JPN 50/60 200/2081, 220, 230, 240 R/T3000 INTL 50/60 200/208, 220, 230, 240 1 The... NEMA L5-30 plug Nondetachable power cord with NEMA L6-20 plug Detachable power cord with country-specific plug UPS output specifications UPS model R/T3000 NA/JPN Load segment 1 Output receptacles 2 x 5-20T 1 x L5-30R Specifications 59
HP UPS R/T3000 User Guide
Page 60
... 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL VA 2880 3300 3300 Nominal power rating (W) 2700 Nominal voltage setting 100, 110, 120, 127 3000 204, 220, 230, 240 3000 204, 220...
... 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 3 x IEC-320-C13 1 x IEC-320-C19 Power protection specifications UPS model R/T3000 NA/JPN R/T3000h NA/JPN R/T3000 INTL VA 2880 3300 3300 Nominal power rating (W) 2700 Nominal voltage setting 100, 110, 120, 127 3000 204, 220, 230, 240 3000 204, 220...
HP UPS R/T3000 User Guide
Page 63
UPS spare parts list Item Description 1 UPS unit NA/JPN * UPS unit HV NA/JPN * UPS unit INTL 2 X-slot serial card 3 Battery module * Mounting rails with screws * UPS/ERM mounting brackets * Cord retention clips * Serial download cable * not shown Spare part number 517699-001 517700-001 517701-001 419180-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 63 Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). To replace parts under warranty, contact an HP authorized service representative.
UPS spare parts list Item Description 1 UPS unit NA/JPN * UPS unit HV NA/JPN * UPS unit INTL 2 X-slot serial card 3 Battery module * Mounting rails with screws * UPS/ERM mounting brackets * Cord retention clips * Serial download cable * not shown Spare part number 517699-001 517700-001 517701-001 419180-001 517703-001 419181-001 582931-001 407409-001 397642-001 Spares 63 Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). To replace parts under warranty, contact an HP authorized service representative.
HP R/T2200 UPS Installation Instructions
Page 5
... the default setting. Down Down Down Down 127 V R/T2200 INTL 230 V 20- Down Up - - 233 V 240 V 216- Install HP Power Manager software 4.1 or later on the rear panel of the position. IMPORTANT: Power management software requires the communications port to be appropriately cabled ... without an ERM connected. Output voltage Input DIP DIP DIP DIP voltage switch switch switch switch range 1 2 3 4 R/T2200 120 V* NA/JPN/TWN (NA) 108- Down Up - - (JPN/TWN) 106 V 120 V 108- CAUTION: Using a USB to the host computer. Selecting the UPS voltage configuration Using a small tool,...
... the default setting. Down Down Down Down 127 V R/T2200 INTL 230 V 20- Down Up - - 233 V 240 V 216- Install HP Power Manager software 4.1 or later on the rear panel of the position. IMPORTANT: Power management software requires the communications port to be appropriately cabled ... without an ERM connected. Output voltage Input DIP DIP DIP DIP voltage switch switch switch switch range 1 2 3 4 R/T2200 120 V* NA/JPN/TWN (NA) 108- Down Up - - (JPN/TWN) 106 V 120 V 108- CAUTION: Using a USB to the host computer. Selecting the UPS voltage configuration Using a small tool,...
HP R/T2200 UPS Installation Instructions
Page 6
.... After verifying that the UPS will not overload: • Connect the device power cords to the output receptacles on the rear panel of the UPS (NA/JPN/TWN model). -or• Connect devices to the output receptacles on the UPS rear panel (INTL model only). 2. Connecting the REPO port WARNING: To meet...
.... After verifying that the UPS will not overload: • Connect the device power cords to the output receptacles on the rear panel of the UPS (NA/JPN/TWN model). -or• Connect devices to the output receptacles on the UPS rear panel (INTL model only). 2. Connecting the REPO port WARNING: To meet...