Specifications
Page 6
... 7.7. Ultra DMA timings...47 7.9.1 Initiating Read DMA 47 7.9.2 Host Pausing Read DMA 48 Travelstar 5K100 Hard Disk Drive Specification ii Signal definitions ...40 7.4. Signal descriptions...41 7.5. Mechanical specifications 30 6.4.1 Physical dimensions and weight 30 6.4.2 Mounting hole locations 31 6.4.3 Connector and jumper description 31 6.4.4 Mounting orientation 31 6.4.5 Load/unload mechanism 32 6.5. Interface logic signal levels 44...
... 7.7. Ultra DMA timings...47 7.9.1 Initiating Read DMA 47 7.9.2 Host Pausing Read DMA 48 Travelstar 5K100 Hard Disk Drive Specification ii Signal definitions ...40 7.4. Signal descriptions...41 7.5. Mechanical specifications 30 6.4.1 Physical dimensions and weight 30 6.4.2 Mounting hole locations 31 6.4.3 Connector and jumper description 31 6.4.4 Mounting orientation 31 6.4.5 Load/unload mechanism 32 6.5. Interface logic signal levels 44...
Specifications
Page 45
.... The recommended mounting screw torque is operated in the other permissible orientations from these positions. Travelstar 5K100 Hard Disk Drive Specification 31 The jumper setting method is described in Section 7.10, "Drive address setting" on page 39. 6.4.4 Mounting orientation The drive will operate in all axes (six directions) and will stay within specification limits if the...
.... The recommended mounting screw torque is operated in the other permissible orientations from these positions. Travelstar 5K100 Hard Disk Drive Specification 31 The jumper setting method is described in Section 7.10, "Drive address setting" on page 39. 6.4.4 Mounting orientation The drive will operate in all axes (six directions) and will stay within specification limits if the...
Specifications
Page 50
...Travelstar 5K100 Hard Disk Drive Specification 36 6.7 Identification labels The following labels are affixed to be designated in the drawing provided by the user. • Labels containing the vendor's name, disk drive model number, serial number, place of manufacture, and UL/ CSA logos. • Labels containing jumper information if required by Hitachi...with a random accessing routine at the maximum data rate, the drive meets the worldwide EMC requirements listed below . The regulation for certification of Hitachi products • EU EMC Directive, Technical Requirements and Conformity ...
...Travelstar 5K100 Hard Disk Drive Specification 36 6.7 Identification labels The following labels are affixed to be designated in the drawing provided by the user. • Labels containing the vendor's name, disk drive model number, serial number, place of manufacture, and UL/ CSA logos. • Labels containing jumper information if required by Hitachi...with a random accessing routine at the maximum data rate, the drive meets the worldwide EMC requirements listed below . The regulation for certification of Hitachi products • EU EMC Directive, Technical Requirements and Conformity ...
Specifications
Page 56
...Travelstar 5K100 Hard Disk Drive Specification 42 shall maintain VoH and VoL compatibility, given the IoH and IoL requirements of a valid Execute Drive Diagnostics command, device 1 shall negate PDIAG- The signal level may assert DASP- PDIAGThis signal shall be different from the receipt of CSEL to one drive ...should clear BSY before asserting PDIAG-, as a Slave. CSEL (Cable Select) This signal is monitored to determine the drive address (master or slave) when the jumper on the same AT interface cable to avoid master-master...
...Travelstar 5K100 Hard Disk Drive Specification 42 shall maintain VoH and VoL compatibility, given the IoH and IoL requirements of a valid Execute Drive Diagnostics command, device 1 shall negate PDIAG- The signal level may assert DASP- PDIAGThis signal shall be different from the receipt of CSEL to one drive ...should clear BSY before asserting PDIAG-, as a Slave. CSEL (Cable Select) This signal is monitored to determine the drive address (master or slave) when the jumper on the same AT interface cable to avoid master-master...
Specifications
Page 69
... pin 28 of a jumper. 31 42 1 2 3 4 5 Setting 1-Device 0 (Master) (no jumper is Setting 1 (no jumper). Three drive addresses are shown below. If pin 28 is open (or logic high), the drive is a Master. When the drive address is Cable Select, the address depends on the interface connector determines the drive address. Travelstar 5K100 Hard Disk Drive Specification 55 Two addresses...
... pin 28 of a jumper. 31 42 1 2 3 4 5 Setting 1-Device 0 (Master) (no jumper is Setting 1 (no jumper). Three drive addresses are shown below. If pin 28 is open (or logic high), the drive is a Master. When the drive address is Cable Select, the address depends on the interface connector determines the drive address. Travelstar 5K100 Hard Disk Drive Specification 55 Two addresses...
Specifications
Page 131
... level 15- 8(=40h) Reserved 7- 0(=xxh) Current Advanced Power Management level set Note 1. above ViH 0=Device detected CBLID- Travelstar 5K100 Hard Disk Drive Specification 117 Table 76: Identify device information. (Part 6 of cylinders/heads/sectors by Set Features Command (01h to 0 7(=0)... bits to 0 12(=0) Reserved 11(=X) 1=Device 1 passed diagnostic 10-9(=X) How Device 1 determined the device number: 00= Reserved 01= a jumper was used 10= the CSEL signal was used 11=some other method used or method unknown 8(=1) Always 7- 0 Device 0 hardware reset result Device...
... level 15- 8(=40h) Reserved 7- 0(=xxh) Current Advanced Power Management level set Note 1. above ViH 0=Device detected CBLID- Travelstar 5K100 Hard Disk Drive Specification 117 Table 76: Identify device information. (Part 6 of cylinders/heads/sectors by Set Features Command (01h to 0 7(=0)... bits to 0 12(=0) Reserved 11(=X) 1=Device 1 passed diagnostic 10-9(=X) How Device 1 determined the device number: 00= Reserved 01= a jumper was used 10= the CSEL signal was used 11=some other method used or method unknown 8(=1) Always 7- 0 Device 0 hardware reset result Device...