... antimicrobial which helps "wash the air as the water level decreases in the filter for its life and that passes through the humidifier and the QuietCare™ fan blows out invisible, moisture- This technology reduces the likelihood of unsightly ... clog or discolor the filter, affecting its life - approximately 1-3 months*. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 2 HOW IT WORKS HCM-300T HCM-310T / HCM-315T Quiet Care Technology - Protec™ Antimicrobial Treated Filter - The UV germicidal bulb located inside the filter. Bacteria: Escheria Coli ...
... antimicrobial which helps "wash the air as the water level decreases in the filter for its life and that passes through the humidifier and the QuietCare™ fan blows out invisible, moisture- This technology reduces the likelihood of unsightly ... clog or discolor the filter, affecting its life - approximately 1-3 months*. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 2 HOW IT WORKS HCM-300T HCM-310T / HCM-315T Quiet Care Technology - Protec™ Antimicrobial Treated Filter - The UV germicidal bulb located inside the filter. Bacteria: Escheria Coli ...
Owners Manual
Page 3
See CLEANING Instructions. 3 HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 3 SETTING UP YOUR HUMIDIFIER Your humidifier is made up of these parts: WATER TANK SEAL PAD TANK CAP FILTER TRAY MAIN HOUSING HCM-310T / HCM-315T HCM-300T It is recommended that you disinfect your humidifier prior to first use.
See CLEANING Instructions. 3 HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 3 SETTING UP YOUR HUMIDIFIER Your humidifier is made up of these parts: WATER TANK SEAL PAD TANK CAP FILTER TRAY MAIN HOUSING HCM-310T / HCM-315T HCM-300T It is recommended that you disinfect your humidifier prior to first use.
Owners Manual
Page 4
...4 Doing so could cause leakage and spills. it will not accept responsibility for proper airflow. Replace tank cap. Step 1 Remove the filter from any walls for property damage caused by turning counterclockwise . Step 2 Step 3 Power Turn tank upside-down. With the power switch...Place tank back on a waterresistant surface, as water can damage furniture and some flooring. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 4 SETTING UP YOUR HUMIDIFIER (CONT'D) Placement Step 1 Soak Filter Step 1 Select a firm, level location at least 6" (15cm) from the holding basket...
...4 Doing so could cause leakage and spills. it will not accept responsibility for proper airflow. Replace tank cap. Step 1 Remove the filter from any walls for property damage caused by turning counterclockwise . Step 2 Step 3 Power Turn tank upside-down. With the power switch...Place tank back on a waterresistant surface, as water can damage furniture and some flooring. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 4 SETTING UP YOUR HUMIDIFIER (CONT'D) Placement Step 1 Soak Filter Step 1 Select a firm, level location at least 6" (15cm) from the holding basket...
Owners Manual
Page 6
... water tank. Remove water tank from the unit. Insert new filter into holding basket and place filter holding basket and discard old filter. It is recommended that of the humidifier. To change your other hand to pull the UV cartridge away from unit before moving. Do not squeeze out. To...Keep in the kitchen or bathroom on your humidifier. 6 Remove the water tank and carefully set aside. CHANGING THE UV BULB The UV bulb will operate for an average output of the UV bulb. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 6 NOTE: It is recommended you change the...
... water tank. Remove water tank from the unit. Insert new filter into holding basket and place filter holding basket and discard old filter. It is recommended that of the humidifier. To change your other hand to pull the UV cartridge away from unit before moving. Do not squeeze out. To...Keep in the kitchen or bathroom on your humidifier. 6 Remove the water tank and carefully set aside. CHANGING THE UV BULB The UV bulb will operate for an average output of the UV bulb. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 6 NOTE: It is recommended you change the...
Owners Manual
Page 7
... back of the basket with a soft cloth or brush. NOTE: REMOVE FILTER BEFORE CLEANING. Failure to do so will destroy the filter. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 7 CHANGING THE UV BULB (CONT'D.) Step 4 Step 5 Step 6 Place your humidifier. Place filter basket and replace the water tank in the proper order to...
... back of the basket with a soft cloth or brush. NOTE: REMOVE FILTER BEFORE CLEANING. Failure to do so will destroy the filter. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 7 CHANGING THE UV BULB (CONT'D.) Step 4 Step 5 Step 6 Place your humidifier. Place filter basket and replace the water tank in the proper order to...
Owners Manual
Page 8
...completely before storing. of household bleach and 1 gallon of the filter or damage the humidifier, thereby hindering the humidifier's effectiveness. DO NOT store with a used for 20 the filter basket. do so will not be sure to specify model number. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 8 CLEANING... Step 6 Pour some solution into Let stand for at least one week or more, or at : www.kaz.com Purchase replacement filter part number HAC-504AW or HAC-504 and UV bulb part number 22LP300T000. 8 Step 7 Rinse with 1 tsp. Call us toll-free at: 1-800-477-0457; basket. CONSUMER...
...completely before storing. of household bleach and 1 gallon of the filter or damage the humidifier, thereby hindering the humidifier's effectiveness. DO NOT store with a used for 20 the filter basket. do so will not be sure to specify model number. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 8 CLEANING... Step 6 Pour some solution into Let stand for at least one week or more, or at : www.kaz.com Purchase replacement filter part number HAC-504AW or HAC-504 and UV bulb part number 22LP300T000. 8 Step 7 Rinse with 1 tsp. Call us toll-free at: 1-800-477-0457; basket. CONSUMER...
Owners Manual
Page 9
... the water level in the tank decreasing. If the humidity level is over 30 days, follow the cleaning instructions. 9 Q: The Advanced Mist™ Humidistat knob was set according to the manual, but will not affect the humidifier's performance. Is something wrong? (Model...Moving the knob clockwise to help break up deposits. Soak filter in the Base. When operating normally you notice a decrease in color indicates only a mineral deposit. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 9 ELECTRICAL RATINGS The Honeywell QuietCare™ Series models are on . Since your air is...
... the water level in the tank decreasing. If the humidity level is over 30 days, follow the cleaning instructions. 9 Q: The Advanced Mist™ Humidistat knob was set according to the manual, but will not affect the humidifier's performance. Is something wrong? (Model...Moving the knob clockwise to help break up deposits. Soak filter in the Base. When operating normally you notice a decrease in color indicates only a mineral deposit. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 9 ELECTRICAL RATINGS The Honeywell QuietCare™ Series models are on . Since your air is...
Owners Manual
Page 10
This warranty does not apply to the filter or Protec™ Cleaning Cartridge. Please include your name, address and a daytime phone number. You must prepay shipping charges. Include proof of normal wear and ... LIABLE FOR INCIDENTAL OR : CONSEQUENTIAL DAMAGES OF ANY NATURE. In Canada: Kaz, Incorporated Attn: Returns Department 510 Bronte Street South Milton, ON L9T 2X6 Canada B. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 10 3 YEAR LIMITED WARRANTY You should be defective in material or workmanship. Defects that are the result...
This warranty does not apply to the filter or Protec™ Cleaning Cartridge. Please include your name, address and a daytime phone number. You must prepay shipping charges. Include proof of normal wear and ... LIABLE FOR INCIDENTAL OR : CONSEQUENTIAL DAMAGES OF ANY NATURE. In Canada: Kaz, Incorporated Attn: Returns Department 510 Bronte Street South Milton, ON L9T 2X6 Canada B. HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 10 3 YEAR LIMITED WARRANTY You should be defective in material or workmanship. Defects that are the result...