Owners Guide
Page 4
... CAUTIONS BEFORE USING YOUR UV SYSTEM WARNING UV Light Hazard. Can cause temporary or permanent loss of heating and air conditioning system. To prevent exposure to ultraviolet light, disconnect power to Ultraviolet System before servicing any part of vision. CAUTION Personal Injury Hazard. Disconnect power 15 minutes before cleaning or replacing ultraviolet bulb(s). Do not attempt to...
... CAUTIONS BEFORE USING YOUR UV SYSTEM WARNING UV Light Hazard. Can cause temporary or permanent loss of heating and air conditioning system. To prevent exposure to ultraviolet light, disconnect power to Ultraviolet System before servicing any part of vision. CAUTION Personal Injury Hazard. Disconnect power 15 minutes before cleaning or replacing ultraviolet bulb(s). Do not attempt to...
Owners Guide
Page 6
... reset button for 30 minutes (Surface Treatment System). Cycling power does not reset the internal timers. LAMP LIGHT INDICATOR LED CHANGE INDICATOR RESET BUTTON M22856 Fig. 3. See Fig. 3. Do not attempt to operate until catastrophic bulb failure (bulb burns out) but the kill ...to 11% bulb lifea remaining Nothing Flashing 10 to 1% bulb lifea remaining Purchases bulb(s) Solid 0% bulb lifea remaining Replaces bulb(s) aBulb life means emitting adequate amount of UV-C energy to maintain an effective kill rate. This brings the lamp on for 40 minutes (Air Treatment System) or ...
... reset button for 30 minutes (Surface Treatment System). Cycling power does not reset the internal timers. LAMP LIGHT INDICATOR LED CHANGE INDICATOR RESET BUTTON M22856 Fig. 3. See Fig. 3. Do not attempt to operate until catastrophic bulb failure (bulb burns out) but the kill ...to 11% bulb lifea remaining Nothing Flashing 10 to 1% bulb lifea remaining Purchases bulb(s) Solid 0% bulb lifea remaining Replaces bulb(s) aBulb life means emitting adequate amount of UV-C energy to maintain an effective kill rate. This brings the lamp on for 40 minutes (Air Treatment System) or ...
Owners Guide
Page 7
.... UV bulb cleaning reminder schedule. To clean your UV System and allow the bulb to cool for at least 15 minutes. 7 69-1573-3 UV BULB CLEANING REMINDER SCHEDULE INSTALLATION DATE: (month) , (year) YEAR J F M A M J J A S O N D M13516A Fig. 4. UV100E ULTRAVIOLET SYSTEM HOW YOU CAN MAINTAIN YOUR UV SYSTEM You should regularly clean your UV System to maintain peak effectiveness of your air treatment or surface treatment system. Replace the ultraviolet bulb...
.... UV bulb cleaning reminder schedule. To clean your UV System and allow the bulb to cool for at least 15 minutes. 7 69-1573-3 UV BULB CLEANING REMINDER SCHEDULE INSTALLATION DATE: (month) , (year) YEAR J F M A M J J A S O N D M13516A Fig. 4. UV100E ULTRAVIOLET SYSTEM HOW YOU CAN MAINTAIN YOUR UV SYSTEM You should regularly clean your UV System to maintain peak effectiveness of your air treatment or surface treatment system. Replace the ultraviolet bulb...
Owners Guide
Page 10
... wait ten minutes for your UV System and allow the bulb to cool for the airflow sensor to your heating and cooling system. During this occurs, remove power to your unit. Unit Description Replacement Bulb/ Handle Assembly SnapLamp™ Replacement Bulb UV100E1043 Air Treatment System UC100E1006 UC18W1004 UV100E2009 Air Treatment System UC100E1030 (two needed) UC36W1006 (two needed) UV100E3007 UC100E1030 Surface Treatment System UC36W1006 2. Unplug or turn...
... wait ten minutes for your UV System and allow the bulb to cool for the airflow sensor to your heating and cooling system. During this occurs, remove power to your unit. Unit Description Replacement Bulb/ Handle Assembly SnapLamp™ Replacement Bulb UV100E1043 Air Treatment System UC100E1006 UC18W1004 UV100E2009 Air Treatment System UC100E1030 (two needed) UC36W1006 (two needed) UV100E3007 UC100E1030 Surface Treatment System UC36W1006 2. Unplug or turn...
Owners Guide
Page 11
... 5 and 6; Disconnect lamp glass from SnapLamp™ handle. 6. Replace lamp glass in the other and pull straight apart. Insert the bulb into the base. See Fig. 9. 9. For UV Air Treatment Systems, wait ten minutes for five seconds to calibrate. During this occurs, remove power to your UV System. 10. If this time, the furnace fan must remain...
... 5 and 6; Disconnect lamp glass from SnapLamp™ handle. 6. Replace lamp glass in the other and pull straight apart. Insert the bulb into the base. See Fig. 9. 9. For UV Air Treatment Systems, wait ten minutes for five seconds to calibrate. During this occurs, remove power to your UV System. 10. If this time, the furnace fan must remain...
Owners Guide
Page 12
... any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at any questions concerning this warranty, please write Honeywell Customer Relations, Honeywell, 1985 Douglas Dr. N MN10-1461, Golden Valley, MN 55422. Some... ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario, M1V4Z9. UV100E ULTRAVIOLET SYSTEM Five-Year Limited Warranty Honeywell warrants this product, excluding bulbs, to be to repair or replace the product within a reasonable period of time. If, at Honeywell's option) within...
... any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at any questions concerning this warranty, please write Honeywell Customer Relations, Honeywell, 1985 Douglas Dr. N MN10-1461, Golden Valley, MN 55422. Some... ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario, M1V4Z9. UV100E ULTRAVIOLET SYSTEM Five-Year Limited Warranty Honeywell warrants this product, excluding bulbs, to be to repair or replace the product within a reasonable period of time. If, at Honeywell's option) within...