Page 10
... CONTENTS ■ Fuse replacement 13-7 ■ Resetting the CPU 13-7 ■ About protection indications 13-8 ■ Screen saver function 13-8 Section 14 CONTROL COMMAND ■ Remote jack (CI-V) information 14-2 D CI-V connection example 14-2 D Data format 14-2 D Command table 14-3 D To send/read memory contents 14-9 D Band stacking register 14-9 D Codes...
... CONTENTS ■ Fuse replacement 13-7 ■ Resetting the CPU 13-7 ■ About protection indications 13-8 ■ Screen saver function 13-8 Section 14 CONTROL COMMAND ■ Remote jack (CI-V) information 14-2 D CI-V connection example 14-2 D Data format 14-2 D Command table 14-3 D To send/read memory contents 14-9 D Band stacking register 14-9 D Codes...
Instruction Manual
Page 22
...electrical shocks, TVI, BCI and other problems. y CIRCUIT BREAKER Cuts off the AC input when over-current occurs. o CI-V REMOTE CONTROL JACK [REMOTE] (pgs. 2-6, 14-2) ➥ Connects a PC via the optional CT-17 CI-V LEVEL CONVERTER for external control of ... r ANTENNA CONNECTOR 4 [ANT 4] (p. 2-5) Accept a 50 Ω antenna with another Icom CI-V transceiver or receiver. !0 RS-232C TERMINAL [RS-232C] (p. 2-6) Connects an RS-232C cable, D-sub 9-pin to connect the IC-7700 to remotely control the IC-7700 without the optional CT-17, or for transceive operation with a PL-259 plug connector.
...electrical shocks, TVI, BCI and other problems. y CIRCUIT BREAKER Cuts off the AC input when over-current occurs. o CI-V REMOTE CONTROL JACK [REMOTE] (pgs. 2-6, 14-2) ➥ Connects a PC via the optional CT-17 CI-V LEVEL CONVERTER for external control of ... r ANTENNA CONNECTOR 4 [ANT 4] (p. 2-5) Accept a 50 Ω antenna with another Icom CI-V transceiver or receiver. !0 RS-232C TERMINAL [RS-232C] (p. 2-6) Connects an RS-232C cable, D-sub 9-pin to connect the IC-7700 to remotely control the IC-7700 without the optional CT-17, or for transceive operation with a PL-259 plug connector.
Instruction Manual
Page 31
2 INSTALLATION AND CONNECTIONS ■ Required connections D Front panel CW key Connects an electronic keyer. DISPL AY 15A GND REMOTE RS-232C AC I /O 10MHz -10dBm Antenna 1, 2, 3, 4 (p. 2-4) [Example]: ANT1 for 1.8-18 MHz bands, ANT 2 for 21-28 MHz bands ANT3 for 50 MHz band, ANT 4 for ...
2 INSTALLATION AND CONNECTIONS ■ Required connections D Front panel CW key Connects an electronic keyer. DISPL AY 15A GND REMOTE RS-232C AC I /O 10MHz -10dBm Antenna 1, 2, 3, 4 (p. 2-4) [Example]: ANT1 for 1.8-18 MHz bands, ANT 2 for 21-28 MHz bands ANT3 for 50 MHz band, ANT 4 for ...
Instruction Manual
Page 32
... can also be activated in the antenna set screen (p.10-5). ANT 1 ANT 2 ANT 3 ANT 4 E X T- DISPL AY 15A GND REMOTE RS-232C AC I /O 10MHz -10dBm RX ANT IN/OUT Connects an external preamp or lowpass filter. SP ACC 2 1 RELAY ALC ALC ADJ...COMP MONI GAIN VOX GAIN D Rear panel- 1 Antenna 1, 2, 3, 4 (p. 2-8) Connects a linear amplifier, antenna selector, etc. [X-VERTER] Connects a transverter for V/UHF band use. [REMOTE], [RS-232C] (p. 14-2) Used for RTTY/PSK31 operation, as well as other text edit operations. External speaker (p. 15-4) SP-20 (option) 2-6 [RELAY], [ALC] (p. 2-8) ...
... can also be activated in the antenna set screen (p.10-5). ANT 1 ANT 2 ANT 3 ANT 4 E X T- DISPL AY 15A GND REMOTE RS-232C AC I /O 10MHz -10dBm RX ANT IN/OUT Connects an external preamp or lowpass filter. SP ACC 2 1 RELAY ALC ALC ADJ...COMP MONI GAIN VOX GAIN D Rear panel- 1 Antenna 1, 2, 3, 4 (p. 2-8) Connects a linear amplifier, antenna selector, etc. [X-VERTER] Connects a transverter for V/UHF band use. [REMOTE], [RS-232C] (p. 14-2) Used for RTTY/PSK31 operation, as well as other text edit operations. External speaker (p. 15-4) SP-20 (option) 2-6 [RELAY], [ALC] (p. 2-8) ...
Instruction Manual
Page 33
... for external equipment power supply. (max. 1 A capacity) External keypad Connects an external keypad for direct voice memory and memory keyer controls. DISPL AY 15A GND REMOTE RS-232C AC I /O 10MHz -10dBm [METER] Connects an external meter, etc. 3.5 (d) mm; 1⁄8″ plug [S/P DIF IN/OUT] Connects a PC for the CPU firmware update...
... for external equipment power supply. (max. 1 A capacity) External keypad Connects an external keypad for direct voice memory and memory keyer controls. DISPL AY 15A GND REMOTE RS-232C AC I /O 10MHz -10dBm [METER] Connects an external meter, etc. 3.5 (d) mm; 1⁄8″ plug [S/P DIF IN/OUT] Connects a PC for the CPU firmware update...
Instruction Manual
Page 34
... "MOSFET" setting (see p. 12-8 for details). Connect [INPUT2] if necessary Coaxial cable* REMOTE EXCITER 1 1&2 GND ANT1 ANT2 GND ACC 2 IC-PW1/EURO AC outlet Ground (Non-European versions: 100-120/220-240 V European version : 230 V) Transceiver *Optional D Connecting a non-Icom linear amplifier To an antenna ANT1 50 Ω RELAY coaxial cable Transceiver ALC...
... "MOSFET" setting (see p. 12-8 for details). Connect [INPUT2] if necessary Coaxial cable* REMOTE EXCITER 1 1&2 GND ANT1 ANT2 GND ACC 2 IC-PW1/EURO AC outlet Ground (Non-European versions: 100-120/220-240 V European version : 230 V) Transceiver *Optional D Connecting a non-Icom linear amplifier To an antenna ANT1 50 Ω RELAY coaxial cable Transceiver ALC...
Instruction Manual
Page 189
CONTROL COMMAND Section 14 ■ Remote jack (CI-V) information 14-2 D CI-V connection example 14-2 D Data format 14-2 D Command table 14-3 D To send/read memory contents 14-9 D Band stacking register 14-9 D Codes ...
CONTROL COMMAND Section 14 ■ Remote jack (CI-V) information 14-2 D CI-V connection example 14-2 D Data format 14-2 D Command table 14-3 D To send/read memory contents 14-9 D Band stacking register 14-9 D Codes ...
Instruction Manual
Page 190
... D Data format Controller to command numbers. 14 CONTROL COMMAND ■ Remote jack (CI-V) information D CI-V connection example IC-7700 9-15 V DC The transceiver can be connected through an optional CT-17 CI-V LEVEL CONVERTER to controller 14-2 The Icom Communications Interface-V (CI-V) controls the transceiver. OK message to controller u...frequency or memory number entry End of message code (fixed) (fixed) FE FE E0 74 Cn Sc Data area FD q w ert y u IC-7700 to controller FE FE E0 74 FA FD NG message to a PC equipped with an RS-232C port. See p. 12-17 for some commands....
... D Data format Controller to command numbers. 14 CONTROL COMMAND ■ Remote jack (CI-V) information D CI-V connection example IC-7700 9-15 V DC The transceiver can be connected through an optional CT-17 CI-V LEVEL CONVERTER to controller 14-2 The Icom Communications Interface-V (CI-V) controls the transceiver. OK message to controller u...frequency or memory number entry End of message code (fixed) (fixed) FE FE E0 74 Cn Sc Data area FD q w ert y u IC-7700 to controller FE FE E0 74 FA FD NG message to a PC equipped with an RS-232C port. See p. 12-17 for some commands....
Instruction Manual
Page 202
... break-in (QSK) operation. input power : 5 W Hand microphone equipped with an Icom transceiver. Includes [UP]/[DOWN] switches, low (bass) cut switch and mic gain control...• Input impedance : 8 Ω • Max. The amplifier/power supply unit and the remote control unit can connect to the serial CI-V data. You can be separately installed. • SM-20 DESKTOP...can be used with [UP]/[DOWN] switches. 15-4 15 SPECIFICATIONS AND OPTIONS ■ Options • IC-PW1/EURO HF/50 MHz ALL BAND 1 kW LINEAR AMPLIFIER Full-duty-cycle 1 kW linear amplifier including...
... break-in (QSK) operation. input power : 5 W Hand microphone equipped with an Icom transceiver. Includes [UP]/[DOWN] switches, low (bass) cut switch and mic gain control...• Input impedance : 8 Ω • Max. The amplifier/power supply unit and the remote control unit can connect to the serial CI-V data. You can be separately installed. • SM-20 DESKTOP...can be used with [UP]/[DOWN] switches. 15-4 15 SPECIFICATIONS AND OPTIONS ■ Options • IC-PW1/EURO HF/50 MHz ALL BAND 1 kW LINEAR AMPLIFIER Full-duty-cycle 1 kW linear amplifier including...