ISP2150 2U Rack Server Platform Quick Start Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Before You Begin FCC Declaration of Conformity 4 Cautions and Warnings ...6 Product Regulation Compliance 7 Safety Compliance...7 Electromagnetic Compatibility (EMC 7 ISP2150 Opening and Closing the Front Bezel 8 Locking and Unlocking the Front ...System (Optional Accessory 21 Technical Reference Front Panel Controls and Indicators 25 Back Panel Connectors ...26 Jumpers...27 Server Board Components ...29 Getting Help...30 Order Number: A13687-001
ISP2150 2U Rack Server Platform Quick Start Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Before You Begin FCC Declaration of Conformity 4 Cautions and Warnings ...6 Product Regulation Compliance 7 Safety Compliance...7 Electromagnetic Compatibility (EMC 7 ISP2150 Opening and Closing the Front Bezel 8 Locking and Unlocking the Front ...System (Optional Accessory 21 Technical Reference Front Panel Controls and Indicators 25 Back Panel Connectors ...26 Jumpers...27 Server Board Components ...29 Getting Help...30 Order Number: A13687-001
Quick Start Guide
Page 2
... which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 4 ISP2150 2U Rack Server Platform Quick Start Guide Elam Young Parkway Hillsboro, OR 97124 1-800-628-8686 This equipment has been tested and found at http://...cause harmful interference to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Intel assumes no commitment to update nor to keep current the information contained in a residential installation. The ISP2150 2U Rack Server Platform Product Guide can be determined by turning the equipment off and ...
... which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 4 ISP2150 2U Rack Server Platform Quick Start Guide Elam Young Parkway Hillsboro, OR 97124 1-800-628-8686 This equipment has been tested and found at http://...cause harmful interference to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Intel assumes no commitment to update nor to keep current the information contained in a residential installation. The ISP2150 2U Rack Server Platform Product Guide can be determined by turning the equipment off and ...
Quick Start Guide
Page 3
... B limits for radio noise emissions from Information Technology Equipment. When used near a radio or TV receiver, it may become the cause of radio interference. ISP2150 2U Rack Server Platform Quick Start Guide 5 This equipment has been tested for correct handling. Read the instructions for radio frequency emissions and has been verified to the...
... B limits for radio noise emissions from Information Technology Equipment. When used near a radio or TV receiver, it may become the cause of radio interference. ISP2150 2U Rack Server Platform Quick Start Guide 5 This equipment has been tested for correct handling. Read the instructions for radio frequency emissions and has been verified to the...
Quick Start Guide
Page 4
... adhere to find out how you can damage server components. Disconnect the server from its power source and from any telecommunications links, networks, or modems before doing any of the procedures described in the server may continue to a metal part of the computer chassis. 6 ISP2150 2U Rack Server Platform Quick Start Guide Some circuitry in this...
... adhere to find out how you can damage server components. Disconnect the server from its power source and from any telecommunications links, networks, or modems before doing any of the procedures described in the server may continue to a metal part of the computer chassis. 6 ISP2150 2U Rack Server Platform Quick Start Guide Some circuitry in this...
Quick Start Guide
Page 5
... Emissions CISPR 22, Class B AS/NZ 3548, Class B limits (CISPR 22) VCCI Class B (CISPR 22 B limit) ISP2150 2U Rack Server Platform Quick Start Guide 7 Other uses may require further evaluation. CSA 950-95 UL certified to EN60950 IEC60 950 AS/NZ 3260 (...47 Part 15, Class B ICES-003 Class B EN55022, Class B EN55024 (Immunity) EN61000-3-2 Limit for U.S. Product Regulation Compliance See the ISP2150 2U Rack Server Platform Product Guide for use in computer rack cabinets within computer rooms and similar locations. Safety Compliance USA: Canada: Europe: International: Australian / New...
... Emissions CISPR 22, Class B AS/NZ 3548, Class B limits (CISPR 22) VCCI Class B (CISPR 22 B limit) ISP2150 2U Rack Server Platform Quick Start Guide 7 Other uses may require further evaluation. CSA 950-95 UL certified to EN60950 IEC60 950 AS/NZ 3260 (...47 Part 15, Class B ICES-003 Class B EN55022, Class B EN55024 (Immunity) EN61000-3-2 Limit for U.S. Product Regulation Compliance See the ISP2150 2U Rack Server Platform Product Guide for use in computer rack cabinets within computer rooms and similar locations. Safety Compliance USA: Canada: Europe: International: Australian / New...
Quick Start Guide
Page 6
... you get the system started. Stand in front of the chassis and grasp the edges of the front panel features, refer to your new Intel® ISP2150 system. The hinging mechanism will guide the bezel into the correct position where it upwards. Gently pull the bezel towards you until it to...bezel from the chassis. 3. With the bezel closed you to Front Panel Controls and Indicators. To close the bezel, gently raise it will snap shut. 8 ISP2150 2U Rack Server Platform Quick Start Guide Opening and Closing the Front Bezel With the bezel open position situated below the chassis.
... you get the system started. Stand in front of the chassis and grasp the edges of the front panel features, refer to your new Intel® ISP2150 system. The hinging mechanism will guide the bezel into the correct position where it upwards. Gently pull the bezel towards you until it to...bezel from the chassis. 3. With the bezel closed you to Front Panel Controls and Indicators. To close the bezel, gently raise it will snap shut. 8 ISP2150 2U Rack Server Platform Quick Start Guide Opening and Closing the Front Bezel With the bezel open position situated below the chassis.
Quick Start Guide
Page 7
... into the lock and turn the lock clockwise until it from the system. Pull the cover back and remove it stops (about a quarter turn ). ISP2150 2U Rack Server Platform Quick Start Guide 9 Close the bezel and insert the key into the holes in the handles on it stops (about a quarter turn ). The bezel...
... into the lock and turn the lock clockwise until it from the system. Pull the cover back and remove it stops (about a quarter turn ). ISP2150 2U Rack Server Platform Quick Start Guide 9 Close the bezel and insert the key into the holes in the handles on it stops (about a quarter turn ). The bezel...
Quick Start Guide
Page 8
Attach the small end of your system. 10 ISP2150 2U Rack Server Platform Quick Start Guide Slide the processor into place. With a single-processor configuration, you install only one processor in a system, it must configure its anti-...A 2. cartridge, then attach the large F end (B) to the DIMM sockets). C D B OM09315 3. Remove the new processor from its speed in the empty secondary connector (B) to two Intel® Pentium® II or Pentium III processors (with 100 MHz system bus). After you have installed the processor, you are installing two processors, make...
Attach the small end of your system. 10 ISP2150 2U Rack Server Platform Quick Start Guide Slide the processor into place. With a single-processor configuration, you install only one processor in a system, it must configure its anti-...A 2. cartridge, then attach the large F end (B) to the DIMM sockets). C D B OM09315 3. Remove the new processor from its speed in the empty secondary connector (B) to two Intel® Pentium® II or Pentium III processors (with 100 MHz system bus). After you have installed the processor, you are installing two processors, make...
Quick Start Guide
Page 9
Installing Memory The server only supports 100 MHz PC/100-compliant SDRAM. • Install from 32 MB to 2 GB of unbuffered memory, using up to four single or double-banked DIMMs Or • Install from 32 MB to 2 GB of registered memory, using up to four single or double-banked DIMMs OM09318 ISP2150 2U Rack Server Platform Quick Start Guide 11
Installing Memory The server only supports 100 MHz PC/100-compliant SDRAM. • Install from 32 MB to 2 GB of unbuffered memory, using up to four single or double-banked DIMMs Or • Install from 32 MB to 2 GB of registered memory, using up to four single or double-banked DIMMs OM09318 ISP2150 2U Rack Server Platform Quick Start Guide 11
Quick Start Guide
Page 10
... visit the Intel Support website: http://support.intel.com/support/motherboards/server/l440gx/compat.htm CAUTION Use extreme care when installing a DIMM. For a list of the DIMM into the socket, and press down firmly on the monitor and then the server. 12 ISP2150 2U Rack Server Platform Quick Start... Guide Applying too much pressure can be the same speed and either all registered or all external cables and the power cord to the upright position. 6. To install your server. 2. Connect all unbuffered....
... visit the Intel Support website: http://support.intel.com/support/motherboards/server/l440gx/compat.htm CAUTION Use extreme care when installing a DIMM. For a list of the DIMM into the socket, and press down firmly on the monitor and then the server. 12 ISP2150 2U Rack Server Platform Quick Start... Guide Applying too much pressure can be the same speed and either all registered or all external cables and the power cord to the upright position. 6. To install your server. 2. Connect all unbuffered....
Quick Start Guide
Page 11
... unclipping the retention lever on an antistatic surface. Make sure that it on the right side of the housing. 2. ISP2150 2U Rack Server Platform Quick Start Guide 13 The server has four hot-swappable SCSI hard drive bays. 1. A B OM09323 3. Slide the carrier/drive into the chassis with...Align the drive holes to the drive (A). You must purchase them separately and install them. Installing a Hard Drive AB E D C OM09317 Your server does not include a hard drive. Pull the drive forward and out of the handle. Remove the drive carrier(s) from the drive carrier/drive slide ...
... unclipping the retention lever on an antistatic surface. Make sure that it on the right side of the housing. 2. ISP2150 2U Rack Server Platform Quick Start Guide 13 The server has four hot-swappable SCSI hard drive bays. 1. A B OM09323 3. Slide the carrier/drive into the chassis with...Align the drive holes to the drive (A). You must purchase them separately and install them. Installing a Hard Drive AB E D C OM09317 Your server does not include a hard drive. Pull the drive forward and out of the handle. Remove the drive carrier(s) from the drive carrier/drive slide ...
Quick Start Guide
Page 12
Remove the expansion slot cover for the slot you wish to the chassis. Remove the bracket from the chassis. 2. Remove the thumbscrew (B) holding the cover retention bracket (A) to use. Remove the expansion slot cover (C) for the slot you wish to this server. Installing Add-in Cards B A C You can only add two PCI cards to use. You must use any expansion slots on the riser card. Do not use the PCI slots on the server board. 1. OM09325 14 ISP2150 2U Rack Server Platform Quick Start Guide
Remove the expansion slot cover for the slot you wish to the chassis. Remove the bracket from the chassis. 2. Remove the thumbscrew (B) holding the cover retention bracket (A) to use. Remove the expansion slot cover (C) for the slot you wish to this server. Installing Add-in Cards B A C You can only add two PCI cards to use. You must use any expansion slots on the riser card. Do not use the PCI slots on the server board. 1. OM09325 14 ISP2150 2U Rack Server Platform Quick Start Guide
Quick Start Guide
Page 13
... board-retaining bracket must fit into an open expansion slot on the riser card. Firmly press it into the mating slot in the frame. ISP2150 2U Rack Server Platform Quick Start Guide 15 Set jumpers or switches according to the manufacturer's instructions. 4. Hold board by the slot cover. NOTE If you are installing...
... board-retaining bracket must fit into an open expansion slot on the riser card. Firmly press it into the mating slot in the frame. ISP2150 2U Rack Server Platform Quick Start Guide 15 Set jumpers or switches according to the manufacturer's instructions. 4. Hold board by the slot cover. NOTE If you are installing...
Quick Start Guide
Page 14
...-line CD-ROM drive. Remove the drive from its protective wrapper, and place A it . 1. Reinstall the diskette drive in the top of the chassis. 16 ISP2150 2U Rack Server Platform Quick Start Guide Insert the retention screw (D) on an anti-static surface. 2. Installing a Slim-Line CD-ROM Drive C D Your...
...-line CD-ROM drive. Remove the drive from its protective wrapper, and place A it . 1. Reinstall the diskette drive in the top of the chassis. 16 ISP2150 2U Rack Server Platform Quick Start Guide Insert the retention screw (D) on an anti-static surface. 2. Installing a Slim-Line CD-ROM Drive C D Your...
Quick Start Guide
Page 15
.... 5. C OM09316 Re-Installing a Diskette Drive 1. Connect the signal and power cables to the drive according to the drive. 2. The sides and front of the chassis. 4. ISP2150 2U Rack Server Platform Quick Start Guide 17 Disconnect the power (B) and signal (A) cables from its protective wrapper, and place it forwards as far as possible.
.... 5. C OM09316 Re-Installing a Diskette Drive 1. Connect the signal and power cables to the drive according to the drive. 2. The sides and front of the chassis. 4. ISP2150 2U Rack Server Platform Quick Start Guide 17 Disconnect the power (B) and signal (A) cables from its protective wrapper, and place it forwards as far as possible.
Quick Start Guide
Page 16
... rear panel of the system with the bracket flange flush with left and right front brackets to the sides of the system. B A C OM09334 18 ISP2150 2U Rack Server Platform Quick Start Guide Your system comes with the front panel. 2. Mount the brackets to the system. Before installing the system, be sure to refer...
... rear panel of the system with the bracket flange flush with left and right front brackets to the sides of the system. B A C OM09334 18 ISP2150 2U Rack Server Platform Quick Start Guide Your system comes with the front panel. 2. Mount the brackets to the system. Before installing the system, be sure to refer...
Quick Start Guide
Page 17
... in the cabinet using the support washers as rollers. Left (A) and right and left rear mounting brackets also come with the system. A B OM09336 A OM09346 ISP2150 2U Rack Server Platform Quick Start Guide 19 Slide the system into the rack using the supplied mounting bolts (C) supplied by the cabinet manufacturer. Mount the back support...
... in the cabinet using the support washers as rollers. Left (A) and right and left rear mounting brackets also come with the system. A B OM09336 A OM09346 ISP2150 2U Rack Server Platform Quick Start Guide 19 Slide the system into the rack using the supplied mounting bolts (C) supplied by the cabinet manufacturer. Mount the back support...
Quick Start Guide
Page 18
... to the center channel of the system as shown in a Center-Mount, Relay Rack 1. Your system comes with the front panel. A B OM09335 A OM09347 20 ISP2150 2U Rack Server Platform Quick Start Guide Attach the left and right front brackets (A) and mounting bolts (B) to attach them to the system. Mount the brackets mid-way...
... to the center channel of the system as shown in a Center-Mount, Relay Rack 1. Your system comes with the front panel. A B OM09335 A OM09347 20 ISP2150 2U Rack Server Platform Quick Start Guide Attach the left and right front brackets (A) and mounting bolts (B) to attach them to the system. Mount the brackets mid-way...
Quick Start Guide
Page 19
... the rail system. Be sure that the flat end of the inside rail (A) to your system into a four-post, network server cabinet (e.g. Remove the inside rail piece from both sides of the chassis. This action reveals a brass colored finger tab (D) that...your system allows you will need a Phillips screwdriver and assorted lock washers and nuts. 2. D D A B C A B C OM09132 D OM09133 ISP2150 2U Rack Server Platform Quick Start Guide 21 APC Netshelter). Follow these steps to completely separate the inside piece (C) from the outer (A) and middle (B) rail pieces. 3. ...
... the rail system. Be sure that the flat end of the inside rail (A) to your system into a four-post, network server cabinet (e.g. Remove the inside rail piece from both sides of the chassis. This action reveals a brass colored finger tab (D) that...your system allows you will need a Phillips screwdriver and assorted lock washers and nuts. 2. D D A B C A B C OM09132 D OM09133 ISP2150 2U Rack Server Platform Quick Start Guide 21 APC Netshelter). Follow these steps to completely separate the inside piece (C) from the outer (A) and middle (B) rail pieces. 3. ...
Quick Start Guide
Page 20
... illustration to the right, the left photo (A) shows the left -rear bracket. (The photo shows the rails inside the A brackets yet.) OM09145 C D B OM09142 continued 22 ISP2150 2U Rack Server Platform Quick Start Guide