APT LOGIC 3 Manual
Page 4
... impregnated. DOOR SPEED 7-8" per second depending on door BRAKE Solenoid actuated disc brake BEARINGS Output Shaft: Shielded Ball Bearing. Open/Close/Stop w/ LED WIRING TYPE C2 (Factory Shipped) Momentary contact to OPEN & STOP, constant pressure to CLOSE, plus wiring for sensing device to reverse and auxiliary devices to provide non-contact safety...
... impregnated. DOOR SPEED 7-8" per second depending on door BRAKE Solenoid actuated disc brake BEARINGS Output Shaft: Shielded Ball Bearing. Open/Close/Stop w/ LED WIRING TYPE C2 (Factory Shipped) Momentary contact to OPEN & STOP, constant pressure to CLOSE, plus wiring for sensing device to reverse and auxiliary devices to provide non-contact safety...
APT LOGIC 3 Manual
Page 6
... Make sure that suit your application. Close the door and mark the inside vertical centerline of Travel Nut Bolt Door Travel Projection 4. Open your door to the illustrations and instructions below . Using the door as shown. Refer to the highest point of travel clearance for the...a mounting pad for the top edge of Door Header Bracket Drill Pattern Operator Alignment 6 Raise the operator to a horizontal position above the door opening. Position the operator on the floor below the header bracket. 2. Draw an intersecting horizontal line on the header wall 4" (10.2 cm) ...
... Make sure that suit your application. Close the door and mark the inside vertical centerline of Travel Nut Bolt Door Travel Projection 4. Open your door to the illustrations and instructions below . Using the door as shown. Refer to the highest point of travel clearance for the...a mounting pad for the top edge of Door Header Bracket Drill Pattern Operator Alignment 6 Raise the operator to a horizontal position above the door opening. Position the operator on the floor below the header bracket. 2. Draw an intersecting horizontal line on the header wall 4" (10.2 cm) ...
APT LOGIC 3 Manual
Page 8
... plate to allow nut to the wiring diagram provided on page 14. SAFETY (Aux. Close) Limit Switch CLOSE Limit Switch CLOSE OPEN 8 OPEN Limit Switch Important Notes: a. See field connection terminals identified as door fully seats at the floor. COIL CORD Connect operator end of... limit nuts are positioned between the limit switches before making any sensing edge wiring connections to the wall approximately halfway up the door opening . 4. The sensing edge may be electrically connected by the door manufacturer, mount the sensing edge on safety devices, please contact your...
... plate to allow nut to the wiring diagram provided on page 14. SAFETY (Aux. Close) Limit Switch CLOSE Limit Switch CLOSE OPEN 8 OPEN Limit Switch Important Notes: a. See field connection terminals identified as door fully seats at the floor. COIL CORD Connect operator end of... limit nuts are positioned between the limit switches before making any sensing edge wiring connections to the wall approximately halfway up the door opening . 4. The sensing edge may be electrically connected by the door manufacturer, mount the sensing edge on safety devices, please contact your...
APT LOGIC 3 Manual
Page 9
..., either manually or by using the door control or remote. ADJUSTMENT EMERGENCY DISCONNECT SYSTEM TO DISCONNECT DOOR FROM OPERATOR The door should be in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle to disengage trolley ONLY when door is clear of persons and obstructions.
..., either manually or by using the door control or remote. ADJUSTMENT EMERGENCY DISCONNECT SYSTEM TO DISCONNECT DOOR FROM OPERATOR The door should be in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle to disengage trolley ONLY when door is clear of persons and obstructions.
APT LOGIC 3 Manual
Page 10
... clutch to slip if the door is met and causes the clutch to slip, the Auxiliary Reversal System will return the door to the full open position when closing door runs into or comes across an obstruction. Reinstall cotterpin. It is very little tension on the clutch shaft. 2. The Auxiliary Reversal... NOT a substitute for ALL installations. Replace brake assembly when necessary. If an obstruction is obstructed. Refer to detect if a closing or stops the door when opening. 1.
... clutch to slip if the door is met and causes the clutch to slip, the Auxiliary Reversal System will return the door to the full open position when closing door runs into or comes across an obstruction. Reinstall cotterpin. It is very little tension on the clutch shaft. 2. The Auxiliary Reversal... NOT a substitute for ALL installations. Replace brake assembly when necessary. If an obstruction is obstructed. Refer to detect if a closing or stops the door when opening. 1.
APT LOGIC 3 Manual
Page 12
...WARNING To prevent possible SERIOUS INJURY or DEATH, install CAUTION reversing sensors when the 3-button control station is recommended. Reversing devices are recommended for OPEN/CLOSE/STOP) is out of sight of control station. 3. A R31 U7 D8 C3Ø C18 P1Ø C17 C25 POWER D19 ...VOLT AC 24V AC 13 24 VOLT AC TIMER DEFEAT 12 TIMER DEFEAT CMN 11 COMMON MAS 10 MAINTENANCE ALERT SYSTEM EYES 9 PHOTO EYES (LiftMaster Only) EDGE 8 REVERSE OPEN 7 OPEN CLOSE 6 CLOSE STOP 5 STOP CMN 4 COMMON 3 INTERLOCK 2 INTERLOCK SBC 1 SINGLE BUTTON CONTROL MOUNTING INSTRUCTIONS 1. OR IN THE AREA...
...WARNING To prevent possible SERIOUS INJURY or DEATH, install CAUTION reversing sensors when the 3-button control station is recommended. Reversing devices are recommended for OPEN/CLOSE/STOP) is out of sight of control station. 3. A R31 U7 D8 C3Ø C18 P1Ø C17 C25 POWER D19 ...VOLT AC 24V AC 13 24 VOLT AC TIMER DEFEAT 12 TIMER DEFEAT CMN 11 COMMON MAS 10 MAINTENANCE ALERT SYSTEM EYES 9 PHOTO EYES (LiftMaster Only) EDGE 8 REVERSE OPEN 7 OPEN CLOSE 6 CLOSE STOP 5 STOP CMN 4 COMMON 3 INTERLOCK 2 INTERLOCK SBC 1 SINGLE BUTTON CONTROL MOUNTING INSTRUCTIONS 1. OR IN THE AREA...
APT LOGIC 3 Manual
Page 13
STANDARD POWER & CONTROL CONNECTION DIAGRAMS Radio Control (24V DC only) CPS-L & CPS-LN4 R3 R2 R1 Sensing Edge Timer Defeat Switch Maintenance Alert LED (RD) (WH) Open Close Stop Open/Close Single Button OPEN CLOSE STOP 3-Button Station Remove Jumper To Install External Interlock Single Phase Power Wiring Line Power 115 Vac Single Phase Hot Neutral Gnd 13
STANDARD POWER & CONTROL CONNECTION DIAGRAMS Radio Control (24V DC only) CPS-L & CPS-LN4 R3 R2 R1 Sensing Edge Timer Defeat Switch Maintenance Alert LED (RD) (WH) Open Close Stop Open/Close Single Button OPEN CLOSE STOP 3-Button Station Remove Jumper To Install External Interlock Single Phase Power Wiring Line Power 115 Vac Single Phase Hot Neutral Gnd 13
APT LOGIC 3 Manual
Page 14
... 11 C3Ø CLOSE D21 D2Ø D15 D23 P1Ø C17 C25 POWER D19 TIMER DEFEAT R8 D17 MAS D28 R31 U7 D8 D22 OPEN D1 EDGE EYES 4 C18 ENABLE TIMER J3ØØ 3 2 MRT MID TIMER J1 D25 X1 D27 D26 D24 Ø14LGØ657-A Ø14GPØ...) 115 / 230 VOLT 1PH. POWER IN (WH) COM 120 120 / 240 VAC VAC (WH) NO COM C (YE) +24 VAC -24 VAC COIL (GY) (WH) COM OPEN L/S NO NC (RD) (PU) (WH) COM NO CLOSE L/S NC NOTE: Lock Sensor is provided on Models DJ and DH only, red wire from main harness...
... 11 C3Ø CLOSE D21 D2Ø D15 D23 P1Ø C17 C25 POWER D19 TIMER DEFEAT R8 D17 MAS D28 R31 U7 D8 D22 OPEN D1 EDGE EYES 4 C18 ENABLE TIMER J3ØØ 3 2 MRT MID TIMER J1 D25 X1 D27 D26 D24 Ø14LGØ657-A Ø14GPØ...) 115 / 230 VOLT 1PH. POWER IN (WH) COM 120 120 / 240 VAC VAC (WH) NO COM C (YE) +24 VAC -24 VAC COIL (GY) (WH) COM OPEN L/S NO NC (RD) (PU) (WH) COM NO CLOSE L/S NC NOTE: Lock Sensor is provided on Models DJ and DH only, red wire from main harness...
APT LOGIC 3 Manual
Page 15
... DEFEAT 12 CMN 11 SINGLE PHASE CONTACTOR/3 PH MOTOR DIRECTION SLS D26 D16 CLS D27 4 D23 EYES D15 P7 MRT MID TIMER D1 EDGE D22 OPEN D2Ø TIMER RADIO 1 2 3 ENABLE D36 CLOSE D21 RELAY A C77 C73 L1 L5 P6 RELAY B D35 T E2 D1 STOP D13 TS FSTS DIAG C2 B2... FAILSAFE SBC PROG (B2 C2 D1 E2) S8 NON FAILSAFE D14 P1 D34 MAS 10 EYES 9 EDGE 8 OPEN 7 CLOSE 6 STOP 5 CMN 4 3 2 SBC 1 F1 C54 C71 C78 ® Motor Direction Jumper Single Phase & Three Phase Jumper Maintenance Alert System Button for Programming...
... DEFEAT 12 CMN 11 SINGLE PHASE CONTACTOR/3 PH MOTOR DIRECTION SLS D26 D16 CLS D27 4 D23 EYES D15 P7 MRT MID TIMER D1 EDGE D22 OPEN D2Ø TIMER RADIO 1 2 3 ENABLE D36 CLOSE D21 RELAY A C77 C73 L1 L5 P6 RELAY B D35 T E2 D1 STOP D13 TS FSTS DIAG C2 B2... FAILSAFE SBC PROG (B2 C2 D1 E2) S8 NON FAILSAFE D14 P1 D34 MAS 10 EYES 9 EDGE 8 OPEN 7 CLOSE 6 STOP 5 CMN 4 3 2 SBC 1 F1 C54 C71 C78 ® Motor Direction Jumper Single Phase & Three Phase Jumper Maintenance Alert System Button for Programming...
APT LOGIC 3 Manual
Page 16
... (roll-back feature) plus wiring for limit switch adjustment instructions. LEDs on page 15 for sensing device to open and close , open override. Programmable mid stop available with open override plus wiring for all component locations. SET THE SELECTOR DIAL TO THE DESIRED WIRING MODE: NOTE: For ... to program as well as have door control at the electrical box. NOTE: Refer to logic board illustration on the logic board are Open Limit Switch (OLS), Close Limit Switch (CLS) and Sensing Limit Switch (SLS). Release of the different wiring types to determine which ...
... (roll-back feature) plus wiring for limit switch adjustment instructions. LEDs on page 15 for sensing device to open and close , open override. Programmable mid stop available with open override plus wiring for all component locations. SET THE SELECTOR DIAL TO THE DESIRED WIRING MODE: NOTE: For ... to program as well as have door control at the electrical box. NOTE: Refer to logic board illustration on the logic board are Open Limit Switch (OLS), Close Limit Switch (CLS) and Sensing Limit Switch (SLS). Release of the different wiring types to determine which ...
APT LOGIC 3 Manual
Page 17
...Station and 1 & 3 Button Remote Control. (NOTE: Requires Optional self monitoring photo eyes to operate.) T Momentary contact to open, close, and stop, with open , close and stop. Auxiliary controls can be installed to operate door for each of the following failsafe wiring types. The ...Station, 1 & 3 Button Remote Control. 17 See Self Monitoring Safety Device Options. Every device that the door may be connected to open , close and stop button first. User set Timer To Close. See Self Monitoring Safety Device Options. External interlocks may be installed. ...
...Station and 1 & 3 Button Remote Control. (NOTE: Requires Optional self monitoring photo eyes to operate.) T Momentary contact to open, close, and stop, with open , close and stop. Auxiliary controls can be installed to operate door for each of the following failsafe wiring types. The ...Station, 1 & 3 Button Remote Control. 17 See Self Monitoring Safety Device Options. Every device that the door may be connected to open , close and stop button first. User set Timer To Close. See Self Monitoring Safety Device Options. External interlocks may be installed. ...
APT LOGIC 3 Manual
Page 18
... up mid stops. The programming mode is exited if no activity is out of sight of this function. MODE B2 C2 D1 E2 T, TS FSTS OPEN STOP OPERATION CLOSE Reverse Constant Timer To Pressure Close 1. WARNING To prevent possible SERIOUS INJURY or DEATH, install CAUTION reversing sensors ...(wiring C2, D1 and E2 ). ERASING REMOTES Press and hold the remote button until the LED flashes rapidly, then release remote button. RADIO LiftMaster P4 E1 R29 C11 D3Ø2 K3 Ø14LGØ65 X1 C54 U1 C71 C78 ® OLS D25 REV MID D24 SLS D26...
... up mid stops. The programming mode is exited if no activity is out of sight of this function. MODE B2 C2 D1 E2 T, TS FSTS OPEN STOP OPERATION CLOSE Reverse Constant Timer To Pressure Close 1. WARNING To prevent possible SERIOUS INJURY or DEATH, install CAUTION reversing sensors ...(wiring C2, D1 and E2 ). ERASING REMOTES Press and hold the remote button until the LED flashes rapidly, then release remote button. RADIO LiftMaster P4 E1 R29 C11 D3Ø2 K3 Ø14LGØ65 X1 C54 U1 C71 C78 ® OLS D25 REV MID D24 SLS D26...
APT LOGIC 3 Manual
Page 19
...of the 23 channels on the logic board. To program the STOP button to a remote control press the OPEN button on the radio receiver.) 5. The RADIO LED on the logic board will flash and then stay on... button on the logic board (the RADIO LED will flash and then stay on the radio receiver.) 4. OPEN Open CLOSE Close Stop STOP R31 U7 D8 U1 Ø14LGØ657-A Ø14GPØ657-A P4 C3...RADIO SLS D26 CLS D27 MRT MID TIMER 1 2 3 D36 RELAY A 4 D23 EYES D15 D1 EDGE D22 OPEN D2Ø TIMER ENABLE CLOSE D21 C77 C73 RELAY B D35 T E2 STOP D13 TS FSTS L1 L5 P6 D1...
...of the 23 channels on the logic board. To program the STOP button to a remote control press the OPEN button on the radio receiver.) 5. The RADIO LED on the logic board will flash and then stay on... button on the logic board (the RADIO LED will flash and then stay on the radio receiver.) 4. OPEN Open CLOSE Close Stop STOP R31 U7 D8 U1 Ø14LGØ657-A Ø14GPØ657-A P4 C3...RADIO SLS D26 CLS D27 MRT MID TIMER 1 2 3 D36 RELAY A 4 D23 EYES D15 D1 EDGE D22 OPEN D2Ø TIMER ENABLE CLOSE D21 C77 C73 RELAY B D35 T E2 STOP D13 TS FSTS L1 L5 P6 D1...
APT LOGIC 3 Manual
Page 20
... is counted as one cycle. Press the MAS again to Maintenance Alert System Activation Timer. Adds 3 Months to complete the programming. The OPEN button LED will flash once for every 5,000 cycle increment programmed and the CLOSE button LED will flash once for every 5,000 cycles increments... (12 months). Clears memory, sets Maintenance Alert System Activation Counter to PROGRAM. 4. Press the STOP button once to exit. 20 Press the OPEN button once for every 3 months. 8. Setting this feature will vary depending on the logic board is serviced after the MAS LED has started...
... is counted as one cycle. Press the MAS again to Maintenance Alert System Activation Timer. Adds 3 Months to complete the programming. The OPEN button LED will flash once for every 5,000 cycle increment programmed and the CLOSE button LED will flash once for every 5,000 cycles increments... (12 months). Clears memory, sets Maintenance Alert System Activation Counter to PROGRAM. 4. Press the STOP button once to exit. 20 Press the OPEN button once for every 3 months. 8. Setting this feature will vary depending on the logic board is serviced after the MAS LED has started...
APT LOGIC 3 Manual
Page 21
..., then press the STOP button. 5. Press the CLOSE button for every 60 seconds the operator should wait before closing the door. 6. The OPEN/CLOSE button LEDs will work from the "Mid Stop" position. Example: To close the door after preset time. Press the TIMER button to...Timer to Close will flash to "PROGRAM." 3. TIMER TO CLOSE Feature: Timer automatically closes door after 70 seconds. Benefit: The door will not open position. Requirements: Must have at the "Mid Stop," photo eyes and other safety devices will automatically close automatically after pre set to TS, T ...
..., then press the STOP button. 5. Press the CLOSE button for every 60 seconds the operator should wait before closing the door. 6. The OPEN/CLOSE button LEDs will work from the "Mid Stop" position. Example: To close the door after preset time. Press the TIMER button to...Timer to Close will flash to "PROGRAM." 3. TIMER TO CLOSE Feature: Timer automatically closes door after 70 seconds. Benefit: The door will not open position. Requirements: Must have at the "Mid Stop," photo eyes and other safety devices will automatically close automatically after pre set to TS, T ...
APT LOGIC 3 Manual
Page 22
...TIMER SET LED will be installed. To deactivate the timer for more than one time for 5 seconds until the door reaches the open position press the STOP button. We require the use of time to be reactivated on wiring type AUTOMATICALLY LEARNED PROGRAMMING AUXILIARY REVERSAL ... automatically learned and does not require programming. All timer modes require a supervised safety device to pass. (An internal stop position. 5. LOSE OPEN RPM Sensor Logic Board 22 PROGRAMMING TIMER TO CLOSE PROGRAM TIMER TO CLOSE BY EXAMPLE (Method 2): To Program: 1. Wait for desired amount ...
...TIMER SET LED will be installed. To deactivate the timer for more than one time for 5 seconds until the door reaches the open position press the STOP button. We require the use of time to be reactivated on wiring type AUTOMATICALLY LEARNED PROGRAMMING AUXILIARY REVERSAL ... automatically learned and does not require programming. All timer modes require a supervised safety device to pass. (An internal stop position. 5. LOSE OPEN RPM Sensor Logic Board 22 PROGRAMMING TIMER TO CLOSE PROGRAM TIMER TO CLOSE BY EXAMPLE (Method 2): To Program: 1. Wait for desired amount ...
APT LOGIC 3 Manual
Page 23
... kit RDGRNCARD and must have at right. See Red/Green warning light instructions for the door to "PROGRAM." 3. Once the door has reached the open limit. 5. NOTE: To reset MRT only, turn on the OPTION BOARD will turn selector dial to program and press and hold the MRT button...close . TIMER SETTING RED LAMP HOLDER RECEIVES POWER Timer setting equals Activates when the door closes and until the MAS led flashes rapidly. Press the OPEN button and wait for further details. Benefit: Advanced warning of the following safety devices attached: CPS-L, CPS-LN4 or CPS3. When the door ...
... kit RDGRNCARD and must have at right. See Red/Green warning light instructions for the door to "PROGRAM." 3. Once the door has reached the open limit. 5. NOTE: To reset MRT only, turn on the OPTION BOARD will turn selector dial to program and press and hold the MRT button...close . TIMER SETTING RED LAMP HOLDER RECEIVES POWER Timer setting equals Activates when the door closes and until the MAS led flashes rapidly. Press the OPEN button and wait for further details. Benefit: Advanced warning of the following safety devices attached: CPS-L, CPS-LN4 or CPS3. When the door ...
APT LOGIC 3 Manual
Page 25
... DIAGNOSTIC CHART The logic board has several LEDs to assist in verifying the operator is functioning properly. Solid off this LED. Indicates open or close command has been given to close command has been given to the motor. LED turns on indicates photo eyes learned. Indicates...System has been activated or an error code has been triggered. Indicates a closed circuit between common and terminal 8. LED Power Stop Open COLOR Green Green Yellow Close Yellow Eyes Green Timer Defeat OLS CLS SLS Edge Mid Stop Timer Enabled Yellow Yellow Yellow Yellow Yellow ...
... DIAGNOSTIC CHART The logic board has several LEDs to assist in verifying the operator is functioning properly. Solid off this LED. Indicates open or close command has been given to close command has been given to the motor. LED turns on indicates photo eyes learned. Indicates...System has been activated or an error code has been triggered. Indicates a closed circuit between common and terminal 8. LED Power Stop Open COLOR Green Green Yellow Close Yellow Eyes Green Timer Defeat OLS CLS SLS Edge Mid Stop Timer Enabled Yellow Yellow Yellow Yellow Yellow ...
APT LOGIC 3 Manual
Page 26
... ➤ Check the RPM assembly for loose connections. correctly b) Interlock switch ➤ Check interlock switch(es) for 5 seconds. AN EXTRA OPEN OR CLOSE COMMAND IS ABLE TO GET DOOR TO COMPLETE CYCLE The Maximum Run Timer is replaced. ➤ Replace logic board. If more than...or control transformer. ➤ Replace logic board. ➤ Check interlock(s). Clear the Mid Stop by using the onboard station. THE DOOR WILL OPEN BUT a) The photo eyes, edge or other sensing WILL ONLY CLOSE AFTER device is obstructed or activated A FIVE SECOND DELAY WITH CONSTANT b) The...
... ➤ Check the RPM assembly for loose connections. correctly b) Interlock switch ➤ Check interlock switch(es) for 5 seconds. AN EXTRA OPEN OR CLOSE COMMAND IS ABLE TO GET DOOR TO COMPLETE CYCLE The Maximum Run Timer is replaced. ➤ Replace logic board. If more than...or control transformer. ➤ Replace logic board. ➤ Check interlock(s). Clear the Mid Stop by using the onboard station. THE DOOR WILL OPEN BUT a) The photo eyes, edge or other sensing WILL ONLY CLOSE AFTER device is obstructed or activated A FIVE SECOND DELAY WITH CONSTANT b) The...
APT LOGIC 3 Manual
Page 27
... default to a constant pressure mode. will flash. Clutch is cleared, the next highest will not respond E6 Rotary dial in the OPEN position 4 blinks E5 Stuck key button pressed for the error to close command. Check transformer secondary for greater The door will run ...invalid position for low voltage. ERROR CODE DESCRIPTION EFFECT E1 MAS triggered (cycles or months) None normal operation E2 No RPM input during opening or closing Operator will continue to Flash on 3-button station 5 blinks 2 minutes. Cleared when safety device is not needed. 27 First...
... default to a constant pressure mode. will flash. Clutch is cleared, the next highest will not respond E6 Rotary dial in the OPEN position 4 blinks E5 Stuck key button pressed for the error to close command. Check transformer secondary for greater The door will run ...invalid position for low voltage. ERROR CODE DESCRIPTION EFFECT E1 MAS triggered (cycles or months) None normal operation E2 No RPM input during opening or closing Operator will continue to Flash on 3-button station 5 blinks 2 minutes. Cleared when safety device is not needed. 27 First...