MIRACLE ONE Manual
Page 2
...Operator Mounting Instructions Removing the Control/Surge Suppressor Boards Mounting the Control Box Wiring 1 Operator to the Surge Suppressor Board Wiring 2 Operators... (Master/Second) to change without the expressed written permission of Maglock / Solenoid Relay Close Delay Option (Master / Second Only) Emergency Key Release Troubleshooting Optional Solar Power Miracle 1 Accessories Miracle 1 Parts Illustration Miracle...and Proximity Switch "Gate Opening Inside" Installation of Maglock / Solenoid Relay "Gate Opening Outside" ...
...Operator Mounting Instructions Removing the Control/Surge Suppressor Boards Mounting the Control Box Wiring 1 Operator to the Surge Suppressor Board Wiring 2 Operators... (Master/Second) to change without the expressed written permission of Maglock / Solenoid Relay Close Delay Option (Master / Second Only) Emergency Key Release Troubleshooting Optional Solar Power Miracle 1 Accessories Miracle 1 Parts Illustration Miracle...and Proximity Switch "Gate Opening Inside" Installation of Maglock / Solenoid Relay "Gate Opening Outside" ...
MIRACLE ONE Manual
Page 9
... the gate operator. Be sure to read and follow all these important instructions before installation of injury to persons, The Miracle-1 is completely closed. If the "Timer" is not responsible for Vehicular Gate use ONLY! IMPORTANT SAFETY INSTRUCTIONS WARNING - KEEP GATES PROPERLY MAINTAINED. Elite Access ...doorways. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. DO NOT install on uphill or downhill gates. WARNINGS AND PRECAUTIONS Warning - is to gate hardware. 5. Doing this will bend. DO NOT install upside down. Never let children operate or play with...
... the gate operator. Be sure to read and follow all these important instructions before installation of injury to persons, The Miracle-1 is completely closed. If the "Timer" is not responsible for Vehicular Gate use ONLY! IMPORTANT SAFETY INSTRUCTIONS WARNING - KEEP GATES PROPERLY MAINTAINED. Elite Access ...doorways. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. DO NOT install on uphill or downhill gates. WARNINGS AND PRECAUTIONS Warning - is to gate hardware. 5. Doing this will bend. DO NOT install upside down. Never let children operate or play with...
MIRACLE ONE Manual
Page 20
...it with all necessary local building codes. 19 Although nothing can absorb the tremendous power of wire. Chamberlain Professional Products is ON, gate will hit vehicle obstructing gate path. Use the proper type earth ground rod for your area. 8 Ft The ground wire must be located within 3 feet... devices are not used when timer is not responsible for the ground wire. The earth ground rod must be directed towards the Elite gate operator. Without this path, the intense energy generated by lightning could be a single, whole piece of a direct lightning strike, proper grounding can...
...it with all necessary local building codes. 19 Although nothing can absorb the tremendous power of wire. Chamberlain Professional Products is ON, gate will hit vehicle obstructing gate path. Use the proper type earth ground rod for your area. 8 Ft The ground wire must be located within 3 feet... devices are not used when timer is not responsible for the ground wire. The earth ground rod must be directed towards the Elite gate operator. Without this path, the intense energy generated by lightning could be a single, whole piece of a direct lightning strike, proper grounding can...
MIRACLE ONE Manual
Page 23
...detection. SINGLE OPERATOR LOOP SIZE AND PLACEMENT It is VERY important to have enough space between loops and gates to scale Exit Loop Inside H Safety Loop F I which ever is for a typical single Miracle 1 loop ... 18 ft, then D must be a minimum of 4 feet away from open gate Center Loop B Outside D C Safety Loop A End of open gate! Exit Loop H = G or I G E Distance from open gate Outside Safety Loop: If A = Then C = 6 Feet 4 Feet 9...Caution: Distance "E" must have enough separation between loop and gate when opened or closed. For toll free technical support: 1-888...
...detection. SINGLE OPERATOR LOOP SIZE AND PLACEMENT It is VERY important to have enough space between loops and gates to scale Exit Loop Inside H Safety Loop F I which ever is for a typical single Miracle 1 loop ... 18 ft, then D must be a minimum of 4 feet away from open gate Center Loop B Outside D C Safety Loop A End of open gate! Exit Loop H = G or I G E Distance from open gate Outside Safety Loop: If A = Then C = 6 Feet 4 Feet 9...Caution: Distance "E" must have enough separation between loop and gate when opened or closed. For toll free technical support: 1-888...
MIRACLE ONE Manual
Page 26
... Com N.O. Gnd +24V 23 25 For fail safe operation, connect safety loops in series. Center Loop Allows gate to stay open when vehicles are obstructing gate path. LOOP DETECTOR WIRING Safety Loop Allows gate to stay open when vehicles are obstructing gate path. Gnd +24V 23 25 Elite Part # A 24 17 18 Com N.O. Gnd +24V 21...
... Com N.O. Gnd +24V 23 25 For fail safe operation, connect safety loops in series. Center Loop Allows gate to stay open when vehicles are obstructing gate path. LOOP DETECTOR WIRING Safety Loop Allows gate to stay open when vehicles are obstructing gate path. Gnd +24V 23 25 Elite Part # A 24 17 18 Com N.O. Gnd +24V 21...
MIRACLE ONE Manual
Page 27
... Open Position Potential Entrapment Area (Shaded) Less than 18" Reflector and Bracket If multiple sensors are being used in class I or class II gate operator, like the following: OMRON Retro-Reflective Photocell, Model: E3K-R10K4-NR BURGLAR ALARM INPUT UL SENSOR CENTER LOOP SAFETY LOOP STRIKE INPUT GROUND RADIO +24 ... INPUT 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Elite Part # A OMRON Important! This switch must be used , all of injury, You must install a photocell sensor when the gate opens to less than 18" from a wall or any other object or potential entrapment installation. ...
... Open Position Potential Entrapment Area (Shaded) Less than 18" Reflector and Bracket If multiple sensors are being used in class I or class II gate operator, like the following: OMRON Retro-Reflective Photocell, Model: E3K-R10K4-NR BURGLAR ALARM INPUT UL SENSOR CENTER LOOP SAFETY LOOP STRIKE INPUT GROUND RADIO +24 ... INPUT 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Elite Part # A OMRON Important! This switch must be used , all of injury, You must install a photocell sensor when the gate opens to less than 18" from a wall or any other object or potential entrapment installation. ...
MIRACLE ONE Manual
Page 38
... carriage washer placement (Page 12). Check motor wire connections. Single Change Fuse 8 Amps 2 Amps 1.5 Amps 37 TROUBLESHOOTING Check the Fuses If the gate is operating smoothly. Master / Slave Change Fuse 15 Amps 3 Amps 1.5 Amps Caution: If left side of the board and replace if necessary. Replace the fuses...only with specified rating (Supplied by Chamberlain Elite). If the motor will not work, and all LED's on the board are on, change the corresponding fuse on the right side of the LED displays on a regular basis, make sure operator is not moving in any direction be sure...
... carriage washer placement (Page 12). Check motor wire connections. Single Change Fuse 8 Amps 2 Amps 1.5 Amps 37 TROUBLESHOOTING Check the Fuses If the gate is operating smoothly. Master / Slave Change Fuse 15 Amps 3 Amps 1.5 Amps Caution: If left side of the board and replace if necessary. Replace the fuses...only with specified rating (Supplied by Chamberlain Elite). If the motor will not work, and all LED's on the board are on, change the corresponding fuse on the right side of the LED displays on a regular basis, make sure operator is not moving in any direction be sure...
MIRACLE ONE Manual
Page 40
For Toll Free Technical Support: 1-888-ELITE-10 SYSOTNEM RSEEVNESROSRE SAELNASROMR Vertical Gate Level line Horizontal Gate Level line Incorrect Installation 1 The gate is too heavy or the operator or gate is installed incorrectly. 2 A foreign object is on the gate frame while the gate is moving. 3 Gate hinges are too tight or broken and the gate is not moving freely. 4 The gate hits the driveway, curb or other, and gets stuck in an awkward position. 39 TROUBLESHOOTING You will SEE the alarm LED "ON" when...
For Toll Free Technical Support: 1-888-ELITE-10 SYSOTNEM RSEEVNESROSRE SAELNASROMR Vertical Gate Level line Horizontal Gate Level line Incorrect Installation 1 The gate is too heavy or the operator or gate is installed incorrectly. 2 A foreign object is on the gate frame while the gate is moving. 3 Gate hinges are too tight or broken and the gate is not moving freely. 4 The gate hits the driveway, curb or other, and gets stuck in an awkward position. 39 TROUBLESHOOTING You will SEE the alarm LED "ON" when...
MIRACLE ONE Manual
Page 44
...Amp Fuse Miracle 1 Q257 - Replacement Key (Operator made Post 3/14/99) Q258 - 2 Amp Fuse Miracle 1 Q259 - 3 Amp Fuse Miracle M/S Q260 - 15 Amp Fuse Miracle M/S Q262 - Arm Cover Gaskets (Set) Q310 - Miracle 1 Surge Protection Q311- For Toll Free Technical Support: 1-888-ELITE-10 (1-...Board (Single Operator) Q223 - Power Harness (Single Operator) Q227P - Steel Bracket Mounting Plates (2) Q231 - Bracket/Rod Q239 - Limit Switch Harness (Wires and 4 Limit Switches) Q240 MAU - Harness-Motor (Operator Cord) Q300 - UL Audio Alarm MAINTENANCE This swing gate operator is designed...
...Amp Fuse Miracle 1 Q257 - Replacement Key (Operator made Post 3/14/99) Q258 - 2 Amp Fuse Miracle 1 Q259 - 3 Amp Fuse Miracle M/S Q260 - 15 Amp Fuse Miracle M/S Q262 - Arm Cover Gaskets (Set) Q310 - Miracle 1 Surge Protection Q311- For Toll Free Technical Support: 1-888-ELITE-10 (1-...Board (Single Operator) Q223 - Power Harness (Single Operator) Q227P - Steel Bracket Mounting Plates (2) Q231 - Bracket/Rod Q239 - Limit Switch Harness (Wires and 4 Limit Switches) Q240 MAU - Harness-Motor (Operator Cord) Q300 - UL Audio Alarm MAINTENANCE This swing gate operator is designed...