Parts / Components...2 Main Cooler ...2 Castors...2 Interior...2 Thermostat ...3 Rear ...3 CO2 Cylinder ...4 Regulator (Single or Double Gauge 5 Red Air Hose...7 Coupler (Tapper, Tap) ...8 5' Clear Beer Hose...11 Beer Tower...12 Chrome Beer Faucet ...14 Common Issues and Questions 15 My keg of (insert favorite beer) doesn't fit 15 Leaking / Losing CO2...16 Unit Not Cooling Enough ...17 Too much foam ...19 Unit not Dispensing Beer...20 Can I Use Keg Cooler for Import Kegs 21 Beers with Kegs using American Sankey Coupler 22 1
Parts / Components...2 Main Cooler ...2 Castors...2 Interior...2 Thermostat ...3 Rear ...3 CO2 Cylinder ...4 Regulator (Single or Double Gauge 5 Red Air Hose...7 Coupler (Tapper, Tap) ...8 5' Clear Beer Hose...11 Beer Tower...12 Chrome Beer Faucet ...14 Common Issues and Questions 15 My keg of (insert favorite beer) doesn't fit 15 Leaking / Losing CO2...16 Unit Not Cooling Enough ...17 Too much foam ...19 Unit not Dispensing Beer...20 Can I Use Keg Cooler for Import Kegs 21 Beers with Kegs using American Sankey Coupler 22 1
User Manual
Page 4
... for Red Air Hose to pass through Close up of the unit. The back of the refrigerator Compressor is in the back CO2 Cylinder and Regulator are in the back Serial # and spec sheet located on back Has hole for controlling the internal temperature of the thermostat removed from it's housing..., the back is out of the Keg Cooler. The higher the number, the colder the temperature Can be accessed only to check pressure on the regulator, turn unit off Also called the 'cold control' Close up of unit. 3 Thermostat The thermostat, located in the front, top left corner inside the refrigerator...
... for Red Air Hose to pass through Close up of the unit. The back of the refrigerator Compressor is in the back CO2 Cylinder and Regulator are in the back Serial # and spec sheet located on back Has hole for controlling the internal temperature of the thermostat removed from it's housing..., the back is out of the Keg Cooler. The higher the number, the colder the temperature Can be accessed only to check pressure on the regulator, turn unit off Also called the 'cold control' Close up of unit. 3 Thermostat The thermostat, located in the front, top left corner inside the refrigerator...
User Manual
Page 5
These knobs are what the CO2 cylinder bracket attach to the rear of the unit Valve must be opened ALL the way for proper operation of the unit with the cylinder bracket, CO2 cylinder, regulator, and air hose. CO2 Cylinder Metal air canister designed to hold compressed air Has brass valve that regulator connects to Black On/Off handle to start/stop flow of air Does NOT come full, must be filled prior to use Sits in cylinder bracket, which attaches to . View of the rear of the unit CO2 cylinder (left) and cylinder bracket (right) 4
These knobs are what the CO2 cylinder bracket attach to the rear of the unit Valve must be opened ALL the way for proper operation of the unit with the cylinder bracket, CO2 cylinder, regulator, and air hose. CO2 Cylinder Metal air canister designed to hold compressed air Has brass valve that regulator connects to Black On/Off handle to start/stop flow of air Does NOT come full, must be filled prior to use Sits in cylinder bracket, which attaches to . View of the rear of the unit CO2 cylinder (left) and cylinder bracket (right) 4
User Manual
Page 6
... There is a rubber washer built in p.s.i. (lbs. There are 2 types of a brass fitting that attaches it via hex nut to the cylinder. Single Gauge Regulator Right - This nut must be firmly seated, and tightened with a wrench. Gauges indicate air pressure in to the connection to prevent leaks. The... regulator also has a secondary shut off valve, which can shut off valve must be all the way open for proper operation Flathead screw sticking out ...
... There is a rubber washer built in p.s.i. (lbs. There are 2 types of a brass fitting that attaches it via hex nut to the cylinder. Single Gauge Regulator Right - This nut must be firmly seated, and tightened with a wrench. Gauges indicate air pressure in to the connection to prevent leaks. The... regulator also has a secondary shut off valve, which can shut off valve must be all the way open for proper operation Flathead screw sticking out ...
User Manual
Page 7
... "ON" or "Open" setting. Typically between 10-14 p.s.i. Screw used to adjust the pressure to CO2 cylinder. Attaches to the Keg. Air pressure in to regulator. Air comes in the CO2 cylinder (double gauge only) Attaches to Red Air Hose. Above: Another type of secondary cut off valve in the "Off...
... "ON" or "Open" setting. Typically between 10-14 p.s.i. Screw used to adjust the pressure to CO2 cylinder. Attaches to the Keg. Air pressure in to regulator. Air comes in the CO2 cylinder (double gauge only) Attaches to Red Air Hose. Above: Another type of secondary cut off valve in the "Off...
User Manual
Page 8
... hose coming in through hole and attached to coupler via the hex nut. Red air hose running from regulator through hole in back of cooler to the interior Attaches to coupler with hex nut Below: Barbed connector ...where Red Hose connects to interior of regulator with hose clamp Runs from regulator through hole to Coupler. Red Air Hose The red air hose is the red tube... the runs between the bottom of the regulator (under the secondary cut off valve) and the coupler 5/16" Inner Diameter and 9/16" Outer ...
... hose coming in through hole and attached to coupler via the hex nut. Red air hose running from regulator through hole in back of cooler to the interior Attaches to coupler with hex nut Below: Barbed connector ...where Red Hose connects to interior of regulator with hose clamp Runs from regulator through hole to Coupler. Red Air Hose The red air hose is the red tube... the runs between the bottom of the regulator (under the secondary cut off valve) and the coupler 5/16" Inner Diameter and 9/16" Outer ...
User Manual
Page 9
... acts as a washer 8 also called pressure release valve. Ball prevents backflow when keg is the part of place can be obtained 3rd party, from the regulator, and beer to flow up to tap keg #14 & #15 - Ball and Retainer. Air Enters coupler. # 5 - Probe that actually breaks seal on keg Handle pulls...
... acts as a washer 8 also called pressure release valve. Ball prevents backflow when keg is the part of place can be obtained 3rd party, from the regulator, and beer to flow up to tap keg #14 & #15 - Ball and Retainer. Air Enters coupler. # 5 - Probe that actually breaks seal on keg Handle pulls...
User Manual
Page 17
If air is leaking from the connection between the CO2 cylinder and the regulator, make sure that there is out of place, and can be reseated just by either feeling around connection points and pressure release should be obvious, ... this is tight. If the Coupler (Tapper) is leaking, and it isn't apparent, spraying soapy water around for info). 16 If it needs to the regulator or coupler, make sure that the washer is in place and that the Couplers Probe won't reach all the washers already in place. Leaking / Losing...
If air is leaking from the connection between the CO2 cylinder and the regulator, make sure that there is out of place, and can be reseated just by either feeling around connection points and pressure release should be obvious, ... this is tight. If the Coupler (Tapper) is leaking, and it isn't apparent, spraying soapy water around for info). 16 If it needs to the regulator or coupler, make sure that the washer is in place and that the Couplers Probe won't reach all the washers already in place. Leaking / Losing...
User Manual
Page 20
... start to high or low, there will most likely caused by inserting foam insulation into the tower. Make sure the CO2 cylinder valve and the regulator valve are no CO2 leaks, and that the proper pressure is too warm or the pressure to straighten glass until full. 19 Make sure there... as beer in the hose going up the tower will be warmer than the beer in the unit. If the beer is set on the regulator. Check the liquid temperature in the keg.
... start to high or low, there will most likely caused by inserting foam insulation into the tower. Make sure the CO2 cylinder valve and the regulator valve are no CO2 leaks, and that the proper pressure is too warm or the pressure to straighten glass until full. 19 Make sure there... as beer in the hose going up the tower will be warmer than the beer in the unit. If the beer is set on the regulator. Check the liquid temperature in the keg.
User Manual
Page 21
Tank valve must be taken to adjust the pressure. If the valve is air pressure? Is the Gauge on the regulator indicating that will bleed off ) fully opened? Find out if the clear beer hose is not pouring beer, there was a problem with assembly and set ...up , then keg is down and in the beer), but that there is only partly open , and screw adjustments don't change pressure, regulator may be some pressure initially (from carbonation in the locked position. Most of the time, if the unit is touching the back wall of the...
Tank valve must be taken to adjust the pressure. If the valve is air pressure? Is the Gauge on the regulator indicating that will bleed off ) fully opened? Find out if the clear beer hose is not pouring beer, there was a problem with assembly and set ...up , then keg is down and in the beer), but that there is only partly open , and screw adjustments don't change pressure, regulator may be some pressure initially (from carbonation in the locked position. Most of the time, if the unit is touching the back wall of the...
User Manual
Page 22
... pulling out the pressure release valve. Also check that deal in beer brewing or restaurant supply. 21 Is the Regulator valve (secondary cut off the air at the CO2 cylinder and the regulator, and unscrew the red air hose from the coupler to inspect the 'check valve assembly'. Make sure all the... right direction, with the tapered end facing into the the coupler, and make sure it should physically fit within the unit. Other styles of the regulator.
... pulling out the pressure release valve. Also check that deal in beer brewing or restaurant supply. 21 Is the Regulator valve (secondary cut off the air at the CO2 cylinder and the regulator, and unscrew the red air hose from the coupler to inspect the 'check valve assembly'. Make sure all the... right direction, with the tapered end facing into the the coupler, and make sure it should physically fit within the unit. Other styles of the regulator.