Installation Instructions
Page 3
...end spade terminals with ranges. See "Electrical Connection" section. 3 Anti-tip bracket B. Thickness of 194° (90°C). The model/serial rating plate is not applicable, use the Standard for use with upturned ends. ■ A UL listed strain relief. Tools needed If using a ...screws to anchor bracket to your cabinets, check with any tools listed here. When such standard is located on the model/serial rating plate. IMPORTANT: To avoid damage to subfloor. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation....
...end spade terminals with ranges. See "Electrical Connection" section. 3 Anti-tip bracket B. Thickness of 194° (90°C). The model/serial rating plate is not applicable, use the Standard for use with upturned ends. ■ A UL listed strain relief. Tools needed If using a ...screws to anchor bracket to your cabinets, check with any tools listed here. When such standard is located on the model/serial rating plate. IMPORTANT: To avoid damage to subfloor. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation....
Installation Instructions
Page 4
... installer determine that the electrical connection and wire size are for dimensional clearances above code standards can be obtained from floor F 2.2 cm) min. Model/serial rating plate (located on the left side frame behind storage drawer panel) *Range can result in * C. 36" (91.4 cm) cooktop height (max.) with the National Electrical...
... installer determine that the electrical connection and wire size are for dimensional clearances above code standards can be obtained from floor F 2.2 cm) min. Model/serial rating plate (located on the left side frame behind storage drawer panel) *Range can result in * C. 36" (91.4 cm) cooktop height (max.) with the National Electrical...
Installation Instructions
Page 5
... through the neutral conductor is less than the total connected load listed on the oven frame behind the control panel or on the model/serial rating plate. **If connecting to a 50-amp circuit, use kits that the range can be provided at the junction box). ■ Wire sizes ...through the neutral conductor. mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral, use a 4-wire power supply cord rated at least 4 ft (1.22 m) long. 4-wire receptacle (14-50R) The minimum conductor sized for use of NEMA Type 14-50R is located behind ...
... through the neutral conductor is less than the total connected load listed on the oven frame behind the control panel or on the model/serial rating plate. **If connecting to a 50-amp circuit, use kits that the range can be provided at the junction box). ■ Wire sizes ...through the neutral conductor. mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral, use a 4-wire power supply cord rated at least 4 ft (1.22 m) long. 4-wire receptacle (14-50R) The minimum conductor sized for use of NEMA Type 14-50R is located behind ...
Installation Instructions
Page 9
...and line 1 (black) wires to the center terminal block post with ranges. 8. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ... terminal block posts with ranges. 5. A F A E B C E A. 10-32 hex nut B. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with one of range. Replace terminal block access cover. 9 Use a Phillips...
...and line 1 (black) wires to the center terminal block post with ranges. 8. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ... terminal block posts with ranges. 5. A F A E B C E A. 10-32 hex nut B. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with one of range. Replace terminal block access cover. 9 Use a Phillips...
Dimension Guide
Page 1
... opening width C. A circuit breaker is protected by adjusting the leveling legs. Specifications subject to improve Dimensions are for use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for : 25" (63.5 cm) countertop depth, 24" (61 cm) base cabinet depth, 36...shown are for planning purposes only. when bottom of wood or metal cabinet is recommended. or 50-amp power supply cord (pigtail). Model/serial rating plate (located on the oven frame behind storage drawer panel) *Range can be raised approximately 1" (2.5 cm) by not less than 1/1/4" ...
... opening width C. A circuit breaker is protected by adjusting the leveling legs. Specifications subject to improve Dimensions are for use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for : 25" (63.5 cm) countertop depth, 24" (61 cm) base cabinet depth, 36...shown are for planning purposes only. when bottom of wood or metal cabinet is recommended. or 50-amp power supply cord (pigtail). Model/serial rating plate (located on the oven frame behind storage drawer panel) *Range can be raised approximately 1" (2.5 cm) by not less than 1/1/4" ...