Installation Guide
Page 3
... gas supply and electrical supply. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. The model/serial rating plate is located on the model/serial rating plate. In Canada, the installation of this range is not applicable, use in the wall or floor where range is a registered...
... gas supply and electrical supply. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. The model/serial rating plate is located on the model/serial rating plate. In Canada, the installation of this range is not applicable, use in the wall or floor where range is a registered...
Installation Guide
Page 4
....9 cm) width E. 25" (63.5 cm) F. E. 30¹⁄₈" (76.5 cm) min. opening width F. For minimum clearance to countertop B. 13" (33 cm) max. M. Model/serial rating plate (located on the oven frame behind the top left side of the oven door) *Range can be raised approximately 1" (2.5 cm) by not less than...
....9 cm) width E. 25" (63.5 cm) F. E. 30¹⁄₈" (76.5 cm) min. opening width F. For minimum clearance to countertop B. 13" (33 cm) max. M. Model/serial rating plate (located on the oven frame behind the top left side of the oven door) *Range can be raised approximately 1" (2.5 cm) by not less than...
Installation Guide
Page 5
... only this range will not be used in insufficient gas supply. If the metal chassis of the range is located on the model/serial rating plate for use with an electronic ignition system that will operate. Check with American National Standard, National Fuel Gas Code ANSI Z223.1 - latest... edition. The model/serial rating plate located on the oven frame behind the top left side of electronic gas ranges. ■ The wiring diagram is not grounded, no keypads...
... only this range will not be used in insufficient gas supply. If the metal chassis of the range is located on the model/serial rating plate for use with an electronic ignition system that will operate. Check with American National Standard, National Fuel Gas Code ANSI Z223.1 - latest... edition. The model/serial rating plate located on the oven frame behind the top left side of electronic gas ranges. ■ The wiring diagram is not grounded, no keypads...
Installation Guide
Page 6
... ■ Must include a shutoff valve: The supply line must be at least 1" water column pressure above the manifold pressure shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m). Shipping base 4. Rear leveling leg C. All strains must be disconnected from the gas supply ...gas supplier if you are reduced at test pressures equal to or less than ½ psi (3.5 kPa). Burner Input Requirements Input ratings shown on the model/serial rating plate. Failure to do so can result in -line connection to the range. Remove oven racks and parts package from the ...
... ■ Must include a shutoff valve: The supply line must be at least 1" water column pressure above the manifold pressure shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m). Shipping base 4. Rear leveling leg C. All strains must be disconnected from the gas supply ...gas supplier if you are reduced at test pressures equal to or less than ½ psi (3.5 kPa). Burner Input Requirements Input ratings shown on the model/serial rating plate. Failure to do so can result in -line connection to the range. Remove oven racks and parts package from the ...
Installation Guide
Page 14
.... Replace the Natural gas orifice spud with 1 color dot, and have a groove in the hex area. LP Gas Orifice Spud Chart for Surface Burners Burner Rating Color Size ID Number 14,000 BTU 11,000 BTU 8,000 BTU 5,000 BTU Yellow/Orange Yellow/Brown Yellow/Black Yellow/White 1.07 mm 0.99...
.... Replace the Natural gas orifice spud with 1 color dot, and have a groove in the hex area. LP Gas Orifice Spud Chart for Surface Burners Burner Rating Color Size ID Number 14,000 BTU 11,000 BTU 8,000 BTU 5,000 BTU Yellow/Orange Yellow/Brown Yellow/Black Yellow/White 1.07 mm 0.99...
Installation Guide
Page 17
Set gas orifice spud aside. A B XXX A. Oven bottom 4. Stamped number Refer to the following chart for the remaining burners. Natural Gas Orifice Spud Chart Burner Rating Color Size ID Number 17,000 BTU 15,000/15,500 BTU 14,200 BTU 13,000/13,500 BTU 12,000/12,500 BTU 9,...
Set gas orifice spud aside. A B XXX A. Oven bottom 4. Stamped number Refer to the following chart for the remaining burners. Natural Gas Orifice Spud Chart Burner Rating Color Size ID Number 17,000 BTU 15,000/15,500 BTU 14,200 BTU 13,000/13,500 BTU 12,000/12,500 BTU 9,...
Dimension Guide
Page 1
... type of gas that resist the action of wood or metal cabinet is covered by ½" (13.0 mm) minimum. Model/serial rating plate (located on the oven frame behind the storage drawer on the right-hand side oven door frame has information on longer runs may... hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for planning purposes only. The model/serial rating plate located behind the top left side of E.I . 17" (43.2 cm) J. 4¹⁄₂" (11.4 cm) K. 2" (5.1 cm) L. 2" (5.1 cm) min. 30" (76.2...
... type of gas that resist the action of wood or metal cabinet is covered by ½" (13.0 mm) minimum. Model/serial rating plate (located on the oven frame behind the storage drawer on the right-hand side oven door frame has information on longer runs may... hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for planning purposes only. The model/serial rating plate located behind the top left side of E.I . 17" (43.2 cm) J. 4¹⁄₂" (11.4 cm) K. 2" (5.1 cm) L. 2" (5.1 cm) min. 30" (76.2...