RS232 codes- Projectors
Page 8
... of not accepting the command to data portion to return it . ( See each command description.) Response : This sets data added to a response to send it . (Example) Power On Command: 02H 00H FFH F0H 00H CKS NAK: A2H 00H 01H 20H 02H DATA01 DATA02 CKS Data Contents DATA01 Error types 00H : Not...
... of not accepting the command to data portion to return it . ( See each command description.) Response : This sets data added to a response to send it . (Example) Power On Command: 02H 00H FFH F0H 00H CKS NAK: A2H 00H 01H 20H 02H DATA01 DATA02 CKS Data Contents DATA01 Error types 00H : Not...
RS232 codes- Projectors
Page 10
... LAN card ] The LAN connections will differ depending on supported LAN cards, visit: Global: http://www.nec-pj.com/ [Port Number] The TCP port number used is used. - List of Commands * Example for command Command name Example 006. INPUT SW CHANGE 020. SOUND MUTE ON 023. ONSCREEN MUTE ON 025. IMAGE MODE ADJUST...
... LAN card ] The LAN connections will differ depending on supported LAN cards, visit: Global: http://www.nec-pj.com/ [Port Number] The TCP port number used is used. - List of Commands * Example for command Command name Example 006. INPUT SW CHANGE 020. SOUND MUTE ON 023. ONSCREEN MUTE ON 025. IMAGE MODE ADJUST...
RS232 codes- Projectors
Page 14
... 70H D0H D0H D0H D0H 80H 80H 90H (*3) Checksum: "CKS" inscription This is the value of the error number at the time of an error. Example: 20H 81H 01H 60H 01H 00H 03H CKS (*4) Response error number This is the value of the lower 8 bits of the results calculated in byte...
... 70H D0H D0H D0H D0H 80H 80H 90H (*3) Checksum: "CKS" inscription This is the value of the error number at the time of an error. Example: 20H 81H 01H 60H 01H 00H 03H CKS (*4) Response error number This is the value of the lower 8 bits of the results calculated in byte...
RS232 codes- Projectors
Page 23
... the time of a success 22H 10H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 03H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * When switch to the Video connector 02H 03H 00H 00H 02H 01H 06H 0EH 020. PICTURE MUTE OFF Function: This command cancels the blank picture...
... the time of a success 22H 10H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 03H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * When switch to the Video connector 02H 03H 00H 00H 02H 01H 06H 0EH 020. PICTURE MUTE OFF Function: This command cancels the blank picture...
RS232 codes- Projectors
Page 27
... DATA01 .. 02 Results 0000H : Normal 0000H Other : Error Response: At the time of a failure A3H 10H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * Setting the Aspect Ratio to Letter Box (Wide Zoom) 03H 10H 00H 00H 05H 18H 00H 00H 01H 00H 31H (!) Method of Specifying the Absolute... Value of a failure A3H 10H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * Setting Volume to "10" 03H 10H 00H 00H 05H 05H 00H 00H 0AH 00H 27H 030-12. Command: 03H 10H 00H 00H 05H DATA01 .. IMAGE...
... DATA01 .. 02 Results 0000H : Normal 0000H Other : Error Response: At the time of a failure A3H 10H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * Setting the Aspect Ratio to Letter Box (Wide Zoom) 03H 10H 00H 00H 05H 18H 00H 00H 01H 00H 31H (!) Method of Specifying the Absolute... Value of a failure A3H 10H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * Setting Volume to "10" 03H 10H 00H 00H 05H 05H 00H 00H 0AH 00H 27H 030-12. Command: 03H 10H 00H 00H 05H DATA01 .. IMAGE...
RS232 codes- Projectors
Page 29
value will change to 5400000 seconds * The projector's hours of use is displayed in terms of Normal mode values. Lamp Timer Acquisition Examples DATA83 DATA84 DATA85 DATA86 : Lamp Timer 00H 00H 00H 00H : Total 0 seconds C0H 65H 52H 00H : Total 5400000 seconds/3600 = ...16 : Lamp Use Prohibited Time(Normal mode) (second) Response: At the time of a failure A3H 8CH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: Example for acquiring remaining lamp time (in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to Decimal - Command: 03H 8CH 00H 00H 00H 8FH Response: At...
value will change to 5400000 seconds * The projector's hours of use is displayed in terms of Normal mode values. Lamp Timer Acquisition Examples DATA83 DATA84 DATA85 DATA86 : Lamp Timer 00H 00H 00H 00H : Total 0 seconds C0H 65H 52H 00H : Total 5400000 seconds/3600 = ...16 : Lamp Use Prohibited Time(Normal mode) (second) Response: At the time of a failure A3H 8CH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: Example for acquiring remaining lamp time (in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to Decimal - Command: 03H 8CH 00H 00H 00H 8FH Response: At...
RS232 codes- Projectors
Page 31
...xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * In case of acquiring lamp's use of hours 03H 96H 00H 00H 02H 00H 01H 9CH Example of acquisition DATA03 DATA04 DATA05 DATA06: lamp's use of hours = 18000/3600 = 5 hours * In case of acquiring the remaining time until lamp warning...360000 seconds Remaining time until lamp warning message starts to appear (in terms of specified values) 03H 96H 00H 00H 02H 00H 08H A3H Example of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to 18000 seconds Lamp's...
...xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * In case of acquiring lamp's use of hours 03H 96H 00H 00H 02H 00H 01H 9CH Example of acquisition DATA03 DATA04 DATA05 DATA06: lamp's use of hours = 18000/3600 = 5 hours * In case of acquiring the remaining time until lamp warning...360000 seconds Remaining time until lamp warning message starts to appear (in terms of specified values) 03H 96H 00H 00H 02H 00H 08H A3H Example of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to 18000 seconds Lamp's...
RS232 codes- Projectors
Page 32
... 9BH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * In case of acquiring lamp's use of hours 03H 9BH 00H 00H 03H 00H 00H 01H CKS Example of acquisition DATA04 DATA05 DATA06 DATA07 : lamp's use of hours 50H 46H 00H 00H : 18000 seconds Lamp Usage = 18000 / 3600 = 5 hour 037-7.
... 9BH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * In case of acquiring lamp's use of hours 03H 9BH 00H 00H 03H 00H 00H 01H CKS Example of acquisition DATA04 DATA05 DATA06 DATA07 : lamp's use of hours 50H 46H 00H 00H : 18000 seconds Lamp Usage = 18000 / 3600 = 5 hour 037-7.
RS232 codes- Projectors
Page 33
... mode of a success 23H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents (!1) X = 100 - ((Lamp Use Prohibited Time * 100) / Lamp Use Warning Starting Time) Example) The case of Lamp Use Prohibited Time 2100[H] A Lamp Use Warning Starting Time 2000[H] Model.
... mode of a success 23H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents (!1) X = 100 - ((Lamp Use Prohibited Time * 100) / Lamp Use Warning Starting Time) Example) The case of Lamp Use Prohibited Time 2100[H] A Lamp Use Warning Starting Time 2000[H] Model.
RS232 codes- Projectors
Page 35
... 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents Response At the time of a success( ACK ) This returns ACK without adding data portion to return it. (Example) Power On Command: 02H 00H 00H 00H 00H CKS Response: A2H 00H 01H 40H 02H DATA01 DATA02 CKS 7. Specified terminal is unavailable or cannot be...
... 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents Response At the time of a success( ACK ) This returns ACK without adding data portion to return it. (Example) Power On Command: 02H 00H 00H 00H 00H CKS Response: A2H 00H 01H 40H 02H DATA01 DATA02 CKS 7. Specified terminal is unavailable or cannot be...
RS232 codes- Projectors
Page 38
Command example: * Sending the AUTO key code 02H 0FH 00H 00H 02H 05H 00H 18H * Sending the AUTO (SHORT) key code 02H 0FH 00H 00H 02H DDH ...
Command example: * Sending the AUTO key code 02H 0FH 00H 00H 02H 05H 00H 18H * Sending the AUTO (SHORT) key code 02H 0FH 00H 00H 02H DDH ...
RS232 codes- Projectors
Page 39
...[kg]) DATA06 to 09 Carbon Savings (Milligram Maximum:999999[mg]) Response: At the time of a failure A3H 9AH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: Example for Total Carbon Savings DATA02 DATA03 DATA04 DATA05 : Kilogram 9CH 09H 00H 00H : 2460 [kg] DATA06 DATA07 DATA08 DATA09 : Milligram 06H F9H 00H 00H : 63750...
...[kg]) DATA06 to 09 Carbon Savings (Milligram Maximum:999999[mg]) Response: At the time of a failure A3H 9AH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: Example for Total Carbon Savings DATA02 DATA03 DATA04 DATA05 : Kilogram 9CH 09H 00H 00H : 2460 [kg] DATA06 DATA07 DATA08 DATA09 : Milligram 06H F9H 00H 00H : 63750...
RS232 codes- Projectors
Page 42
... 91H 00H SweetVision Mode 92H 00H SweetVision Level 94H 00H Vertical Enhancer 95H 00H I/P Converter 96H 00H Lamp Mode Adjust 97H 00H Wall Color Command example: * In case of acquiring Picture Brightness 03H 04H 00H 00H 03H 00H 00H 00H 0AH Dual / Contrast B 00H White Bal. Lamp1 / Contrast B 00H White Bal...
... 91H 00H SweetVision Mode 92H 00H SweetVision Level 94H 00H Vertical Enhancer 95H 00H I/P Converter 96H 00H Lamp Mode Adjust 97H 00H Wall Color Command example: * In case of acquiring Picture Brightness 03H 04H 00H 00H 03H 00H 00H 00H 0AH Dual / Contrast B 00H White Bal. Lamp1 / Contrast B 00H White Bal...
RS232 codes- Projectors
Page 56
... for the command that does not request data. 6.1. Response At the time of a success (ACK) This returns ACK without adding data portion to return it. (Example) Power On Command: 02H 00H FFH F0H 00H CKS NAK: A2H 00H 01H 20H 02H DATA01 DATA02 CKS 6. Data Portion of not accepting the command...
... for the command that does not request data. 6.1. Response At the time of a success (ACK) This returns ACK without adding data portion to return it. (Example) Power On Command: 02H 00H FFH F0H 00H CKS NAK: A2H 00H 01H 20H 02H DATA01 DATA02 CKS 6. Data Portion of not accepting the command...