M4300 FAQs
Page 1
...bays XSM4396K0 - Model Name Model Number 10GBASE-T RJ45 1G/10G SFP+ 40G QSFP+ Form Factor Rack Mount Power Supply Included PSU M4300-8X8F XSM4316S 8 ports 8 ports M4300-12X12F XSM4324S 12 ports 12 ports Half-width 1- as standard. or 2-unit 1U Modular 1 bay Fans Noise @25°C 36....enterprise edge and SMB core with unrivalled ease of Rack installations. Perfect for wireless access, unified communications and IP video, the NETGEAR M4300 Switch Series is also ready for your network. 2. Layer 3 feature set includes static and policy-based routing, RIP, VRRP, OSPF, and ...
...bays XSM4396K0 - Model Name Model Number 10GBASE-T RJ45 1G/10G SFP+ 40G QSFP+ Form Factor Rack Mount Power Supply Included PSU M4300-8X8F XSM4316S 8 ports 8 ports M4300-12X12F XSM4324S 12 ports 12 ports Half-width 1- as standard. or 2-unit 1U Modular 1 bay Fans Noise @25°C 36....enterprise edge and SMB core with unrivalled ease of Rack installations. Perfect for wireless access, unified communications and IP video, the NETGEAR M4300 Switch Series is also ready for your network. 2. Layer 3 feature set includes static and policy-based routing, RIP, VRRP, OSPF, and ...
M4300 FAQs
Page 2
... DAC passive/active cables if they are as well. To install a single half-width switch in shared EPS mode. 8. As a new member of the M4300 Layer 3 Stackable Family, the NETGEAR M4300-96X is removed from this slot untouched in this slot, but please note that the ...96X allows for granularity between copper and fiber and headroom for organizations who buy infrastructure for stacking on M4300-8X8F, M4300-12X12F, M4300-24X24F, M4300-96X, M4300-28G, M4300-52G, M430028G-PoE+ and M4300-52G-PoE+ models. PoE over 10G is operational in a single rack space, you can deliver power...
... DAC passive/active cables if they are as well. To install a single half-width switch in shared EPS mode. 8. As a new member of the M4300 Layer 3 Stackable Family, the NETGEAR M4300-96X is removed from this slot untouched in this slot, but please note that the ...96X allows for granularity between copper and fiber and headroom for organizations who buy infrastructure for stacking on M4300-8X8F, M4300-12X12F, M4300-24X24F, M4300-96X, M4300-28G, M4300-52G, M430028G-PoE+ and M4300-52G-PoE+ models. PoE over 10G is operational in a single rack space, you can deliver power...
M4300 FAQs
Page 3
...-effective at the edge, with built-in 10GBASE-T and SFP+ fiber uplinks and no hidden costs •While any switch to switch interconnect in M4300 stack. • Centralized power management system with N+1 power redundancy at the edge and bring network resiliency with 80G half..., or dual ring topologies greatly simplify deployments at the chassis level (one redundant PSU for the entire chassis, when M4300 switches require one redundant PSU per switch) • Modular and redundant architecture with everlasting passive backplane and highly reliable fabric-based design • Modular PoE+...
...-effective at the edge, with built-in 10GBASE-T and SFP+ fiber uplinks and no hidden costs •While any switch to switch interconnect in M4300 stack. • Centralized power management system with N+1 power redundancy at the edge and bring network resiliency with 80G half..., or dual ring topologies greatly simplify deployments at the chassis level (one redundant PSU for the entire chassis, when M4300 switches require one redundant PSU per switch) • Modular and redundant architecture with everlasting passive backplane and highly reliable fabric-based design • Modular PoE+...
M4300 FAQs
Page 4
... of failure for servers and storage equipment •All devices can be used for stacking, depending on inter-switch links oversubscription requirements •Up to (8) M4300 switches can connect to both the management unit and the backup unit connect to the core using distributed link aggregation ...and out, while backup unit guarantees connectivity to the core •Back to two different M4300 switches in a single rack space for instance, will continue to flow through the other switches when the management unit fails - all other link without NSF and hitless failover •Back...
... of failure for servers and storage equipment •All devices can be used for stacking, depending on inter-switch links oversubscription requirements •Up to (8) M4300 switches can connect to both the management unit and the backup unit connect to the core using distributed link aggregation ...and out, while backup unit guarantees connectivity to the core •Back to two different M4300 switches in a single rack space for instance, will continue to flow through the other switches when the management unit fails - all other link without NSF and hitless failover •Back...
M4300 FAQs
Page 5
...MTP, RSTP; MAB; Single Rate Policing • IPv4/IPv6 Multicast Filtering: IGMPv3 MLDv2 Snooping and Proxy ASM & SSM; M4300 OpenFlow feature enables the switch to be managed by a centralized OpenFlow Controller using the OpenFlow protocol. •Support of the OpenFlow 1.3 • It ...with low acoustics for active-active server and storage connections across two switches in a stack: when the management unit fails, most competitive solutions, up and maintain SSL connections with the OpenFlow Controllers •M4300 implements a subset of the OpenFlow 1.0.0 protocol and a subset ...
...MTP, RSTP; MAB; Single Rate Policing • IPv4/IPv6 Multicast Filtering: IGMPv3 MLDv2 Snooping and Proxy ASM & SSM; M4300 OpenFlow feature enables the switch to be managed by a centralized OpenFlow Controller using the OpenFlow protocol. •Support of the OpenFlow 1.3 • It ...with low acoustics for active-active server and storage connections across two switches in a stack: when the management unit fails, most competitive solutions, up and maintain SSL connections with the OpenFlow Controllers •M4300 implements a subset of the OpenFlow 1.0.0 protocol and a subset ...
M4300 FAQs
Page 6
... Technology, Inc. Mini-USB console port allows user to directly access M4300 switch using XMODEM serial port protocol for Windows Server 2008; Windows 10; Windows 7; Windows Vista x64; Yes, M4300 Switch provides the admin with the switch, either from the CD that case. NETGEAR, the NETGEAR logo and ProSAFE are active simultaneously. HPE is a registered trademark of...
... Technology, Inc. Mini-USB console port allows user to directly access M4300 switch using XMODEM serial port protocol for Windows Server 2008; Windows 10; Windows 7; Windows Vista x64; Yes, M4300 Switch provides the admin with the switch, either from the CD that case. NETGEAR, the NETGEAR logo and ProSAFE are active simultaneously. HPE is a registered trademark of...
CLI Manual Software Version 12.x
Page 1
CLI Command Reference Manual M4300 Intelligent Edge Series Fully Managed Stackable Switches Software Version 12.0.11 and Earlier Versions M4300 Series Switches M4300-96X Modular Switch May 2020 202-11997-03 NETGEAR, Inc. 350 East Plumeria Drive San Jose, CA 95134, USA
CLI Command Reference Manual M4300 Intelligent Edge Series Fully Managed Stackable Switches Software Version 12.0.11 and Earlier Versions M4300 Series Switches M4300-96X Modular Switch May 2020 202-11997-03 NETGEAR, Inc. 350 East Plumeria Drive San Jose, CA 95134, USA
CLI Manual Software Version 12.x
Page 2
If you do not agree, return the device to your place of NETGEAR, Inc. M4300 Intelligent Edge Series Fully Managed Stackable Switches Support and Community Visit netgear.com/support to get your return period. Trademarks © NETGEAR, Inc., NETGEAR, and the NETGEAR Logo are trademarks of purchase within your questions answered and access the latest downloads. By using...
If you do not agree, return the device to your place of NETGEAR, Inc. M4300 Intelligent Edge Series Fully Managed Stackable Switches Support and Community Visit netgear.com/support to get your return period. Trademarks © NETGEAR, Inc., NETGEAR, and the NETGEAR Logo are trademarks of purchase within your questions answered and access the latest downloads. By using...
CLI Manual Software Version 12.x
Page 3
... on page 646. • Added load-interval on page 777. • Removed references to SSH-1 Rivest-Shamir-Adelman (RSA) throughout the manual. M4300 Intelligent Edge Series Fully Managed Stackable Switches 202-11997-02 202-11997-01 202-11814-03 202-11814-02 202-11814-01 December 2019 September 2019 October 2018 June...
... on page 646. • Added load-interval on page 777. • Removed references to SSH-1 Rivest-Shamir-Adelman (RSA) throughout the manual. M4300 Intelligent Edge Series Fully Managed Stackable Switches 202-11997-02 202-11997-01 202-11814-03 202-11814-02 202-11814-01 December 2019 September 2019 October 2018 June...
CLI Manual Software Version 12.x
Page 4
Contents Chapter 1 About the Managed Switch Software Scope 10 Product Concept 10 Chapter 2 Using the Command-Line Interface Command Syntax 12 Command Conventions 12 Common Parameter Values 13 unit/slot/port ... Port Stacking Commands 28 Stack Port Commands 40 Stack Firmware Synchronization Commands 47 Nonstop Forwarding Commands for Stack Configuration 48 Chapter 5 Management Commands Configure the Switch Management CPU 54 CPU Queue Commands 57 Management Interface Commands 58 IPv6 Management Commands 65 Console Port Access Commands 70 Telnet Commands 72 Secure Shell...
Contents Chapter 1 About the Managed Switch Software Scope 10 Product Concept 10 Chapter 2 Using the Command-Line Interface Command Syntax 12 Command Conventions 12 Common Parameter Values 13 unit/slot/port ... Port Stacking Commands 28 Stack Port Commands 40 Stack Firmware Synchronization Commands 47 Nonstop Forwarding Commands for Stack Configuration 48 Chapter 5 Management Commands Configure the Switch Management CPU 54 CPU Queue Commands 57 Management Interface Commands 58 IPv6 Management Commands 65 Console Port Access Commands 70 Telnet Commands 72 Secure Shell...
CLI Manual Software Version 12.x
Page 5
M4300 Intelligent Edge Series Fully Managed Stackable Switches Hypertext Transfer Protocol Commands 85 Access Commands 93 User Account Commands 94 Per-Command Authorization 99 Exec Authorization 99 SNMP Commands 126 RADIUS Commands...Application Commands 180 Chapter 6 Utility Commands AutoInstall Commands 184 CLI Output Filtering Commands 188 Dual Image Commands 190 System Information and Statistics Commands 191 Switch Services Commands 220 Logging Commands 223 Email Alerting and Mail Server Commands 231 System Utility and Clear Commands 237 Simple Network Time Protocol Commands ...
M4300 Intelligent Edge Series Fully Managed Stackable Switches Hypertext Transfer Protocol Commands 85 Access Commands 93 User Account Commands 94 Per-Command Authorization 99 Exec Authorization 99 SNMP Commands 126 RADIUS Commands...Application Commands 180 Chapter 6 Utility Commands AutoInstall Commands 184 CLI Output Filtering Commands 188 Dual Image Commands 190 System Information and Statistics Commands 191 Switch Services Commands 220 Logging Commands 223 Email Alerting and Mail Server Commands 231 System Utility and Clear Commands 237 Simple Network Time Protocol Commands ...
CLI Manual Software Version 12.x
Page 6
M4300 Intelligent Edge Series Fully Managed Stackable Switches VLAN Commands 417 Switch Port Commands 429 Double VLAN Commands 433 Private VLAN Commands 437 Voice VLAN Commands 439 Precision Time Protocol Commands 443 Provisioning (IEEE 802.1p) Commands ...
M4300 Intelligent Edge Series Fully Managed Stackable Switches VLAN Commands 417 Switch Port Commands 429 Double VLAN Commands 433 Private VLAN Commands 437 Voice VLAN Commands 439 Precision Time Protocol Commands 443 Provisioning (IEEE 802.1p) Commands ...
CLI Manual Software Version 12.x
Page 7
M4300 Intelligent Edge Series Fully Managed Stackable Switches Routing Policy Commands 682 Router Discovery Protocol Commands 692 Virtual LAN Routing Commands 696 Virtual Router Redundancy Protocol Commands 699 DHCP and BootP Relay Commands ...
M4300 Intelligent Edge Series Fully Managed Stackable Switches Routing Policy Commands 682 Router Discovery Protocol Commands 692 Virtual LAN Routing Commands 696 Virtual Router Redundancy Protocol Commands 699 DHCP and BootP Relay Commands ...
CLI Manual Software Version 12.x
Page 8
M4300 Intelligent Edge Series Fully Managed Stackable Switches IP Access Control List Commands 965 IPv6 Access Control List Commands 981 Time Range Commands for Time-Based ACLs 990 Auto-Voice over IP Commands ... Commands 1076 IPv6 MLD-Proxy Commands 1084 Chapter 15 Power over Ethernet Commands About PoE 1091 PoE Commands 1091 Chapter 16 Switch Software Log Messages Core 1103 Utilities 1105 Management 1108 Switching 1112 QoS 1119 Routing/IPv6 Routing 1120 Multicast 1123 Stacking 1128 Technologies 1128 O/S Support 1131 Chapter 17 Command List 8 CLI...
M4300 Intelligent Edge Series Fully Managed Stackable Switches IP Access Control List Commands 965 IPv6 Access Control List Commands 981 Time Range Commands for Time-Based ACLs 990 Auto-Voice over IP Commands ... Commands 1076 IPv6 MLD-Proxy Commands 1084 Chapter 15 Power over Ethernet Commands About PoE 1091 PoE Commands 1091 Chapter 16 Switch Software Log Messages Core 1103 Utilities 1105 Management 1108 Switching 1112 QoS 1119 Routing/IPv6 Routing 1120 Multicast 1123 Stacking 1128 Technologies 1128 O/S Support 1131 Chapter 17 Command List 8 CLI...
CLI Manual Software Version 12.x
Page 9
... network administrator. Note: For switch documentation, visit netgear.com/support/product/m4300.aspx#docs and netgear.com/support/product/M4300-96X.aspx#docs. Some products can check for the M4300 Intelligent Edge Series Fully Managed Stackable Switches and covers all M4300 switch models and modular model M4300-96X. If the features or behavior of the NETGEAR managed switch software, in this manual...
... network administrator. Note: For switch documentation, visit netgear.com/support/product/m4300.aspx#docs and netgear.com/support/product/M4300-96X.aspx#docs. Some products can check for the M4300 Intelligent Edge Series Fully Managed Stackable Switches and covers all M4300 switch models and modular model M4300-96X. If the features or behavior of the NETGEAR managed switch software, in this manual...
CLI Manual Software Version 12.x
Page 10
M4300 Intelligent Edge Series Fully Managed Stackable Switches Scope The NETGEAR managed switch software encompasses both the software and the network. This code is designed to run in frame forwarding, as needed and specified. The NETGEAR managed switch software includes a set of the following processors: • CPU. You can manage the NETGEAR managed switch...from high-end backbone applications to improve. This code is partitioned to run on which the NETGEAR managed switch software runs varies depending upon the platform. It also assists in the following three methods: ...
M4300 Intelligent Edge Series Fully Managed Stackable Switches Scope The NETGEAR managed switch software encompasses both the software and the network. This code is designed to run in frame forwarding, as needed and specified. The NETGEAR managed switch software includes a set of the following processors: • CPU. You can manage the NETGEAR managed switch...from high-end backbone applications to improve. This code is partitioned to run on which the NETGEAR managed switch software runs varies depending upon the platform. It also assists in the following three methods: ...
CLI Manual Software Version 12.x
Page 12
...] is the command name. • ipaddr and netmask are parameters and represent required values that the command shows. Indicates an optional parameter. M4300 Intelligent Edge Series Fully Managed Stackable Switches Command Syntax A command is one or more words that you supply a value after you are not required to enter a value in to...
...] is the command name. • ipaddr and netmask are parameters and represent required values that the command shows. Indicates an optional parameter. M4300 Intelligent Edge Series Fully Managed Stackable Switches Command Syntax A command is one or more words that you supply a value after you are not required to enter a value in to...
CLI Manual Software Version 12.x
Page 13
... CLI Command Reference Manual Parameter Descriptions Parameter ipaddr ipv6-addr Interface or unit/slot/port Description This parameter is a valid IPv6 address. M4300 Intelligent Edge Series Fully Managed Stackable Switches Table 1. This square brackets format is used mainly for complicated commands Common Parameter Values Parameter values might be names (strings) or numbers...
... CLI Command Reference Manual Parameter Descriptions Parameter ipaddr ipv6-addr Interface or unit/slot/port Description This parameter is a valid IPv6 address. M4300 Intelligent Edge Series Fully Managed Stackable Switches Table 1. This square brackets format is used mainly for complicated commands Common Parameter Values Parameter values might be names (strings) or numbers...
CLI Manual Software Version 12.x
Page 14
...the logical slots. The interface number consists of slots Slot Type Description Physical slot numbers for a switch is 1/0/1, port 2 is M4300-96X 1/0/2, port 3 is not valid. switch models except for model Physical slot numbers are numbered sequentially starting from 1 to identify certain logical ... marks to identify character strings, for number of logical interface and can use the logical unit/slot/port to the maximum M4300 switch models except for example, "System Name with zero, and are Gigabit Ethernet or multispeed 10G Ethernet. The slot number has...
...the logical slots. The interface number consists of slots Slot Type Description Physical slot numbers for a switch is 1/0/1, port 2 is M4300-96X 1/0/2, port 3 is not valid. switch models except for model Physical slot numbers are numbered sequentially starting from 1 to identify certain logical ... marks to identify character strings, for number of logical interface and can use the logical unit/slot/port to the maximum M4300 switch models except for example, "System Name with zero, and are Gigabit Ethernet or multispeed 10G Ethernet. The slot number has...
CLI Manual Software Version 12.x
Page 15
... display to find the information the user is disabled by the driver as one or more physical entities located on physical slots. M4300 Intelligent Edge Series Fully Managed Stackable Switches Table 4. Types of a command or reset a value back to reverse the action of ports Port Type Logical Interfaces CPU ports Description Port...
... display to find the information the user is disabled by the driver as one or more physical entities located on physical slots. M4300 Intelligent Edge Series Fully Managed Stackable Switches Table 4. Types of a command or reset a value back to reverse the action of ports Port Type Logical Interfaces CPU ports Description Port...