Datasheet
Page 1
...Theater Power Conditioners by an A/V component can not contaminate the power going to its full capability. 2 Monitors Incoming Line Voltage Panamax's patent pending AVM circuitry continuously monitors the incoming line voltage and disconnects your equipment in the event of detail, pops, ...calls or system downtime. 3 Reduces Cross-Contamination Between Components The M4300-EX is designed to provide noise isolation between 2 isolated outlet banks including 1 high current outlet so that any noise created by Panamax MAX® 4300-EX THE SOURCE OF PURE SOUND AND PICTURE™ TOP BENEFITS ...
...Theater Power Conditioners by an A/V component can not contaminate the power going to its full capability. 2 Monitors Incoming Line Voltage Panamax's patent pending AVM circuitry continuously monitors the incoming line voltage and disconnects your equipment in the event of detail, pops, ...calls or system downtime. 3 Reduces Cross-Contamination Between Components The M4300-EX is designed to provide noise isolation between 2 isolated outlet banks including 1 high current outlet so that any noise created by Panamax MAX® 4300-EX THE SOURCE OF PURE SOUND AND PICTURE™ TOP BENEFITS ...
Datasheet
Page 2
...-5900 • Fax - 707-283-5901 • www.panamax.com ® © 2006 Panamax, Inc. UPC's, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING MODEL M4300-EX UNIT CARTON MASTER CARTON Dimensions Weight Dimensions Weight UPC Qty Dimensions ...Weight 17" x 7.25" x 1.75" 2.125" H with separate ground leads. Protect or Disconnect is a trademark of Teccor Electronics, Inc. Outlet Bank...
...-5900 • Fax - 707-283-5901 • www.panamax.com ® © 2006 Panamax, Inc. UPC's, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING MODEL M4300-EX UNIT CARTON MASTER CARTON Dimensions Weight Dimensions Weight UPC Qty Dimensions ...Weight 17" x 7.25" x 1.75" 2.125" H with separate ground leads. Protect or Disconnect is a trademark of Teccor Electronics, Inc. Outlet Bank...
Manual
Page 1
... is provided for reliability and unsurpassed protection. just 1 volt above normal operating levels. Model: M4300-EX M4300-EX BANK 1 ALWAYS ON BANK 2 ON WIRING OK UNSAFE VOLTAGE POWER AND FILTRATION Home Theater Power Conditioner Key Features Automatic Over & Under Voltage Protection: Panamax's patent pending power monitoring circuitry constantly monitors the AC line voltage for TV show scheduling...
... is provided for reliability and unsurpassed protection. just 1 volt above normal operating levels. Model: M4300-EX M4300-EX BANK 1 ALWAYS ON BANK 2 ON WIRING OK UNSAFE VOLTAGE POWER AND FILTRATION Home Theater Power Conditioner Key Features Automatic Over & Under Voltage Protection: Panamax's patent pending power monitoring circuitry constantly monitors the AC line voltage for TV show scheduling...
Manual
Page 2
... Clamping Level 1.4V Attenuation 1db up to product upgrades and improvements. www.panamax.com Customer Relations 7:30 AM - 4:30 PM, M-F Email - Protect or Disconnect and SignalPerfect are registered US trademarks of Panamax. M4300-EX Specifications AC Power Line Voltage 120V, 60Hz Total Current Capacity 15 A UL1449...VAC ±5 VAC Under-voltage shutoff 84 VAC ± 6 VAC EMI/RFI Noise Filtration Bank 1, High Current Outlet 49 db, 100 KHz - 2 MHz Bank 1, Always ON Outlets 61 db, 100 KHz - 2 MHz Bank 2, Switched Outlets 60 db, 100 KHz - 2 MHz LAN Circuit Clamping Level 8V ±...
... Clamping Level 1.4V Attenuation 1db up to product upgrades and improvements. www.panamax.com Customer Relations 7:30 AM - 4:30 PM, M-F Email - Protect or Disconnect and SignalPerfect are registered US trademarks of Panamax. M4300-EX Specifications AC Power Line Voltage 120V, 60Hz Total Current Capacity 15 A UL1449...VAC ±5 VAC Under-voltage shutoff 84 VAC ± 6 VAC EMI/RFI Noise Filtration Bank 1, High Current Outlet 49 db, 100 KHz - 2 MHz Bank 1, Always ON Outlets 61 db, 100 KHz - 2 MHz Bank 2, Switched Outlets 60 db, 100 KHz - 2 MHz LAN Circuit Clamping Level 8V ±...
Manual
Page 3
...Features Power Button Press and hold for satellite TV signal lines. Unsafe Voltage Indicator Normally Off. Home Theater Power Conditioner M4300 -EX Back Panel Connection Features Circuit Breaker Automatically opens when the current load is provided by a two stage tapped Pi filter ... noise filtration circuit that the wall outlet is properly grounded and Line/Neutral polarity is cleaned by the front panel Power Button. M4300-EX BANK 1 ALWAYS ON BANK 2 ON POWER AND FILTRATION WIRING OK UNSAFE VOLTAGE Wiring OK LED Normally On. Its output is provided to call attention to your...
...Features Power Button Press and hold for satellite TV signal lines. Unsafe Voltage Indicator Normally Off. Home Theater Power Conditioner M4300 -EX Back Panel Connection Features Circuit Breaker Automatically opens when the current load is provided by a two stage tapped Pi filter ... noise filtration circuit that the wall outlet is properly grounded and Line/Neutral polarity is cleaned by the front panel Power Button. M4300-EX BANK 1 ALWAYS ON BANK 2 ON POWER AND FILTRATION WIRING OK UNSAFE VOLTAGE Wiring OK LED Normally On. Its output is provided to call attention to your...