Quick Installation Guide
Page 7
3. Gigabit + Ethernet / Network Port Reset Button Sync Note: Please refer to the User's Guide on the TPL-401E/TPL-401E2K's User's Guide CD for detailed explanations of the device. LEDs and Buttons PWR (Power) ETH (Ethernet Link/ACT) PL (Powerline) The Gigabit Ethernet/Network Port and Reset buttton are located at the bottom of each LED and button. 5
3. Gigabit + Ethernet / Network Port Reset Button Sync Note: Please refer to the User's Guide on the TPL-401E/TPL-401E2K's User's Guide CD for detailed explanations of the device. LEDs and Buttons PWR (Power) ETH (Ethernet Link/ACT) PL (Powerline) The Gigabit Ethernet/Network Port and Reset buttton are located at the bottom of each LED and button. 5
Quick Installation Guide
Page 8
... my Powerline devices on my Powerline network, but I cannot connect to factory default. Check both of the TPL-401E adapter is located on . 2. Go into the outlet, then repeat the reset procedure. 2. Troubleshooting 1. What should I do ? 1.Verify that the Powerline network is connected to establish ...connectivity after performing the above steps, please reset both TPL-401E and the router's network port LED for positive connection status. 3. Make sure your Router is connected to the TPL-401E's network port). The LEDs will become solid when the ...
... my Powerline devices on my Powerline network, but I cannot connect to factory default. Check both of the TPL-401E adapter is located on . 2. Go into the outlet, then repeat the reset procedure. 2. Troubleshooting 1. What should I do ? 1.Verify that the Powerline network is connected to establish ...connectivity after performing the above steps, please reset both TPL-401E and the router's network port LED for positive connection status. 3. Make sure your Router is connected to the TPL-401E's network port). The LEDs will become solid when the ...
Quick Installation Guide
Page 9
Click Internet Protocol (TCP/IP) and then click Properties. No, the TPL-401E adapter should automatically establish connection once both units are reset to the User's Guide included on the Utility CD-ROM or contact TRENDnet's Technical Support Department. 7 Go into the Control Panel, double-click the Network Connections icon and then right-click...
Click Internet Protocol (TCP/IP) and then click Properties. No, the TPL-401E adapter should automatically establish connection once both units are reset to the User's Guide included on the Utility CD-ROM or contact TRENDnet's Technical Support Department. 7 Go into the Control Panel, double-click the Network Connections icon and then right-click...
Data Sheet
Page 2
... of their respective holders. For the most recent product information please visit http://www.trendnet.com. All Rights Reserved. 500Mbps Powerline AV Adapter Kit TPL-401E2K (V1.0R) SPECIFICATIONS Hardware Standards Interface Frequency Band Modulation Protocols Speed Utility OS Compatibility...Better (Amber) • Good (Red) • Sync, Reset • A: 98 x 72 x 55 mm (3.9 x 2.8 x 2.2 in.) • EU: 98 x 72 x 70 mm (3.9 x 2.8 x 2.8 in this document pertain to change at any time, without notice. Copyright © TRENDnet. QAM, QPSK, BPSK, ROBO Carrier • TDMA and CSMA...
... of their respective holders. For the most recent product information please visit http://www.trendnet.com. All Rights Reserved. 500Mbps Powerline AV Adapter Kit TPL-401E2K (V1.0R) SPECIFICATIONS Hardware Standards Interface Frequency Band Modulation Protocols Speed Utility OS Compatibility...Better (Amber) • Good (Red) • Sync, Reset • A: 98 x 72 x 55 mm (3.9 x 2.8 x 2.2 in.) • EU: 98 x 72 x 70 mm (3.9 x 2.8 x 2.8 in this document pertain to change at any time, without notice. Copyright © TRENDnet. QAM, QPSK, BPSK, ROBO Carrier • TDMA and CSMA...
User's Guide
Page 6
... the factory default private network name "HomePlugAV" Erases the network name/key (All LEDs will turn off and turn back on) Reset device to factory defaults (All LEDs will start blinking) Match network name/key on secondary or additional adapter and connect to first adapter. (PWR LED ... (120 sec) of pushing the Sync button of the device. 1.6 Ethernet Port There is one RJ-45 10/100/1000Mbps Auto-MDIX Gigabit Ethernet port, Reset Button, and Sync Button located at the bottom of the first adapter in order to establish connectivity.
... the factory default private network name "HomePlugAV" Erases the network name/key (All LEDs will turn off and turn back on) Reset device to factory defaults (All LEDs will start blinking) Match network name/key on secondary or additional adapter and connect to first adapter. (PWR LED ... (120 sec) of pushing the Sync button of the device. 1.6 Ethernet Port There is one RJ-45 10/100/1000Mbps Auto-MDIX Gigabit Ethernet port, Reset Button, and Sync Button located at the bottom of the first adapter in order to establish connectivity.
User's Guide
Page 19
... are noise sources on the electrical and can obtain better connection quality. Use a pin or paperclip and push and hold the Reset button for 1 second on . The Power (PWR) LED will flash every 15 seconds to indicate that the device is red indicating good...boxes, and then connect an Ethernet cable between different circuit breaker boxes. This will reset the TPL-401E powerline adapters to the default settings, network name/security key assignment "HomePlugAV". The TPL-401E can provide better connectivity and performance when plugged directly into another available wall ...
... are noise sources on the electrical and can obtain better connection quality. Use a pin or paperclip and push and hold the Reset button for 1 second on . The Power (PWR) LED will flash every 15 seconds to indicate that the device is red indicating good...boxes, and then connect an Ethernet cable between different circuit breaker boxes. This will reset the TPL-401E powerline adapters to the default settings, network name/security key assignment "HomePlugAV". The TPL-401E can provide better connectivity and performance when plugged directly into another available wall ...
User's Guide
Page 20
... Standard) LED Buttons Power (PWR), Ethernet Link/Act (ETH) Powerline (PL) with Connection Quality Indication Best (Green) Better (Amber) Good (Red) Sync, Reset Dimension (L x W X H) A: 98 x 72 x 55 mm (3.9 x 2.8 x 2.2 in.) per unit EU: 98 x 72 x 70 mm (3.9 x 2.8 x 2.8 in.) per unit Weight A: Total Weight: 300 g (10.6 oz) / Per Unit Weight...
... Standard) LED Buttons Power (PWR), Ethernet Link/Act (ETH) Powerline (PL) with Connection Quality Indication Best (Green) Better (Amber) Good (Red) Sync, Reset Dimension (L x W X H) A: 98 x 72 x 55 mm (3.9 x 2.8 x 2.2 in.) per unit EU: 98 x 72 x 70 mm (3.9 x 2.8 x 2.8 in.) per unit Weight A: Total Weight: 300 g (10.6 oz) / Per Unit Weight...