Design Guide - Electric Cooktops
Page 4
...mm) minimum. This distance can choose models with our exclusive Sensor Dome™ system which monitors the temperature of a Thermador Ventilation System with mechanical controls and touch controls in this appliance must comply with all applicable local codes. Solid surface countertops... for complete details before installing. Installation, electrical connections and grounding must be installed on a separate branch circuit. mODeL CEM304FS CES304FS CET304FS CEM365FS CES365FS CES366FS CET366FS reQuIreD CIrCuIT breAKer 240V, 3 Wire, 60 Hz 208V, 3 Wire, 60 Hz 40 Amp 30...
...mm) minimum. This distance can choose models with our exclusive Sensor Dome™ system which monitors the temperature of a Thermador Ventilation System with mechanical controls and touch controls in this appliance must comply with all applicable local codes. Solid surface countertops... for complete details before installing. Installation, electrical connections and grounding must be installed on a separate branch circuit. mODeL CEM304FS CES304FS CET304FS CEM365FS CES365FS CES366FS CET366FS reQuIreD CIrCuIT breAKer 240V, 3 Wire, 60 Hz 208V, 3 Wire, 60 Hz 40 Amp 30...
Design Guide - Electric Cooktops
Page 5
... Wall Left Front Element Right Front Element Left Rear Element Right Rear Element Center Element Electrical Supply Required Circuit Breaker Conduit Shipping Weight (lbs.) CEM304FS CET304FS 4 31" 21 1/4" 28 3/4" - 28 7/8" 3 15/16" 1/4" 19 7/8" - 20" 2 1/4" 2 3/4" 6" @ 1,200W 7" @ 1,800W 5" / 7" @ 700 / 1,700 W 6" / 9" @ 1,100 / 2,500 W 5" / 8" @ 750 / 2,200 W 5" / 7"/ 9" @ 900 / 1,... capability to serve SAFeTY - 2-level digital control panel indicates when elements are still hot CeT304FS PerFOrmANCe - Touch control panel with blue light illumination offers 17 power settings -
... Wall Left Front Element Right Front Element Left Rear Element Right Rear Element Center Element Electrical Supply Required Circuit Breaker Conduit Shipping Weight (lbs.) CEM304FS CET304FS 4 31" 21 1/4" 28 3/4" - 28 7/8" 3 15/16" 1/4" 19 7/8" - 20" 2 1/4" 2 3/4" 6" @ 1,200W 7" @ 1,800W 5" / 7" @ 700 / 1,700 W 6" / 9" @ 1,100 / 2,500 W 5" / 8" @ 750 / 2,200 W 5" / 7"/ 9" @ 900 / 1,... capability to serve SAFeTY - 2-level digital control panel indicates when elements are still hot CeT304FS PerFOrmANCe - Touch control panel with blue light illumination offers 17 power settings -
Design Guide - Electric Cooktops
Page 6
..., CeT304FS 30-INCH ELECTRIC COOKTOP AND CUTOUT DIMENSIONS COUNTERTOP REQUIREMENTS 43/4" (121mm) TOE KICK Note: Dimensions based on standard countertop height (36" with all Masterpiece Electric Cooktops. COOKTOPS - This prevents the surfaces from both side walls and the back wall. Seal the surfaces of the oven. 1.800.735.4328 | THERMADOR.COM 125 Thermador...
..., CeT304FS 30-INCH ELECTRIC COOKTOP AND CUTOUT DIMENSIONS COUNTERTOP REQUIREMENTS 43/4" (121mm) TOE KICK Note: Dimensions based on standard countertop height (36" with all Masterpiece Electric Cooktops. COOKTOPS - This prevents the surfaces from both side walls and the back wall. Seal the surfaces of the oven. 1.800.735.4328 | THERMADOR.COM 125 Thermador...
Installation Instructions
Page 5
.... The stability of the countertop must be necessary. This prevents the surfaces from both sidewalls and the rear wall. Preparation Countertop requirements Note 30" Model: CES304FS CET304FS CEM304FS ř WARNING:ĄTo reduce the risk of ignition of surrounding combustible materials, install at least 2" (51mm) from swelling as they can affect the...
.... The stability of the countertop must be necessary. This prevents the surfaces from both sidewalls and the rear wall. Preparation Countertop requirements Note 30" Model: CES304FS CET304FS CEM304FS ř WARNING:ĄTo reduce the risk of ignition of surrounding combustible materials, install at least 2" (51mm) from swelling as they can affect the...
Installation Instructions
Page 10
It should be conform to the junction box. ř WARNING:ĄTo reduce the risk of the cooktop connection. Model CEM304FS CET304FS CES304FS CEM365FS CET366FS CES366FS CES365FS 240 V AC, 60 Hz system: circuit breaker 40 Amp 40 Amp 40 Amp 40 Amp 50 Amp 50 Amp 50 Amp ...
It should be conform to the junction box. ř WARNING:ĄTo reduce the risk of the cooktop connection. Model CEM304FS CET304FS CES304FS CEM365FS CET366FS CES366FS CES365FS 240 V AC, 60 Hz system: circuit breaker 40 Amp 40 Amp 40 Amp 40 Amp 50 Amp 50 Amp 50 Amp ...
User Manual
Page 33
... Within the United States or Canada, and has at all times remained within the country of purchase. How Long the Warranty Lasts Thermador warrants that the Product was purchased: D For your appliance available. Our central Customer Service Center (see below) will also be...effectuate warranty coverage, it Applies to The limited warranty provided by BSH Home Appliances Thermador in this Statement of Limited Product Warranty applies only to the Thermador CEM304FS, CEM365FS, CET304FS, CET366FS, CES304FS, CES365FS, CES366FS ("Product") sold to hearing from defects in the unlikely event ...
... Within the United States or Canada, and has at all times remained within the country of purchase. How Long the Warranty Lasts Thermador warrants that the Product was purchased: D For your appliance available. Our central Customer Service Center (see below) will also be...effectuate warranty coverage, it Applies to The limited warranty provided by BSH Home Appliances Thermador in this Statement of Limited Product Warranty applies only to the Thermador CEM304FS, CEM365FS, CET304FS, CET366FS, CES304FS, CES365FS, CES366FS ("Product") sold to hearing from defects in the unlikely event ...