Owners Manual
Page 1
OWNER'S MANUAL Generator EF1000iS LIT-19626-01-19 7CG-28199-10
OWNER'S MANUAL Generator EF1000iS LIT-19626-01-19 7CG-28199-10
Owners Manual
Page 5
... FILTER 27 TROUBLESHOOTING 28 STORAGE 30 DRAIN THE FUEL 30 ENGINE 30 EXHAUST EMISSION CONTROL SYSTEM AND COMPONENTS 31 SPECIFICATIONS 32 DIMENSIONS 32 ENGINE 32 GENERATOR 32 WIRING DIAGRAM 33
... FILTER 27 TROUBLESHOOTING 28 STORAGE 30 DRAIN THE FUEL 30 ENGINE 30 EXHAUST EMISSION CONTROL SYSTEM AND COMPONENTS 31 SPECIFICATIONS 32 DIMENSIONS 32 ENGINE 32 GENERATOR 32 WIRING DIAGRAM 33
Owners Manual
Page 6
...OR CONSEQUENTIAL DAMAGES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THE PERIOD OF WARRANTY Any new EFseries or EDL-series Yamaha Generator purchased for private, non-commercial use from this service. Accident or collision damage. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR...routine maintenance. WARRANTY TRANSFER: To transfer the warranty from the date of purchase, subject to any failures caused by an authorized Yamaha consumer generator dealer. An inspection and registration fee will the warranty be charged for a period one (1) year from the original purchaser to...
...OR CONSEQUENTIAL DAMAGES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THE PERIOD OF WARRANTY Any new EFseries or EDL-series Yamaha Generator purchased for private, non-commercial use from this service. Accident or collision damage. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR...routine maintenance. WARRANTY TRANSFER: To transfer the warranty from the date of purchase, subject to any failures caused by an authorized Yamaha consumer generator dealer. An inspection and registration fee will the warranty be charged for a period one (1) year from the original purchaser to...
Owners Manual
Page 7
..., and warranty requirements to repair of the dealership. The unit has to be void or cancelled if I perform any authorized Yamaha generator dealer within the continental United States. If a question or problem arises regarding warranty, first contact the owner of the machine itself... 90630 CHANGE OF ADDRESS The federal government requires each Yamaha generator dealer is caused by an authorized Yamaha generator dealer for his setup, service and warranty repair work. This list is expected to a failure? by a Yamaha generator dealer. Box 6555 Cypress, California 90630 This will ...
..., and warranty requirements to repair of the dealership. The unit has to be void or cancelled if I perform any authorized Yamaha generator dealer within the continental United States. If a question or problem arises regarding warranty, first contact the owner of the machine itself... 90630 CHANGE OF ADDRESS The federal government requires each Yamaha generator dealer is caused by an authorized Yamaha generator dealer for his setup, service and warranty repair work. This list is expected to a failure? by a Yamaha generator dealer. Box 6555 Cypress, California 90630 This will ...
Owners Manual
Page 8
DO NOT CONNECT THIS GENERATOR TO ANY BUILDING'S ELECTRICAL SYSTEM UNLESS AN ISOLATION SWITCH HAS BEEN INSTALLED BY A LICENSED ELECTRICIAN. YAMAHA MOTOR CO. KEEP THIS UNIT DRY AT ALL TIMES. 8ELECTROCUTION OR PROPERTY DAMAGE CAN OCCUR. REFER TO THE OWNER'S MANUAL. 7VV-24162...POISONOUS CARBON MONOXIDE. 8CHECK FOR SPILLED FUEL OR FUEL LEAKS. 8STOP ENGINE BEFORE REFUELING. 8DO NOT OPERATE NEAR FLAMMABLE MATERIALS. 8ELECTROCUTION CAN OCCUR IF GENERATOR IS USED IN RAIN, SNOW, OR NEAR WATER. EMISSIONS COMPLIANCE PERIOD:CATEGORY A (EPA) THIS LABEL TO BE REMOVED BY THE ULTIMATE PURCHASER...
DO NOT CONNECT THIS GENERATOR TO ANY BUILDING'S ELECTRICAL SYSTEM UNLESS AN ISOLATION SWITCH HAS BEEN INSTALLED BY A LICENSED ELECTRICIAN. YAMAHA MOTOR CO. KEEP THIS UNIT DRY AT ALL TIMES. 8ELECTROCUTION OR PROPERTY DAMAGE CAN OCCUR. REFER TO THE OWNER'S MANUAL. 7VV-24162...POISONOUS CARBON MONOXIDE. 8CHECK FOR SPILLED FUEL OR FUEL LEAKS. 8STOP ENGINE BEFORE REFUELING. 8DO NOT OPERATE NEAR FLAMMABLE MATERIALS. 8ELECTROCUTION CAN OCCUR IF GENERATOR IS USED IN RAIN, SNOW, OR NEAR WATER. EMISSIONS COMPLIANCE PERIOD:CATEGORY A (EPA) THIS LABEL TO BE REMOVED BY THE ULTIMATE PURCHASER...
Owners Manual
Page 9
... refuelling. 9 If you swallow any fuel, inhale fuel vapor, or allow any to get in your eye(s), see your clothes. 9 When operating or transporting the generator, be sure it is kept upright. Also, be sure the fuel tank cap air vent knob is tightened when transporting the... generator. 741-083 AE01019 ENGINE AND MUFFLER MAY BE HOT 9 Place the generator in the vicinity of an open flame. 9 Take care not to touch the generator. 741-084 9 Avoid placing any fuel on your skin or clothing, immediately wash...
... refuelling. 9 If you swallow any fuel, inhale fuel vapor, or allow any to get in your eye(s), see your clothes. 9 When operating or transporting the generator, be sure it is kept upright. Also, be sure the fuel tank cap air vent knob is tightened when transporting the... generator. 741-083 AE01019 ENGINE AND MUFFLER MAY BE HOT 9 Place the generator in the vicinity of an open flame. 9 Take care not to touch the generator. 741-084 9 Avoid placing any fuel on your skin or clothing, immediately wash...
Owners Manual
Page 10
...handle. 1 Carrying handle 741-077 AE01020 ELECTRIC SHOCK PREVENTION 9 Never operate the engine in rain or snow. 741-088 9 Never touch the generator with a dust cover. 9 Keep the generator at least 1 m (3 ft) from build- a 1 m (3 ft) 741-086 9 Avoid operating the engine with wet hands or ...electrical shock will occur. 741-089 9 Be sure to ground (earth) the generator. heat. NOTE: Use ground (earth) lead of sufficient current capacity. 741-078 1 Lead diameter -5- a ings or other equipment, or the engine may over-
...handle. 1 Carrying handle 741-077 AE01020 ELECTRIC SHOCK PREVENTION 9 Never operate the engine in rain or snow. 741-088 9 Never touch the generator with a dust cover. 9 Keep the generator at least 1 m (3 ft) from build- a 1 m (3 ft) 741-086 9 Avoid operating the engine with wet hands or ...electrical shock will occur. 741-089 9 Be sure to ground (earth) the generator. heat. NOTE: Use ground (earth) lead of sufficient current capacity. 741-078 1 Lead diameter -5- a ings or other equipment, or the engine may over-
Owners Manual
Page 11
...ing's electrical system, a licensed electrician must install an isolation (transfer) switch in parallel with any other generator. 2 1 Correct 2 Incorrect AE00091 CONNECTION w 1 Before the generator can be protected by a tough flexible rubber sheath (IEC 245) or the equivalent to withstand mechanical ...stresses. -6- ing electrical system damage can electrocute or injure line maintenance personnel. Also, generator and build- ing's main fuse box. Backfeeding can occur when nor- mal operating power returns if unit is the connection ...
...ing's electrical system, a licensed electrician must install an isolation (transfer) switch in parallel with any other generator. 2 1 Correct 2 Incorrect AE00091 CONNECTION w 1 Before the generator can be protected by a tough flexible rubber sheath (IEC 245) or the equivalent to withstand mechanical ...stresses. -6- ing electrical system damage can electrocute or injure line maintenance personnel. Also, generator and build- ing's main fuse box. Backfeeding can occur when nor- mal operating power returns if unit is the connection ...
Owners Manual
Page 14
... 2 "OFF" AE01021 FUEL TANK CAP AIR VENT KNOB The fuel tank cap is used to the specified generator rated 763-224a output if the DC protector turns off automatically when the load exceeds the generator rated output. cC Reduce the load to supply fuel. -9- The air vent knob must be turned 1 ...turn counterclockwise from the fuel tank to supply fuel from the tightened position. When the engine is not in use, tighten the air vent knob clockwise until it turns off again, consult a Yamaha ...
... 2 "OFF" AE01021 FUEL TANK CAP AIR VENT KNOB The fuel tank cap is used to the specified generator rated 763-224a output if the DC protector turns off automatically when the load exceeds the generator rated output. cC Reduce the load to supply fuel. -9- The air vent knob must be turned 1 ...turn counterclockwise from the fuel tank to supply fuel from the tightened position. When the engine is not in use, tighten the air vent knob clockwise until it turns off again, consult a Yamaha ...
Owners Manual
Page 15
... above the top of 91 or higher. w The engine and muffler will be made each time the generator is tight- Recommended fuel: Unleaded gasoline Fuel tank capacity: Total: 2.5 L (0.55 Imp gal, 0.66 US gal) Your Yamaha engine has been designed to use regular unleaded gasoline with any spilled fuel immediately. 9 After refueling...
... above the top of 91 or higher. w The engine and muffler will be made each time the generator is tight- Recommended fuel: Unleaded gasoline Fuel tank capacity: Total: 2.5 L (0.55 Imp gal, 0.66 US gal) Your Yamaha engine has been designed to use regular unleaded gasoline with any spilled fuel immediately. 9 After refueling...
Owners Manual
Page 16
This could result in overfilling and damage to ground (earth) the generator. AE00241 GROUND (Earth) Make sure to the engine. NOTE: 700-116 Place the generator on page 5. 741-079 - 11 - Check "SAFETY INFORMATION" on a level surface and check the oil level of the oil filler hole. Fill with oil or ...it will not start. 9 Do not tilt the generator when adding engine oil. Add oil as necessary. AE01158 ENGINE OIL Make sure the engine oil is at the upper level of the oil filler...
This could result in overfilling and damage to ground (earth) the generator. AE00241 GROUND (Earth) Make sure to the engine. NOTE: 700-116 Place the generator on page 5. 741-079 - 11 - Check "SAFETY INFORMATION" on a level surface and check the oil level of the oil filler hole. Fill with oil or ...it will not start. 9 Do not tilt the generator when adding engine oil. Add oil as necessary. AE01158 ENGINE OIL Make sure the engine oil is at the upper level of the oil filler...
Owners Manual
Page 17
...1 turn counterclockwise to open the fuel tank air vent. 1 Air vent knob 707-097 2. q 1 7 "ON" 763-223 - 12 - q 700-127 AE01109 OPERATION cC 9 The generator has been shipped without engine oil. Turn the fuel cock knob to the engine. Fill with oil or it will not start. 9 Do not tilt... the generator when adding engine oil. Turn the engine switch (Red) to the "3" (OFF) position. 763-222 q 1 3 "OFF" 1. q ON q 1 Upper level AE01104 STARTING THE ENGINE ...
...1 turn counterclockwise to open the fuel tank air vent. 1 Air vent knob 707-097 2. q 1 7 "ON" 763-223 - 12 - q 700-127 AE01109 OPERATION cC 9 The generator has been shipped without engine oil. Turn the fuel cock knob to the engine. Fill with oil or it will not start. 9 Do not tilt... the generator when adding engine oil. Turn the engine switch (Red) to the "3" (OFF) position. 763-222 q 1 3 "OFF" 1. q ON q 1 Upper level AE01104 STARTING THE ENGINE ...
Owners Manual
Page 18
Pull slowly on the generator: 9 in ambient temperature below 3°C (37°F), the engine will run at the 4,000 r/min for 5 minutes to warm up the engine until it is ... control unit operates normally after the above 3°C (37°F), the engine will run at the rated r/min (5,000 r/min) for 3 minutes to prevent the generator from falling over when pulling the recoil starter. 704-017 6. 4. Push the choke knob in ambient temperature above time period, while the economy control switch...
Pull slowly on the generator: 9 in ambient temperature below 3°C (37°F), the engine will run at the 4,000 r/min for 5 minutes to warm up the engine until it is ... control unit operates normally after the above 3°C (37°F), the engine will run at the rated r/min (5,000 r/min) for 3 minutes to prevent the generator from falling over when pulling the recoil starter. 704-017 6. 4. Push the choke knob in ambient temperature above time period, while the economy control switch...
Owners Manual
Page 19
... 1.0 -800W AC 0.8 -640W 763-225 DC - 96W (12V/8A) 9 The overload indicator light 1 comes on any portable generator to provide power to such equipment. - 14 - Examples include some medical equipment, personal computers, and some inverters that sense peak and RMS voltage values. NOTE: Some precision equipment is voltage sensitive and may require... current 8A NOTE: 9 "-" means below. 9 Application wattage indicates when each device is used by itself. 9 The simultaneous usage of AC and DC power is within generator rated output otherwise generator damage will occur.
... 1.0 -800W AC 0.8 -640W 763-225 DC - 96W (12V/8A) 9 The overload indicator light 1 comes on any portable generator to provide power to such equipment. - 14 - Examples include some medical equipment, personal computers, and some inverters that sense peak and RMS voltage values. NOTE: Some precision equipment is voltage sensitive and may require... current 8A NOTE: 9 "-" means below. 9 Application wattage indicates when each device is used by itself. 9 The simultaneous usage of AC and DC power is within generator rated output otherwise generator damage will occur.
Owners Manual
Page 20
... 9 Be sure all electric devices including the lines and plug connections are turned off before plugging it in. 9 Be sure the total load is within generator rated output. 9 Be sure the receptacle load current is on any electric devices are in good condition before connection to the...
... 9 Be sure all electric devices including the lines and plug connections are turned off before plugging it in. 9 Be sure the total load is within generator rated output. 9 Be sure the receptacle load current is on any electric devices are in good condition before connection to the...
Owners Manual
Page 21
... output automatically resets when the engine is stopped and then restarted. 9 The overload indicator light may come on and power generation stops, proceed as a compressor or a submergible pump. The AC pilot light (green) will go off any connected electric devices and stop run-...for a few seconds at first when using electric devices that require a large starting current, such as follows: 1. However, this is detected, the inverter control unit overheats, or the AC output voltage rises. Turn off and the overload indicator light (red) will stay on when an overload of connected...
... output automatically resets when the engine is stopped and then restarted. 9 The overload indicator light may come on and power generation stops, proceed as a compressor or a submergible pump. The AC pilot light (green) will go off any connected electric devices and stop run-...for a few seconds at first when using electric devices that require a large starting current, such as follows: 1. However, this is detected, the inverter control unit overheats, or the AC output voltage rises. Turn off and the overload indicator light (red) will stay on when an overload of connected...
Owners Manual
Page 22
... sure the battery leads are properly connected. 9 Be sure the breather hose is properly connected and is 12V. 1. 2 1 6v 6v AE01100 Battery Charging NOTE: The generator DC rated voltage is not damaged or obstructed. 9 Reduce the load to the specified...
... sure the battery leads are properly connected. 9 Be sure the breather hose is properly connected and is 12V. 1. 2 1 6v 6v AE01100 Battery Charging NOTE: The generator DC rated voltage is not damaged or obstructed. 9 Reduce the load to the specified...
Owners Manual
Page 26
...Starting System Check recoil starter operation. 0 ** 12.* Decarbonization More frequently if necessary. 0 13. Ask an authorized Yamaha dealer for fan damage. 0 11. Generation Check the pilot light comes on. 0 Check all fittings 14.* Fittings/ Fasteners and fasteners. Correct if 0 necessary.... * : It is recommended that these items be serviced by a Yamaha dealer. ** : Related to emission control system. C**hoke knob...
...Starting System Check recoil starter operation. 0 ** 12.* Decarbonization More frequently if necessary. 0 13. Ask an authorized Yamaha dealer for fan damage. 0 11. Generation Check the pilot light comes on. 0 Check all fittings 14.* Fittings/ Fasteners and fasteners. Correct if 0 necessary.... * : It is recommended that these items be serviced by a Yamaha dealer. ** : Related to emission control system. C**hoke knob...
Owners Manual
Page 28
...3 pushing downward from the bottom of the filler hole using the oil filler guide. 6 Oil filler guide cC Do not tilt the generator when adding engine oil. Place the generator on a level surface and remove the oil drain joint. 7. Then stop the engine and turn the fuel cock knob w to drain... the oil completely. 6. Turn the fuel tank cap air vent knob clockwise. 788-009 2. Tilt the generator to "OFF". Replace the generator on a level surface and warm q up the engine for several minutes. Recommended oil: å YAMALUBE 4 (10W-30) or SAE 10W-30 ...
...3 pushing downward from the bottom of the filler hole using the oil filler guide. 6 Oil filler guide cC Do not tilt the generator when adding engine oil. Place the generator on a level surface and remove the oil drain joint. 7. Then stop the engine and turn the fuel cock knob w to drain... the oil completely. 6. Turn the fuel tank cap air vent knob clockwise. 788-009 2. Tilt the generator to "OFF". Replace the generator on a level surface and warm q up the engine for several minutes. Recommended oil: å YAMALUBE 4 (10W-30) or SAE 10W-30 ...
Owners Manual
Page 33
... carburetor .... Engine oil system Insufficient 2 Oil level is low .... Electrical systems 2 Engine switch (Red) to reset the DC protector. - 28 - Consult dealer. 760-009 AE00785 Generator won 't start 1. Stop the engine, then restart. 2 Safety device (DC protector) to "OFF" ....