One Of The Light Does Not Work, We Have Replaced The Bulb

The person who posted this question about this Dacor product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by BusterDoogen on March 23rd, 2015 11:18 AM
This answer was accepted by the poster of the original question.
BusterDoogen

Member since:
October 30th, 2011

Points: 28,565,407
1,100
points
The suction cup, part number 62408, supplied with the IVS, is designed to assist in the removal and replacement of the halogen light bulbs, should they burn out.

To remove a bulb, simply press the suction cup onto the face of the bulb and unscrew in a counter-clockwise direction (as you are facing the bulb). To install the new bulb, start the new bulb in the socket in a clockwisedirection by turning a few times by hand, then attach the suction cup to the face of the bulb and complete the installation. Keep the suction cup in a safe place for future maintenance.

For replacement lamps, contact your Dacor parts distributor and order part number 62351.

I hope this is helpful to you!

Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful. Please feel free to submit further info for your question, if a solution was not provided. I appreciate the opportunity to serve you!

Related Dacor IVSR2 Manual Pages

Planning Guides - Page 1

...) 8" (20,3 cm) round exhausts with the accompanying installation instructions. IVS1 IVSR1 IVS2 IVSR2 Dedicated Circuit Required 120 Vac, 60 Hz., 15 Amp. Min. Specifications subject to change...hood structure to provide the required ventilation and heat resistant, easy to clean surfaces. 2" (5.1 cm) 13" (33.0 cm) 21" (53.3 cm) 8" (20.3 cm) ATD10 dimensions - For use with IVS2 and IVSR2...
Installation Instructions - Page 1

Installation Instructions Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Part No. 65278 Rev. H
Installation Instructions - Page 2

... Precautions 2 Product Specifications 3 General Specifications 3 Product Dimensions 3 Installation Requirements 4 Electrical Requirements 4 Planning the Duct Work 4 Installation Instructions 6 Installing the IVS 6 Installing the Duct Work 6 Electrical Connection 6 Verifying Proper Operation 7 Installation Checklist 7 Wiring Diagrams 8 Before You Begin... and Canada) Monday...
Installation Instructions - Page 3

... and lock the service disconnecting means to prevent power from cooktop burners, ovens and range hoods. WARNING Hazards or unsafe practices that COULD result in minor personal injury or property damage... OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must always be done by the National Fire Protection Association (NFPA), and...
Installation Instructions - Page 4

... and maintain performance. • If the cooktop and range hood are in use an appropriate window treatment. Plastic bags... A qualified service technician should not install, repair or replace any part of this appliance unless specifically recommended in the.... • Never leave the range or cooktop unattended when a burner (or element) is not working properly. Use only the cleaners specified...
Installation Instructions - Page 5

...hood canopy. Requirements* grounded , dedicated circuit IVS1: 0.2 kW (2 Amp.) Total Connected Load* IVS2: 0.4 kW (3 Amp.) IVSR1/IVSR2... IVSR1 and IVSR2: Dependant on ...System (IVS) is designed for installation inside custom hood canopies. Min. Product Dimensions All dimensional tolerances are... Dimensions IVS2, IVSR2 Overall Dimensions 6 1/2" 6 1/2" (16.5 cm) (16.5 cm...
Installation Instructions - Page 6

... securely. • Use only duct work materials (including screws and duct tape) must be purchased separately by state, municipal and local codes. • Range hoods may be obtained from: National Fire ...remote blower rated maximum 7 Amps. (IVS1 and IVS2) or maximum 8 Amps. (IVSR1 and IVSR2). To avoid drawing lethal gases into attics, crawl spaces or garages. • To prevent combustion ...
Installation Instructions - Page 7

...work. • On dual exhaust models, the two 8 inch exhausts may Calculating the Maximum Duct Run Length also be subtracted from the maximum duct run to compensate for Models IVSR1 and IVSR2: Models IVSR1 and IVSR2...See the table below from the hood exhaust as possible, and as ...replace it with floor joists or wall studs. Keep turns as possible. To determine the length the duct work...
Installation Instructions - Page 8

...the cutout while routing the wiring harness to the hoods electrical system. Connect them to the blower installation instructions. 2. Models IVSR1 and IVSR2 only: Install the remote or in-line blower (...) power supply wire. REMP wiring terminal inside hood GREEN Not used Gnd GREEN WHITE N1 WHITE BLACK L1 BLACK Installing the Duct Work WARNING During duct installation, make sure that keep...
Installation Instructions - Page 9

...being supplied to the IVS. • Check the electrical connections to one of the provided light bulbs. • Insert it into place and remove the section cup. • Repeat for the... Repeat the above test. • If the installation still does not work completely installed? See page 6. ‰‰ Is the range hood wired and grounded according to have all applicable electric codes? Do not...
Installation Instructions - Page 10

Wiring Diagrams GROUND NEUTRAL LINE WH BLK LAMP DIMMER BLK BLK HALOGEN LIGHTS (2) WH BLK FAN MOTOR M WH FAN SWITCH IVS1, IVSR1 GROUND NEUTRAL LINE WH BLK LAMP DIMMER WH BLK BLK BLK HALOGEN LIGHTS (3) WH BLK FAN MOTORS M M IVS2, IVSR2 FAN SWITCH 8
Use & Care Manuals - Page 1

NOTES: Contains helpful hints and tips. E Use and Care Manual Custom Hood Integrated Ventilation Systems For use with models: IVS1, IVSR1, IVS2 and IVSR2 SAFETY IS EVERYONE'S RESPONSIBILITY. THE OPERATION WILL BE FURTHER ENHANCED IF PROPER CARE AND JUDGEMENT ARE EXERCISED IN THE USE AND MAINTENANCE OF THIS APPLIANCE. ...
Use & Care Manuals - Page 3

... hazard. 6. Do not repair or replace any part of the surface element. This...INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: a) ...in the area where the cooktop and hood are near a window, use a ... Controls 2 Energy Saving Tips 2 Care and Cleaning 2 Changing the Light Bulb 2 BEFORE YOU CALL FOR SERVICE 3 Troubleshooting 3 Product Maintenance 3 ...
Use & Care Manuals - Page 4

...lights and the blower. Select cookware of the bulb and unscrew in a clockwise direction by turning a few minutes before using the cooking appliance. 4. Turning the knobs clockwise will be replaced... down. Proper cleaning is in an automatic dishwasher. Eliminate air currents in the hood's vicinity by placing them again. CAUTION: If commercially available stainless steel cleaners are...
Use & Care Manuals - Page 5

...and time consuming. The owner must provide proof of purchase, due to replace the defective part. THEREFORE, NO OTHER EXPRESS WARRANTIES ARE MADE, AND ... Customer Service Team and share your encounter with us. A loose or burned out light. Lights do not turn on how long an implied warranty lasts, or do not allow ...works. NO WARRANTIES, EXPRESS OR IMPLIED, ARE MADE TO ANY BUYER FOR RESALE....
Use & Care Manuals - Page 8

... have in your name or any of expressing our gratitude! Kitchen Dealer  C. Builder Supplier  D. Other 3. For what purpose was the product purchased?  A. Replacement only  B. What is your warranty online. Under $75,000  B. $75,000 - $100,000  C. $100,000 - $150,000  D. $150,000 - $200,000...

Similar Questions

Light Bulbs
Where Can I Buy The Lightbulbs That Go In A Dacor Range Hood Eh/ehr3612
(Posted by ltiessen4 8 years ago)
Dacor Hood Model Dhw301 - Light Function?
The info states 2 lights - is there a low and high function for the lights?
(Posted by Anonymous-78178 11 years ago)
Ask a New Question
Use the box below to post a new question about this Dacor product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dacor Manuals

Find free Dacor IVSR2 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dacor Reviews

View thousands of Dacor user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dacor customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dacor customer service rankings, employee comments and much more from our sister site.