Control Functions Erratic
Unit comes up normally.
Push button for down: unit goes down then comes back up.
Push button while unit is down and it will stay down.
But blower stays on.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dacor PRV30 Manual Pages
Planning Guides - Page 1
...planning guide for the particular appliance for external blower
NOTES:
1. This appliance must not exceed the maximum specified countertop height of unit
Product data label 28" 3 prong
grounded power... notice. www.Dacor.com Phone: (800) 793-0093
8.1
Document # PG08-001
ERV30, ERV36, ERV48, PRV30, PRV36, PRV46
30", 36", 46", 48" Wide, Slim Raised Vent
Revised 03/29/10 Page 1/3
...
Planning Guides - Page 2
....
Two staggered 45° angles are used with model and configuration. ERV/PRV30 ERV/PRV36
PRV46 ERV48
Approved Dacor Blowers*
Remote blowers: REMP3 or REMP16
In-line blowers: ILHSF8 or ILHSF10
For example, for a raised vent system using 3 1/4"... allowable length of the duct work that can be subtracted from the hood exhaust as possible, with as much space between each 90° elbow...
Planning Guides - Page 3
...
Front of bottom knock- www.Dacor.com Phone: (800) 793-0093
8.3
Document # PG08-001
ERV30, ERV36, ERV48, PRV30, PRV36, PRV46
30", 36", 46", 48" Wide, Slim Raised Vent
All tolerances: ±1/16" (±1.6 mm) ...On 30" and 36" wide models, the vertical center line of unit
Blower wiring access hole in
side
Blower wiring access hole in bottom
Wiring/conduit connections for rEmote/in-line...
Installation Instructions - Page 1
See the installation instructions for the particular appliance model being
installed to determine suitability. Installation Instructions
Downdraft Raised Vent
Models: ERV30, ERV36, ERV48 PRV30, PRV36, PRV46
Part No. 65335 Rev. L
Use these downdraft raised vents only with approved Dacor ® appliances.
Installation Instructions - Page 2
...In the interest of ANSI Z 21.1 standard for household gas cooking appliances, ANSI/UL 858 household electrical ranges, CAN/CSA-C22.2 NO. 64 Standard for Household
Electric Cooking and Liquid Heating Appliances, and UL 507...The model and serial number are printed on the product data label on the front of the unit. PRV30 = 30-inch wide raised vent, PRV style top cap PRV36 = 36-inch wide raised ...
Installation Instructions - Page 3
... about problems and conditions that COULD result in accordance with all possible problems and conditions that could explode, such as aerosol cans, away from the range or cooktop. See Customer Service Information. d) Ducted fans must be vented to prevent back drafting.
Safety Symbols and Labels
DANGER
Immediate hazards that WILL result...
Installation Instructions - Page 4
...suffocation.
• For proper operation, this unit unless specifically recommended in accordance with the controls.
• Never allow the filters or... of the customer to have it replaced with a range, cooktop or the raised vent. Do not allow children... remote or in use only. This appliance is in -line blower. Grounding type
electrical outlet
Three prong grounding plug
2 Do not...
Installation Instructions - Page 5
...
30 1/4" (76.8 cm)
30" (76.2 cm)
37 t1o/4"*
(94.6 cm)
B
6" (15.2 cm)
Motor cover Front of unit
Adjustable anchor legs
Product data label 28" 3-prong
grounded power cord
See page 6 for exhaust locations and dimensions.
* Maximum height of raised vent... down
9/16" (1.4 cm)
Tolerances: ±1/16" (±1.6 mm) unless otherwise stated
Model Number
ERV30 PRV30
ERV36 PRV36
PRV46
ERV48
A -
Installation Instructions - Page 6
...are 7/8" access holes in bottom
Electrical Access Hole Locations
4 Front of unit
Blower wiring access hole in
side
Blower wiring access hole in the bottom and side of 8 Amps. Plug it... coming out of the raised vent itself and a single Dacor approved remote or in -line blower installation instructions. grounded, dedicated, single phase circuit is required.
• Refer to the range/cooktop...
Installation Instructions - Page 7
... raised vent to round transition
Floor
Wall cap on outside wall
Duct work
Duct work
ILHSF series in-line blower
Example of cabinet front
Notches required for some raised vent installations, see range installation instructions
Notches for self-rimming style installations, see cooktop installation instructions
See the cooktop installation instructions for exact...
Installation Instructions - Page 10
...-out on the back of vent resting on the chassis other than those shown.
If the unit will exhaust air from the range or cooktop. PN 36862) • 2 wood screws, #14 x 2 ½ (PN...decrease performance. Install the raised vent before installing the range or cooktop. NOTE: The raised vent installs in the back of unit
ADT2 bottom installation
Attach sealing foam
ADT2 Transition Installation...
Installation Instructions - Page 11
... the duct weight as necessary to the blower installation instructions.
2.
Install the duct work between raised vent and remote blower
Range
Raised vent configured for rear
exhaust
Floor
...10" round transition and 45° adjustable elbow
REMP series remote blower
Floor
6. Install the remote or in-line blower according to ensure sealed joints. Anchor leg
Front of vent resting...
Installation Instructions - Page 12
... to complete electrical connections properly may result in an electric shock hazard or a damaged or non-functional system. Match wire colors to the duct work.
2.
Remove the cover from the raised vent to the blower parallel to terminals as shown
To power wiring/conduit. Make sure all wiring away from the electrical...
Installation Instructions - Page 14
...function after installation:
• Make sure that power is being supplied to the unit.
• Make sure that power is being supplied to the blower from the hot surfaces of the range or cooktop.
□□ Is the unit... plug into place? Turn the variable speed control switch in -line blower power cable connected (to the raised vent and to the blower itself)?
□□ Are the vent ...
Installation Instructions - Page 15
Wiring Diagram
DOWN LIMIT SWITCH
COM NO NC
UP LIMIT SWITCH
COM
NC NO RED
SNORKEL SWITCH
COM NO NC
RED BLUE
BLK YEL
WHT BLUE
REMOTE POT
ORNG BLK
YEL WHT
RELAY
N COM NO
L
SPEED CONTROL RED
ORNG
BLK
CHASSIS GROUND STUD
WHT
L2 N2 L1 N1 GND GND
BLOWER POWER OUTPUT INPUT
GROUND
13
Use & Care Manuals - Page 1
Use and Care Manual Downdraft Raised Vent
Models: ERV30, ERV36, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV46
Style varies. Model ERV36 shown.
Ta b l e o f C o n t e n t s
Important Safety Instructions 1 Operating Your Raised Vent 3 Care and Cleaning 4 Before You Call for Service 5 Warranty and Service 6 Notes 7
Part No. 103107 Rev. E
Use & Care Manuals - Page 4
... under any part of interest to children above or around the range when it properly.
• Never leave a cooktop or range unattended during use .
Important Safety Instructions
General Safety Precautions
To reduce the risk of a Range Top Grease Fire:
◊ Never leave surface units unattended at high heat or when flambéing food...
Use & Care Manuals - Page 5
...blower and lowers the vent intake. Remove the obstruction, reconnect the power plug and press the Up/Down switch to remain on a gas cooktop is in the vent vicinity by turning the variable speed control. Operating Your Raised Vent
Operation
important
The direction of travel of the flame is a normal...flame on the unit's surfaces. Pressing the switch shuts off the blower, disconnect the ...
Use & Care Manuals - Page 6
...surrounding surfaces are cool before re-installing them.
Rinse off the range and vent and make sure all surrounding areas, external and ...up " position to clean the filters.
2. Avoid introduction of the unit.
4.
Raise the vent to the "up .
1. Care and... surfaces, use abrasive cleaners or scrubbers on both ends and push down.
3. Gently wipe the top cap surfaces with mild ...
Use & Care Manuals - Page 8
...for service. THEREFORE, NO OTHER EXPRESS WARRANTIES ARE MADE, AND OUTSIDE THE FIFTY STATES OF THE UNITED STATES, THE DISTRICT OF COLUMBIA, AND CANADA, ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO... DISTRICT OF COLUMBIA, AND CANADA:
LIMITED FIRST YEAR WARRANTY
If your DACOR product fails to function within one year of the original date of Dacor service agents for Service section on our ...
Similar Questions
How Do I Replace The Trim Ring Around The Lightbulb On A Dacor Ivsr1 Range Hood?
(Posted by glenrobertson 3 years ago)
Light Bulbs
Where Can I Buy The Lightbulbs That Go In A Dacor Range Hood Eh/ehr3612
Where Can I Buy The Lightbulbs That Go In A Dacor Range Hood Eh/ehr3612
(Posted by ltiessen4 8 years ago)
Dacor Rv36 Does Not Rise, Controls Ineffective
My Dacor RV36 downdraft exhaust fan has operated well for quite a few years, but recently it stopped...
My Dacor RV36 downdraft exhaust fan has operated well for quite a few years, but recently it stopped...
(Posted by bertrandkan 10 years ago)
Dacor Hood Model Dhw301 - Light Function?
The info states 2 lights - is there a low and high function for the lights?
The info states 2 lights - is there a low and high function for the lights?
(Posted by Anonymous-78178 11 years ago)
Erratic Rv30 Raised Vent
Vent unit goes up and down on it's own and doesn't stop!
Vent unit goes up and down on it's own and doesn't stop!
(Posted by edeyc13 11 years ago)