my pac120el is constantly dripping water.out of the drain. I have to empty a bucket multiple times a day.
Current Answers
Answer #1: Posted by INIMITABLE on July 15th, 2020 8:38 AM
UNPLUG THE UNIT FIRST. All left and right reference below is as view from the BACK of the unit (NOT from the front). Open the right side panel (right as view from the back), by removing six screws (remove screw covers first) and pull down on the panel to remove. Towards the UPPER-back of the unit, there is a cold air evaporator(?)(bunch of tubes and fins) you can only see the edge of it after removing the right panel. Below it is a white plastic drip tray with a hole at the end allowing water to pass down to the lower warm air radiator(?) (another bunch of tubes and fins) to evaporate. If this hole is obstructed, water will over flow and leak. I cleaned out the hole with a vacuum attached to a drinking straw, you might have a better way. After cleaning, I poured a little water through to make sure it drains. There is a lower drip tray at the bottom of the unit which catches the water and you can drain it out the bottom drain hole by unplugging the rubber stopper at the back bottom of the unit. The lower drip tray has a float switch (you can only see it by removing the back panel, which you don't have to do for this procedure) which turns off the unit when the lower tray is full. So, theoretically, even if the evaporation is not working properly, as long as the upper drain hole is not obstructed, there should not be any leakage, because the water will drain into the lower drip tray and turn the unit off when it is full. The upper drain hole obstruction might be causing most of the leakage problem. Also make sure the unit is level left to right. If the left side (left as viewed from the back) is lower than the right side (as view from the back) the water in the upper drip tray might not flow to the drain hole properly and might overflow. You should also vacuum and clean the upper plastis filter screen (pull it out from the top back of the unit). Before closing the right side panel, you might want to vacuum and clean the lower warm air radiator, be careful not to damage the fins. Again before you start any of this, UNPLUG THE UNIT FIRST. This might be easier than packing and sending the over 90 pounds unit to an out of town service center. I understand some service centers might charge $100 for a simple cleaning. Consult a trained technician if you don't have the skill to do this. Do this procedure at your own risk because I am not sure if it might void you warranty. Again UNPLUG THE UNIT FIRST before you start.
I hope this is helpful? PLEASE "ACCEPT" and mark it "HELPFUL" to complement my little effort. Hope to bring you more detailed answers
-INIMITABLE
Related DeLonghi PAC A120E Manual Pages
Similar Questions
My Portable Air Condition Is Blowing Hot Air
(Posted by Anonymous-171442 1 year ago)
Do You Empty Water From It Or Just Clean The Filter?
(Posted by balentinelori3623 2 years ago)
Delonghi Pac A120 El:i Just Want To Remove The Cover To Vacuum All The Dust.
Please provide instructions on how to remove the cover. Where are all the screws located as I only f...
Please provide instructions on how to remove the cover. Where are all the screws located as I only f...
(Posted by peterskatherine 3 years ago)
Delonghi Portable Air Conditioner Pac-130hpe Operators Manual
My Units Air Cond. Works When I Plug It In But I Cant Control The Mode Or Speed Of Blower And Only W...
My Units Air Cond. Works When I Plug It In But I Cant Control The Mode Or Speed Of Blower And Only W...
(Posted by captainjohn8 10 years ago)