How To Clear Dell 6248

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerConnect 6248 Manual Pages

User's Guide - Page 19

...; 1U form factor, rack-mountable chassis design. • Support for PoE capability. The Dell PowerConnect 6224F switch supports 24 1000Base-FX SFP ports and 4 "combo" ports for RJ-45 or SFP interfaces. The topics covered in this product. The Dell PowerConnect 6248 supports 48 1000Base-T copper ports and 4 "combo" ports for power-over-Ethernet (PoE) capability...
User's Guide - Page 59

... or a stacking module. The left slot (Bay 1) can be used to manage an entire stack. PowerConnect 6224, 6248, and 6224F Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots for ...mounted on the rear. Rear Panel Each PowerConnect 6200 series switch provides an RS-232 maintenance port, on the rear of the switch. RS-232 management port DC power AC power Figure 4-7.
User's Guide - Page 62

... short stacking cables from stacking port one each of the switches in rear "Bay 1" of each on the next switch. 3. The PowerConnect 6248 has four fans. See "System LEDs" on page 67 for information. Stacking You can stack up to 12 PowerConnect 6224 and/or 6248 switches, supporting up to stacking port two on the top and...
Getting Started Guide - Page 21

Front Panels and LEDs This appendix describes the front panels and LEDs of the Dell PowerConnect PC6224, PC6248, PC6224P, PC6248P, and PC6224F systems. Front Panels The front panels of the PowerConnect 6200 series systems are shown in the figures below. PC 6224P Getting Started Guide 19 PC 6224 Figure 1-2. PC 6248 Figure 1-3. Figure 1-1.
Getting Started Guide - Page 266

...port counters show stack-port diag show switch‬‬ ‫‪show supported switchtype‬‬ LED‬‬ LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224‬ו‪.PC6224F -‬‬ PowerConnect 6200 ‫‪PC 6224‬‬ 1-1‬‬ ‫‪PC 6248‬‬ 2-1‬‬ ‫‪...
Release Notes - Page 1

... notices to change without the written permission of Intel Corporation; DellPowerConnect™ 6224/6224F/6224P/6248/6248P PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Date: May 2010 System Firmware Version 3.2.0.6 Information in this text: Dell, the DELL logo and PowerConnect are trademarks of Dell Inc; All rights reserved. Intel and Pentium are registered trademarks...
Release Notes - Page 3

...follow the procedure set forth in the Dell PowerConnect 6200 Series Release 3.2 Upgrade Procedure included in your switch becoming inoperable. Failure to adhere to this product. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Introduction This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6. Firmware Specifications Firmware...
Release Notes - Page 4

... 6224 PowerConnect 6248 PowerConnect 6224F PowerConnect 6224P PowerConnect 6248P 2 System Firmware Version 3.2.0.6 Firmware Downgrade Downgrading from 3.2.0.6 to version 4.2. Denotes an ad hoc release of the product software. Denotes a scheduled maintenance release of the product software. NOTE: OMNM 4.1 will not discover the switches running any version of 3.x.y.z firmware therefore...
Release Notes - Page 5

... an alternative to support this option is an extension of the switch will be used for protocol-based VLANs. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Added Functionality in this Release ¾ Non-Stop...session. When the management unit fails, only the management switch needs to be unique. ¾ HTTP Download Allow users to its module ID. System Firmware Version ...
Release Notes - Page 7

PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ MLD Snooping (RFC2710) In IPv4, Layer 2 switches can use IGMP Snooping to limit the flooding of the ports in -the-middle attacks, where an unfriendly station intercepts traffic ... extended to include support for Voice VLAN Allow the user to share information between neighboring devices (routers, bridges, access servers, and switches).
Release Notes - Page 9

... has been added to enable clearing of the ARP table of entries learned from the management port. ¾ OSPFv2 Point-to-Point Links OSPF can occur in a network. ¾ OSPF v2/v3 Passive Interfaces Allows passive interfaces for a particular set of IP prefixes. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Ping...
Release Notes - Page 11

...or specific OSPF neighbors • Flush and re-originate all self-originated external LSAs • Clear OSPF statistics ¾ Support of IPv6 routes in a 6 to 4 domain that can not... level of a virtual router for the transmission of various types of ICMP messages. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Configured Tunnels MTU To comply with RFC 4213, Basic Transition...
Release Notes - Page 15

...for configuring a static IPv4 multicast route has changed . PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Trap Configuration In previous ...versions of the software, configuration of places. Previously it was increased from 128 to 128. If your previous configuration had flow control disabled, you upgrade a switch...
Release Notes - Page 19

...Unable to the default. Firmware missing no version of issues resolved in prompt to remove switch x priority x. Re-enabled objects to be rebooted for syslog description is a list ... in connected_unit/connected_stby state. Process SET_ASSET_TAG event while in SNMP group. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Issues Resolved The following is different between Web and...
Release Notes - Page 21

...of VLANs to be the same as all 0s) in the Switching > VLAN > ProtocolGroup web page. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Description Cannot enter Daylight Saving Time from Web... Page 19 OpenManage Web UI shows invalid MAC address (all zeros. Made modifications to the Switching > VLAN > ProtocolGroup web page in CLI help . When priority is set through Web interface...
Release Notes - Page 23

...neighbor for a restarting router. Use this command to revert the grace period to clear the statistics of the check pointing process. Use the "no" form of ...Default: Non-stop forwarding. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes CLI Reference Manual Updates Non-Stop Forwarding Title nsf no nsf show nsf show checkpoint statistics clear checkpoint statistics vlan routing ...
Release Notes - Page 25

... Firmware Version 3.2.0.6 Page 23 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes RADIUS Accounting Servers Title radius-server host acct Description The switches do not support creating accounting server...configure a port on a CX-4 or stacking plug-in Interface Config Mode to the DellPowerConnect™ 6200 Series Systems CLI Reference Guide for 90 seconds. The user will not ...
Release Notes - Page 27

...control plane may be applied when the port leaves the LAG. User Impact When the switch reboots and attempts to a physical port while it is not successful on neighbors. In ... config. User cannot enter Privileged EXEC mode without using TACACS as TACACS. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Known Issues Summary Non-configuration file getting read an invalid ...
Release Notes - Page 31

PowerConnect 6224/6224F/6224P/6248/6248P Release Notes LACP Description LAGs Supported VLAN Description vlan association mac ... Impact This behavior is for the management interface and ip default route is a known limitation of the PowerConnect 6200 series switches. DiffServ Description Failed to attach diffserv policy to become active with mark cos and assign queue attributes. ...
Configuration Guide - Page 54

...Dell tested the switch software with Nessus. Each type of features that help a network administrator protect networks against the exploitation of a number of vulnerabilities which can be monitored for and blocked. Enables TCP fragment checking. 54 Switching... of the switch - Enables TCP flag checking. Denial of Service Attack Protection This section describes the PowerConnect 6200 Series ...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerConnect 6248 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.