Dell PowerConnect 6248 Support Question
Find answers below for this question about Dell PowerConnect 6248.Need a Dell PowerConnect 6248 manual? We have 5 online manuals for this item!
Question posted by funaji on January 26th, 2014
What Is Command To Show Collisions Dell Powerconnect 6248
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell PowerConnect 6248 Manual Pages
User's Guide - Page 19
... data-communication requirements for RJ-45 or SFP interfaces. 1
Introduction
This section describes the switch user-configurable features. The Dell PowerConnect 6248 supports 48 1000Base-T copper ports and 4 "combo" ports for RJ-45 or SFP interfaces. The topics covered in this product. The Dell™ PowerConnect™ 6200 series are provided with hot swappable stack members.
User's Guide - Page 72
... IP address, corresponding management access granted, and a workstation connected to access the switch through a Telnet connection. The switch can access the switch without a user account if you are for use the Easy Setup Wizard.
2. However, to the switch before using CLI commands.
72
Configuring Dell PowerConnect
NOTE: If you 're directly connected to complete the required tasks...
User's Guide - Page 74
... that are delivered with Telnet, SSH, and so forth
74
Configuring Dell PowerConnect
Terminal Connection Configuration Your switch requires the following terminal connection parameters for configuration: • no parity...the unit • Assigned IP address for the switch for changing the default baud rate using CLI commands:
console#configure
console(config)#line console
console(config...
User's Guide - Page 88
... where a number of possible subcommands or to fully complete the command.
In this case, the unit number identifies the physical device ...Switching Port Default Settings
When configuring/receiving IP addresses through DHCP and BOOTP, the configuration received from these servers includes the IP address, and may include subnet mask and default gateway.
88
Configuring Dell PowerConnect...
User's Guide - Page 89
...PowerConnect 6200 Series switches:
• SwitchA> -
SwitchA#configure
SwitchA(config)#exit
SwitchA#
The following table describes the switch port default settings. Enter this by typing configure at the privileged EXEC mode.
• SwitchA(config-if)# - this prompt is in a privileged EXEC mode (not in the command... (Enabled) On Off
Configuring Dell PowerConnect
89 To go to enter ...
User's Guide - Page 90
... Protocol Current......... Enter the following steps:
1. DHCP Management VLAN ID 1 Routing Interfaces: Netdir Multi
90
Configuring Dell PowerConnect NOTE: You do not need to delete the switch configuration to retrieve the IP address. console#show ip interface command at the system prompt as shown in the following is an example for changing the port...
User's Guide - Page 92
... • When changing a switch mode to enable, enter secret123 at the password
prompt. • When changing a switch's mode to enable, enter pass1234. Configuring an Initial HTTP Password To configure an initial HTTP password, enter the following commands:
console(config)#ip http authentication local console(config)#username admin password user1234 level 15
92
Configuring Dell PowerConnect
User's Guide - Page 93
..., enter the following commands once when configuring to use an HTTPS session over a console, a Telnet, or an SSH session.
Configuring Dell PowerConnect
93
Enter the following commands:
console(config)#ip https authentication local NOTE: You should generate a new crypto certificate each time you upgrade (install a new version of) the control software application on the switch.
User's Guide - Page 94
The TFTP server must run the boot system command to be downloaded is currently running on the
switch.
94
Configuring Dell PowerConnect
Ensure that the file to activate the newly downloaded image. To download an image through a TFTP server. NOTE: You must be sent to start? (y/n) y
console#...
User's Guide - Page 95
... other copy of system image (image2, as given in the example). Enter the command copy tftp://{tftp address}/{file name} image to copy a new system image to start? (y/n) y
Configuring Dell PowerConnect
95 The following is saved in the area allocated for the duration of the transfer Are you sure you want to the switch.
User's Guide - Page 96
...Activating image image2 .. 5.
Configuration Not Saved!
Enter y.
console>show version to continue? (y/n) 7. Are you sure you want to reboot the switch.
96
Configuring Dell PowerConnect After this command, enter the command show version
Image Descriptions
image1 : default image
image2 :
Images currently available on Flash
unit image1 image2 current-active next-active...
User's Guide - Page 97
... message displays:
Boot Menu Version: 3.2.0.1
Select an option. If no selection in the following command:
console#update bootcode
Update bootcode and reset (Y/N)? 2. Start operational code.
2 - Select (1, 2):
Configuring Dell PowerConnect
97 Enter y to reboot the switch.
For each switch, the bootcode is completed. Start Boot Menu. Update Bootcode Use the update bootcode...
User's Guide - Page 105
.... ASCII terminal application (for the purpose of switch when powered up - The sample screen uses the HyperTerminal. Configuring Dell PowerConnect
105
A browser application • One Null ...following components installed:
- Network adapter card - This section also describes accessing a switch for the first time with the following components are required for example, Microsoft®...
User's Guide - Page 111
... was deleted
console#reload
Management switch has unsaved changes.
Enter the enable command at the privileged mode prompt...command at the console to enter the Privileged EXEC screen mode as shown below: console#
01-Jan-2000 01:43:03 %LINK-I-Up: Vlan 1
01-Jan-2000 01:43:03 %LINK-I-Up: 1/xg1
01-Jan-2000 01:43:34 %STP-I-PORTSTATUS: Port 1/xg1: STP status Forwarding
Configuring Dell PowerConnect...
User's Guide - Page 112
....168.20.1 200 6.
time=0 ms
64 bytes from 50.1.1.2: icmp_seq=4.
Enter the config command at the console to Privileged Exec mode: console(config)#ip address dhcp
console(config)#exit ... authentication local
112
Configuring Dell PowerConnect Use the following command to set the IP address to DHCP and return to enter the Configuration mode as one of the switch IP interfaces. Wait 30...
User's Guide - Page 114
... securely through the standard Web browser, the SSL (Secure Socket Layer) security protocol is used. The switch Dell OpenManage™ Switch Administrator displays.
114
Configuring Dell PowerConnect Connect to create a security key, use the commands
ip https server and crypto certificate 1 generate: console#configure
console(config)#crypto certificate 1 generate
Generating RSA private key...
Release Notes - Page 3
... version of firmware be thoroughly reviewed prior to installing or upgrading of this procedure may result in the zip file to the firmware management system. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Introduction
This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6.
Release Notes - Page 4
...to version 4.2.
NOTE: OMNM 4.1 will not discover the switches running any version of 3.x.y.z firmware therefore users should save their...of the product software. Hardware Supported
PowerConnect 6224 PowerConnect 6248 PowerConnect 6224F PowerConnect 6224P PowerConnect 6248P
2
System Firmware Version 3.2.0.6 ...Dell™ PowerConnect™ 6200 Series Systems CLI Reference Guide and the...
Release Notes - Page 25
...
Title banner motd no banner motd
banner motd acknowledge no banner motd' to the Dell™ PowerConnect™ 6200 Series Systems CLI Reference Guide for 90 seconds. Use 'no configuration should be preserved and no ' form of the command to the login prompt. Default: Disabled by default. System Firmware Version 3.2.0.6
Page 23
The...
Configuration Guide - Page 9
...create and use the Dell™PowerConnect™ 6200 Series switch in a typical network. It describes the advantages of specific functions the PowerConnect 6200 Series switch provides and includes ... TACACS+ servers.
• "IPv6" on page 135 describes configuring and using the command line interface (CLI).
About this Document
This configuration guide provides examples of -service (...
Similar Questions
What Does The Dhcp Helper Command Do In Dell 6224 Switches
(Posted by sdtrave 9 years ago)
How To Document Dell Powerconnect 6248 Configuration
(Posted by wertscu 10 years ago)
How To Setup User Login For Enable Command On Powerconnect?
(Posted by cnifrien 10 years ago)