Get support for Dell PowerEdge R310

Dell PowerEdge R310 Support Question

Dell PowerEdge R310 Support Question

Find answers below for this question about Dell PowerEdge R310.
Need a Dell PowerEdge R310 manual? We have 9 online manuals for this item!
Question posted by mohdsandy on March 18th, 2014

How To Clear Disk Fault Dell R310

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by JCatDell on March 18th, 2014 9:49 AM
This answer was accepted by the poster of the original question.
JCatDell

Member since:
March 11th, 2014

Points: 136,220
1,100
points
Hi,

It depends on which RAID controller is installed. The first step would be to test the drive and see if it actually bad. Rebooting the system and pressing F10 during post will bring you to the lifecycle controller which includes diagnostics to test the drives. If the drive fails, it should be replaced and that will clear the error. If the test passes you may be able to rebuild the drive into the RAID array if it is in an array.


Josh Craig

Dell | Social Outreach Services - Enterprise
Get Support on Twitter @DellCaresPro

Related Dell PowerEdge R310 Manual Pages

Glossary - Page 5

... - Milliampere-hour(s). A system used for implementing shared storage on a network. However, when referring to hard-drive capacity, the term is monitored and managed using Dell OpenManage™ Server Administrator. A small circuit board containing DRAM chips that is often rounded to serve specific storage needs. A portable flash memory storage device integrated with a USB...
Glossary - Page 7

... or hardware, that enables remote networkattached storage devices to appear to a server to its contents even after you turn off your system. A registered DDR3... event log. Redundant array of providing data redundancy. A method of independent disks. RAID on the system used to connect a modem to the system....you call Dell for program instructions and data. Serial Advanced Technology Attachment...
Glossary - Page 58

... 와 SVGA W - 와트 (Watt WH Watt-Hour WMI - Windows Management Instrumentation 은 CIM ZIF Zero Insertion Force provider CIM management station managed system) 은 Dell OpenManage™ Server Administrator x x y x z 58
Getting Started Guide - Page 3

DellPowerEdgeR310 Systems Getting Started With Your System Regulatory Model: E07S Series Regulatory Type: E07S002
Getting Started Guide - Page 4

...to hardware or loss of data if instructions are trademarks of Dell Inc.; All rights reserved. Microsoft, Windows, and Windows Server are trademarks of Citrix Systems, Inc. in the United States..., Inc. Other trademarks and trade names may be used in this text: Dell, the DELL logo, and PowerEdge are either the entities claiming the marks and names or their products. A00 ...
Getting Started Guide - Page 9

...AP (Version 4.8) (x86) • Red Hat Enterprise Linux Server (Version 5.3) (x86_64) • Red Hat Enterprise Linux Server (Version 5.3) (x86) • SUSE® Linux Enterprise Server 11 (x86_64) • SUSE® Linux Enterprise Server 10 (x86_64) with SP3 • Citrix® XenServer&#...10 Update 10 NOTE: For the latest information on supported operating systems, see support.dell.com.
Hardware Owner's Manual - Page 1

DellPowerEdgeR310 Systems Hardware Owner's Manual Regulatory Model: E07S Series Regulatory Type: E07S002
Hardware Owner's Manual - Page 2

... the written permission of Dell Inc.; Information in this text: Dell, the DELL logo, and PowerEdge are trademarks of Dell Inc. Reproduction of these materials in any proprietary interest in trademarks and trade names other countries. is subject to either trademarks or registered trademarks of your computer. Dell Inc. A00 Microsoft, Windows, Windows Server, and MS-DOS...
Hardware Owner's Manual - Page 11

... diagnostics. About Your System Accessing System Features During Startup The following keystrokes provide access to the system. For more information, see the Unified Server Configurator documentation at support.dell.com/manuals. Enters System Services, which allows access to the System Event Log (SEL) and configuration of remote access to system features during...
Hardware Owner's Manual - Page 32

...(continued) Code Text Causes Corrective Actions E1810 Hard drive ## The specified hard drive fault. If the problem persists, replace cable. If the problem persists, see "Getting ..."Getting Help" on page 153. 32 About Your System Table 1-2. Review has experienced a fault. & clear SEL. See "Troubleshooting a Hard Drive" on page 169. upgrade has failed. E1A14 SAS...
Hardware Owner's Manual - Page 37

... requires more power Check PSU and than what the power system supply can often specify a very precise fault condition that is automatically removed when that sensor returns to the system, reduce the hardware configuration or install...is not installed in this table, see the Glossary at support.dell.com/manuals. requires more power than what the power supply can boot if throttled.
Hardware Owner's Manual - Page 38

Any of these actions will reboot. Rebooting. The system will remove fault messages, and return the status indicators and LCD colors to notify you receive... appears or the operating system's documentation for an explanation of a possible problem with the system. • Clear the SEL-You can perform this task remotely, but fails again, resulting in the table, check the documentation...
Hardware Owner's Manual - Page 45

... an Optical Drive" on page 156, or "Troubleshooting a Hard Drive" on the disk, cables, or optical drive cables or the requested sector is no device connected Information ...appropriate drive(s) installed in your system. System Messages (continued) Message Causes Corrective Actions Read fault. There is are properly connected. device, or USB medium. See "Troubleshooting a USB ...
Hardware Owner's Manual - Page 48

...latest version on page 169. If the problem persists, see "Getting Help" on support.dell.com. Ensure that the memory modules are installed in the system the latest software to .... System halted after F10 Restart the system and keystroke because System update the Unified Server Services image is not supported by Install a supported processor. Unexpected interrupt in protected ...
Hardware Owner's Manual - Page 51

... device. Ensure that the USB, SAS backplane, or SATA cables are properly connected. Write fault on page 158. NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary at support.dell.com/manuals. See "Troubleshooting a USB Device" on page 146, "Troubleshooting an Internal USB Key...
Hardware Owner's Manual - Page 71

...unauthorized changes. Embedded System Management The Unified Server Configurator is not locked through the Password Status option, you want to clear the existing setup password. The following options.... 2 Highlight Setup Password, press to validate the memory, I/O devices, processor, physical disks, and other peripherals Using the System Setup Program and UEFI Boot Manager 71 The following ...
Hardware Owner's Manual - Page 72

... optional iDRAC6 Express card is installed, Unified Server Configurator provides the following features: • Enables fault logging and SNMP alerting • Provides access...BMC enables configuring, monitoring, and recovery of system functions including power on the Dell Support website at support.dell.com/manuals. The BMC provides the following additional features: • Downloading and...
Hardware Owner's Manual - Page 73

...iDRAC Configuration Utility provides the following features: • Enables fault logging and SNMP alerting • Provides access to system event... and set parameters for the iDRAC6 and for the managed server. iDRAC Configuration Utility The iDRAC Configuration Utility is a pre.... • View System Event Log (SEL) messages or clear messages from the log. If your operating system begins to ...
Hardware Owner's Manual - Page 119

Installing System Components 119 See "Opening the System" on the system back panel. Read and follow the safety instructions that is not authorized by Dell is clear of the back panel. 8 Lift the card out of the retention standoffs. See "Closing the System" on , including any attached peripherals, and disconnect the system ...
Hardware Owner's Manual - Page 153

... the product. NOTE: Invalid memory configurations can cause your product documentation, or as authorized in their sockets. If diagnostics indicates a fault, follow the safety instructions that is not authorized by Dell is not covered by the online or telephone service and support team. Troubleshooting System Memory CAUTION: Many repairs may only be...

Similar Questions

Dell Server Poweredge R710 Error Message Error 1
hi Good Day,we are having issue with our dell R710 with error message error 1 but we look up in OMSA...
(Posted by jillustrisimo32 4 years ago)
Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge R310 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.