Get support for Dell PowerEdge R610

Dell PowerEdge R610 Support Question

Dell PowerEdge R610 Support Question

Find answers below for this question about Dell PowerEdge R610.
Need a Dell PowerEdge R610 manual? We have 13 online manuals for this item!
Question posted by carch on November 27th, 2013

Poweredge R610 Does Not Power On After Second Processor Installed

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerEdge R610 Manual Pages

Glossary - Page 6

... revised to create an image. PERC - processor - The primary computational chip inside the system that communicates with managed objects and accesses data and event notifications from a variety of arithmetic and logic functions. A provider is an implementation-specific integer or pointer that provides electrical power to servers and storage systems in rows and columns...
Glossary - Page 56

... NAS NIC Network Interface Controller NMI Nonmaskable Interrupt NMI ns Nanosecond NVRAM Nonvolatile Random-Access Memory NVRAM OID Object Identifier PCI Peripheral Component Interconnect PDU Power Distribution Unit PERC - PowerEdge RAID POST Power-On Self-Test POST RAM PXE Preboot eXecution Environment LAN R-DIMM DDR3 Registered DDR3 Memory Module 56
Information Update - Intel Xeon 5600 Series Processors - Page 1

... download the BIOS and iDRAC firmware for the Intel Xeon 5600 series processor at support.dell.com. NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to support Intel Xeon 5600 series processor (less than 130 W). R710 - T610 - M710 NOTE: The PowerEdge R410, T410, and R510 systems do not support 130 W Intel Xeon...
Information Update - Intel Xeon 5600 Series Processors - Page 2

...BIOS setup options allow the user to PowerEdge R410, R510, R610, R710, R910, T410, T610, ...and T710 systems only. NOTE: Applies to control frequency and voltage configuration within allowable limits. Low Voltage Memory Modules (DDR3L DIMMs) Intel Xeon 5600 series processors support DDR3L DIMMs enabling a lower operating voltage (1.35 V) that ensures memory power...
Information Update - Intel Xeon 5600 Series Processors - Page 10

... PowerEdge M610 和 M710 Intel Xeon X5677 130 W ECC 启用 Dell BIOS 智能 Turbo 模式 Dell BIOS 智能 Turbo turbo turbo Processor Settings...23383;段值 智能 Turbo CPU Power and OS DBPM Performance Management (CPU 已启用 CPU Power and System DBPM 已禁用 Performance...
Information Update - Processor Installation - Page 3

... seconds for 3 seconds to fully drain the system of stored power prior to the touch for a system-specific illustration. See "Opening the System" in the Hardware Owner's Manual. Allow the heat sink and processor to remove the processor. Processor Installation 3 WARNING: The heat sink and processor are authorized to maintain proper thermal conditions. 5 Release one of...
Information Update - Processor Installation - Page 4

Figure 1-1. See Figure 1-2. 4 Processor Installation Installing and Removing the Heat Sink 2 1 1 heat sink 2 release lever (2) NOTE: Your heat sink may appear differently than the one shown above. Rotate the lever 90 degrees upward until the processor is held in its socket under the tab. CAUTION: The processor is released from under strong pressure. Be aware that...
Information Update - Processor Installation - Page 5

... damage the system board. 11 Carefully, lift the processor out of the pins on the ZIF socket when removing the processor. See "Installing a Processor". Processor Installation 5 Do not touch the bottom of the processor. Touch only the side edges of the processor. If you are permanently removing the processor, you must install a processor blank and a heat-sink blank in an antistatic...
Information Update - Processor Installation - Page 6

... hold it straight down into the socket. 6 Align the notches in place. 6 Processor Installation Do not touch the bottom of the processor. See Figure 1-3 and Figure 1-4. CAUTION: Do not use force to float on the top of the processor. When the processor is positioned correctly, it to remove the system cover and access any of...
Information Update - Processor Installation - Page 7

Keeping the Processor Parallel to the Socket Figure 1-4. Aligning the Processor with the Socket Keys 2 1 3 4 7 1 socket-release lever 3 processor shield 5 socket key (2) 7 pin 1 indicators (2) 5 6 2 processor 4 notch in processor (2) 6 ZIF socket Processor Installation 7 Figure 1-3.
Information Update - Processor Installation - Page 8

... not appear different than the original one; CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and contaminating the processor socket. 8 Processor Installation a Using a clean lint-free cloth, remove the thermal grease from the heat sink. See Figure 1-5. 10 Rotate the socket-release lever down until it...
Information Update - Processor Installation - Page 9

.... d Close the heat-sink release levers or replace the screws at the corners of the heat sink. Processor Installation 9 c Place the heat sink on the system. 15 Press to their electrical outlets, and turn on the processor. See "Entering the System Setup Program" in the Hardware Owner's Manual. 16 Run the system diagnostics...
Information Update - Processor Installation - Page 10

10 Processor Installation
Dell PowerEdge Deployment Guide - Page 6

... for the mass storage drivers. Depending on Dell Servers with ADS when two Intel™ Xeon™ processors are installing, the mass storage drivers may cause a problem. PowerEdge Deployment Guide Manual Installation of Microsoft Operating Systems This installation method involves booting to the operating system installation DVD to an error while booting the RAMDISK. This...
Hardware Owner's Manual - Page 53

... used in this table, see "Troubleshooting System Memory." System Messages (continued) Message Causes Corrective Actions Warning! A High Output power supply Install two High Output or and an Energy Smart power two Energy Smart power supply are installed in the system. The recommended memory configuration is not optimal. NOTE: For the full name of the same...
Hardware Owner's Manual - Page 89

... full-height, half-length cards. • The expansion-card slots are not hot-swappable. • PCI Express Generation 1 and Generation 2 expansion cards are installing a second power supply. CAUTION: Expansion cards can have a power consumption of greater than 15W (up to 25W maximum), not including the integrated storage controller. • Table 3-1 provides a guide for...
Hardware Owner's Manual - Page 105

... simple repairs as directed by your product documentation, or as authorized in a single-processor configuration, the fan will still be done by Dell is the same. 1 Turn... and support team. Removing and Replacing a Fan 1 2 3 1 fan 3 fan assembly 2 power cable Installing System Components 105 Read and follow the safety instructions that is not authorized by a certified service technician...
Hardware Owner's Manual - Page 146

... system diagnostics. Troubleshooting the System Battery 1 Re-enter the time and date through the System Setup program. CAUTION: Many repairs may only be installed for at least one power supply must be done by replacing the battery, see "Getting Help." If the problem is not covered by your product documentation, or as...
Hardware Owner's Manual - Page 171

... - A video mode that provides remote management capabilities, crashed system recovery, and power control functions for Dell PowerEdge systems. "iDRAC6" refers to 1,000,000,000 bytes. The ability to insert or install a device, typically a hard drive or an internal cooling fan, into the host...,741,824 bytes. A systems management hardware and software solution that can be sent to the processor.
Hardware Owner's Manual - Page 182

..., 115 removing, 114 phone numbers, 167 POST accessing system features, 11 power indicators, 12, 21 power supplies indicators, 21 removing, 87 replacing, 88 troubleshooting, 146 power supply blank, 89 processor installing, 125 removing, 122 troubleshooting, 157 R RAID battery installing, 114 removing, 114 remote access controller See iDRAC. P password setup, 74 system, 72 passwords disabling...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge R610 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.