Get support for Fluke 419D

Fluke 419D Support Question

Fluke 419D Support Question

Find answers below for this question about Fluke 419D.
Need a Fluke 419D manual? We have 1 online manual for this item!
Question posted by deanhanel on January 20th, 2014

Change The Measurement Tolerance

On the 419D, can you change the tolerance from 1/32" to 1/16"?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Fluke 419D Manual Pages

Fluke 414D, 419D, 424D Laser Distance - Manual - Page 1

All rights reserved. Specifications are trademarks of their respective companies. All product names are subject to change without notice. 414D/419D/424D Laser Distance Meter Users Manual June 2012 © 2012 Fluke Corporation.
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 3

... 4 Integrated Distance Meter 4 Laser Class 2 Products 4 Features ...5 Before You Start...6 Batteries ...6 Multifunctional Endpiece 7 Keypad ...8 Display...9 Button Functions ...10 On/Off ...10 Basics ...10 Units of Measurement 11 Timer (419D/424D)...12 Beeper (419D/424D 12 i
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 4

... Magnetic Declination 14 Clear ...16 Measurements with a Tripod 16 Reference Point ...16 Measurements ...17 Single Distance Measurement 17 Minimum/Maximum Tracking 17 Addition/Subtraction 18 Area ...18 Volume...19 Tilt (424D only)...20 Smart Horizontal Mode (424D only 20 Height Tracking (424D only 20 Leveling...21 Tilt Sensor Calibration 22 Stake Out Measurement (419D/424D 23 Corner Angle...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 7

... to a target, the area, and the volume measurements. The Meter includes: • Most advanced technology for distance measurements • More accurate measurement • Longer measurement distance - Use these Meters to quickly and accurately ... Distance Meter Introduction The Fluke 414D/419D/424D Laser Distance Meters (Meter or Product) are professional-grade laser distance meters.
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 8

... or battery compartment. W Important information. Go to prevent incorrect measurements. • Do not use the Product around explosive gas. ...or indirectly off reflective surfaces. Conforms to the user. Symbols Description  Battery status. 414D/419D/424D Users Manual Safety Information A Warning identifies hazardous conditions and procedures that can be compromised. ...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 11

... Distance Meter Features 414D • 419D • 424D 5 Model Feature Comparison 414D 419D 424D Feature Display Lines 2 3 4 Timer Memory[1] 20 20 Display/Keypad Illumination Add/Subtract • • • Keypad Lock Area • • • Tripod Measurement Volume • • • Compass Continuous Measurement • • Triangular Area...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 12

... the handstrap. 3. W Caution To prevent corrosion, remove the batteries before a long period of nonuse. 6 gwo01.eps It also describes the Meter keypad and display. 414D/419D/424D Users Manual Before You Start 2 This section has basic information about the batteries and measurement reference point. To install or replace the batteries: 1.
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 13

See Figure 4. • For measurements from an edge, fold out the endpiece (90 °) until it locks into ...Before You Start gwo03.eps gwo04.eps 7 Push the endpiece lightly to the right side to multiple measurement situations with the multifunctional endpiece, see Figure 3: • For measurements from a corner, fold out the endpiece (90 °) until it locks into place. Multifunctional...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 14

... function button on the keypad. 6 414D 1 419D 1 424D 1 3 4 2 3 4 8 7 8 9 13 5 11 6 6 10 5 6  Measure/Power On  Plus (+)/Minus (-)  Plus (+)/Scroll Up  Minus (-)/Scroll Down  Clear/Off  Reference/Change Units  Area/Volume/Indirect Measurement (Pythagoras)  Indirect Measurement (Pythagoras and Stake Out) 8 ...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 15

... Figure 7 shows the readout location on the display for each function. 7 414D 3 21 8 419D 14 31 28 19 4 9 4 10 5 5 11 12 12 7 6 13 7 6 14 20 424D 3 1 4 15 10 2 11 16 18 12 13 17 6 8 19 9 21 5 7  Battery Status  Units of Measurement  Info  Pythagoras  Area/Volume  Memory ...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 16

...  for 2 seconds = Continuous Laser On Push : • 1x = Laser On • 2x = Measure • 2 seconds = Tracking (min/max measurement) Function Buttons Push : • 1x = Pythagoras 1 • 2x = Pythagoras 2 • 3x = Pythagoras 3 • 4x = Stake Out (419D: 1 value / 424D: 2 values) 10 On/Off Push  to use the buttons and identifies...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 17

... = 2nd Results Laser Distance Meter Button Functions Units of Measurement 414D  419D/424D  0.000 m 0 00″ 1/16* 0 in 1/16 * Default 0.000 m 0.0000 m 0.00 m 0.00 ft 0′00″ 1/32* 0.000 in 0 in 1/32 * Default 11 Units of Measurement Push and hold  (414D) or  (419D/424D) for 2 seconds to toggle between the units for distance...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 18

... prevents Meter movement when you use a time-delay for 2 seconds to turn on the timer: 1. The seconds until measurement (for 2 seconds to lock the keypad. The display shows the status as or Backlight (419D/424D) Push   at the same time for example, 59, 58, 57...) show as or Keypad Lock...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 20

... the Meter with the correct compensation for your local Geomagnetic Institute. The display shows and the current setting. 414D/419D/424D Users Manual 8 Z 180° Y 180° X 180° gwo22.eps Magnetic Declination The difference...; to accept the new value. 14 Push  to change the value. 3. The geographic and magnetic poles are aligned so declination is 0 °. 2.
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 22

...16 Push :  • 1x = Measure from front  • 2x = Measure from tripod screw  • 3x = Measure from the end of the Meter. The display shows or . 419D...2 seconds = Turn off Meter Measurements with a Tripod Measurements with the 419D and 424D that use the endpiece and shows on , the Meter beeps as you change to change the reference point. When set ....
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 26

... when the line-of measure as the Meter turns on a tripod. To change the units, push and hold the Meter without a transverse tilt (±10 °). To measure: 1. The z (horizontal...Height Tracking starts automatically. 414D/419D/424D Users Manual Tilt (424D only) Note The inclinometer senses tilts at target. 3. Push . For tilt measurements, hold   at ...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 29

... the values. 3. An example of this application is recommended to beep at a distance of change for a stake out measurement. See page 16 for more information. 14 1 2 3 0.625 m 0.625 m a 0.625 m b b a = b 1 2 3 1.012 m 0.625 m a 0.625 m b b gwo11.eps Laser Distance Meter Measurements 419D (1 Value) To find stake out distances with 1 value:  1. Note For best results...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 30

... Note It the beeper feature is on the display. 8. 414D/419D/424D Users Manual 424D (2 Values) You can enter two different distances (a and b) into the Meter and use them to mark off measured lengths, for the values. 4. Push  4x. shows ... point. As the Meter moves near to the stake out point, the beep changes and the arrows do not show on , the Meter starts to increase the rate of...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 36

414D/419D/424D Users Manual Message codes Table 5 is a list of measurement range 260 Laser beam interrupted Correct the range. If the code ...up. 255 Received signal too low, measurement time too long 256 Received signal too high Change target surface (for example, white paper) 257 Too much background light Darken target surface. 258 Measurement outside of all message codes that the...
Fluke 414D, 419D, 424D Laser Distance - Manual - Page 37

...[5] Measurement tolerance to case[5] Range Compass accuracy 414D 419D 424D ± 2.0 mm (± 0.08 in)[3] ± 3.0 mm (± 0.12 in)[3] ± 1.0 mm (± 0.04 in)[3] ± 2.0 mm (± 0.08 in)[3] 50 m / 165 ft 80 m / 260 ft 100 m / 330 ft 40 m / 130 ft 80 m / 260 ft 35 m / 115 ft 60 m / 200 ft 1 mm / 1/16 in...

Similar Questions

No Power After Battery Change
I left my meter on volts and it sat for about 6 months when I went to use it the batteries were obvi...
(Posted by Ragius 8 months ago)
Changing The Date And Time On A Cnx I3000
How do you change the date and time on a CNX i3000 ?
(Posted by jturner35540 3 years ago)
Measuring Flow Volume
Is it possible to use one hose connected to the pitot tube to measure the flow volume ?
(Posted by romycamacho 9 years ago)
Measure Outdoor Air
With a Fluke 975 Air Meter, can you measure outdoor air directly or calculate outdoor air from tempe...
(Posted by mvalles 10 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 419D manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls