Get support for Haier AU182AEEAA

Haier AU182AEEAA Support Question

Haier AU182AEEAA Support Question

Find answers below for this question about Haier AU182AEEAA.
Need a Haier AU182AEEAA manual? We have 1 online manual for this item!
Question posted by bazileae on December 19th, 2011

I Have A Haier Au60naieaa With The Operation Light Flashing 6 Times Each Minute.

The person who posted this question about this Haier product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Haier AU182AEEAA Manual Pages

User Manual - Page 1

ROOM AIR CONDITIONER OUTDOOR UNIT INSTALLATION INSTRUCTIONS AU142AEEAA AU182AEEAA CONTENTS Name of Parts 1 Safety Cautions 2-3 Installation Procedure---------4-13 AU242AGEAA AU282AHEAA AU28NAHEAA AU36NAIEAA AU48NAIEAA AU52NAIEAA AU60NAIEAA No.0010577959 Before using the air conditioner,please read this manual properly for future use. Please keep this manual carefully.
User Manual - Page 3

.... Safety Cautions Carefully read the following important Safety Cautions. Below are listed three kinds of air-conditioner the base should be at hand so that they can ensure the correct operation of death or serious injuries. Incorrect operations may result in some cases may cause electrical shock or fire hazard. in injuries or machine...
User Manual - Page 4

...other-wise may cause shock. It easily cause electrical shock without circuit breaker. Don't operate the air-conditioner with inflammable gases because the inflammable gases near to the gas pipe, water pipe, lightning...and fire hazard. Safety Cautions WARNING! Installed electrical-leaking circuit breaker. Air-conditioner can't be sure to take measures to prevent suffocation accident even in ...
User Manual - Page 5

... not be kept from an opening edge. Place where obstacles do not exist near the air inlet and air outlet . Place surrounded at the same time, obtain a consent from other heat sources. Selection of the place of installation Select the place of installation satisfying the following conditions and, at four sides ...
User Manual - Page 6

... Fix the unit in a proper way according to the following . AU142AEEAA AU182AEEAA AU242AGEAA AU282AHEAA AU28NAHEAA (a) Concrete foundation (b) Foundation anchor Unit Unit Anchor bolt Concrete foundation To fix by bolts Concrete foundation Anchor bolt AU36NAIEAA AU48NAIEAA AU52NAIEAA AU60NAIEAA (a) Concrete foundation (b) Foundation anchor Unit Anchor bolt Unit Concrete foundation To...
User Manual - Page 8

Refrigerant piping (1) Outline piping AU142AEEAA AU182AEEAA AU242AGEAA AU282AHEAA AU28NAHEAA AU36NAIEAA AU48NAIEAA AU52NAIEAA AU60NAIEAA Flare connection Gas pipe 3-way stop valve Indoor unit Liquid pipe Flare connection Outdoor unit 3-way stop valve 7 Installation Procedure Installation of outdoor unit AU36NAIEAA AU48NAIEAA AU52NAIEAA AU60NAIEAA 948 Power wiring Terminal 380 1250 25 ...
User Manual - Page 9

... for gas leakage. (4) Piping connection Connecting method (indoor unit) Apply refrigerant oil at half union as large and flare nut. Model AU142AEEAA AU182AEEAA AU242AGEAA AU282AHEAA AU28NAHEAA AU36NAIEAA AU48NAIEAA AU52NAIEAA AU60NAIEAA One way piping length less than 20 m Vertical height difference (between indoor and outdoor) less than 10 m less than 30 m less than...
User Manual - Page 10

... closed (Liquid side) First step: 0.3MPa (3. 0kg/cm2g) pressurize over 3 minutes. TUBING BRING BRAZED LINE PRESSURE GAUGE SWEAT JOINT LARGE SLIP-ON CONNECTOR SERVICE HOUSE CYLINDER... After confirming the leaking point, welding it shall perform air tightness test. Installation Procedure Refrigerant piping 5. The air tightness test adopts nitrogen tank to give pressure according to...
User Manual - Page 11

... is : Refrigerant charging amount = (L-5) x M (g) For AU142AEEAA, AU182AEEAA, M=30 For AU242AGEAA, AU282AHEAA, AU28NAHEAA, AU36NAIEAA, AU48NAIEAA, AU52NAIEAA, AU60NAIEAA, M=50 Only in liquid condition. 10 Check the leaking point and... degree and large air discharging (over 2 hours vacuumizing, the vacuum degree is any leaking point and repair the them. The vacuumizing time depends on the ...
User Manual - Page 12

... 1 40 AU28NAHEAA 3 30 AU36NAIEAA AU48NAIEAA AU52NAIEAA 3 30 AU60NAIEAA 26 6.0 40 30 20 2.5 30 30 20 4.0 30 30 (2) Wiring connection Make wiring to supply power to the terminal block. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS. (1) Selection of size of the air conditioner should be no less 3 mm. Use copper conductor...
User Manual - Page 13

...opening for electric wiring on the side panel. 12 Installation Procedure For: AU142AEEAA, AU182AEEAA To Indoor Unit Electric wiring OUTDOOR UNIT 1 2 3 TERMINAL BLOCK Y/G FIG.1 ... SUPPLY: 1PH, 220-230V~, 50Hz OUTDOOR UNIT TERMINAL BLOCK FIG.2 For:AU28NAHEAA, AU36NAIEAA, AU48NAIEAA, AU52NAIEAA, AU60NAIEAA To Indoor Unit R S TN 1 2 3 Y/G OUTDOOR UNIT TERMINAL BLOCK POWER SUPPLY: 380-400V,...
User Manual - Page 14

... air and supply air for about 30 minutes, and check the following. Test run Run the unit continuously for indoor unit. 7. Suction pressure at check joint on for gas pipe. Discharge pressure at check joint of exterior annunciator Coil gas pipe temp. sensor abnormal Indoor coil temp. sensor abnormal Code on wired Flash times of operation...
User Manual - Page 15

Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266555, P.R.China Web Site: http://www.haier.com HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd.

Similar Questions

Haier Air Conditioner Model
Haier air conditioner model HSU-12CJ03 when turn on the AC after 1 min blower moter turn off and ora...
(Posted by husnainmd 6 years ago)
Portable Air Conditioner Keeps Shutting Off
my portable air conditioner keeps shutting down after running for about 10 min
(Posted by Buttercup2 6 years ago)
My Air Conditioner Go Off
when the air conditioner is funtion for only little time like 20 minute is going to signal the STOP ...
(Posted by haydeejose 7 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier AU182AEEAA manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.