Question posted by jajoshfrede on September 16th, 2014

Pcb Board Bad.

“-Pcb-” displayed and all 4 red/yellow LEDs are illuminated.

Current Answers

Answer #1: Posted by TommyKervz on September 17th, 2014 4:37 AM
TommyKervz

Member since:
January 10th, 2013

Points: 17,776,793
100
points
Download the AQ-RT-PRO Oct 08 & later below and read the instructions from page 17

http://www.helpowl.com/manuals/Hayward/AquaRite/152363


Hope that is helpful.
Kervz at www.satechhelp.co.za

Related Hayward Aqua Rite Manual Pages

AQ-RT-PRO Oct 08 & later - Page 4

... anAQL-CHEM2 (120V),AQL- 2 CHEM2-240 (240V) or other restrictions. for pool or spa sanitization. The Aqua Rite Pro can be used around a saline pool with the Aqua Rite Pro and must be tasted. OPERATION The Aqua Rite Pro is an automatic chlorine generation system for pools up to 40,000 gallons T-CELL-9 - Chlorine will continuously recycle virtually eliminating the...
AQ-RT-PRO Oct 08 & later - Page 5

Your authorized Aqua Rite Pro dealer or most pool stores can provide you are using an Aqua Rite Pro chlorine generator. Insert values of Pool and Spa Professionals (APSP). If Si equals .2 or more, scaling and staining may occur. -.2 0 .2 COR ROSIVE SCALING OK 2 Saturation index The saturation index (Si) relates to adjust ...
AQ-RT-PRO Oct 08 & later - Page 6

... Depth x 893 The ideal salt level is not lost due to your pool/spa is usually available in low chlorine production. Salt is between 2700-3400 ppm...Aqua Rite Pro to shutdown and may take longer for 24 hours with the suction coming from the main drain (use rock salt, salt with yellow...display may begin to partially drain the pool and refill with anti-caking additives, or iodized salt.
AQ-RT-PRO Oct 08 & later - Page 12

...Aqua Rite Pro and adjust various settings. Following the steps of water over 1000 gallons. Refer to next menu item Requires use of the optional AQL-CHEM Sensing Kit. Config. + to view/change BodyCohfloWriantaetrorType PEnooalbsled Display... Salt Cell Type T-CELL-15 Push to access Chlorinator option Move to previous/next menu item Toggle between Pool and Spa Move ...
AQ-RT-PRO Oct 08 & later - Page 14

...Aqua Rite Pro will beep every time a key is NOT reversible--be set longer to the factory default values. filter run time each day. For pools...menu item This function controls the backlight on the display. Display Light On for 60 sec Toggle between Always On... when the pool water temperature increases significantly, when there is higher than normal bather load or when your pool/spa and after...
AQ-RT-PRO Oct 08 & later - Page 16

... is designed to mount horizontally on a flat surface with Local and NEC codes. 120/240 VAC POWER AQUA RITEpro FROM FROM POOL SPA TO TO SPA POOL Preparing Pool/Spa Water Refer to the Aqua Rite Pro system. Do not mount Aqua Rite Pro inside the box), it is important not to block the four sides of non-copper based algaecide...
AQ-RT-PRO Oct 08 & later - Page 17

... and cell should be purchased separately. Refer to be plumbed into consideration the space necessary for chlorination of both the pool and spa during spa spillover operation, but prevent overchlorination of the cell. The Aqua Rite Pro is packaged with a flow switch and cell unions. The cell must be in the return line to the...
AQ-RT-PRO Oct 08 & later - Page 18

... the factory with an 8 AWG copper wire (6 AWG Canada) to the bottom of both the pool and spa during spillover but preventing overchlorination when operating the spa only. The Aqua Rite Pro must be connected to the LOAD SIDE of Aqua Rite Pro Enclosure Second bonding lug for Canadian models). Wiring Power must be properly grounded and...
AQ-RT-PRO Oct 08 & later - Page 22

... If the CSM indicates that there is detected on the printed circuit board. • Cell Missing -- If a pH level of 8.1 or...has been chlorinating for proper operation • pH High - The Aqua Rite Pro will stop generating chlorine under certain high salt conditions in ... are OK, the timeout may need to partially drain the pool and add fresh water. • Chlorinator Cell Sensor -- Check...
AQ-RT-PRO Oct 08 & later - Page 23

...HAYWARD/GOLDLINE CHLORINATOR CELL PURCHASED FROM HAYWARD/GOLDLINE. Hayward/Goldline also warrants its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and... freezing, external water, degradation of purchase is not transferable and applies only to a pool or spa, war or acts of one (1) year. NO WHOLESALER, AGENT, DEALER, CONTRACTOR OR...
AQR - Page 9

... a 15-60 second time delay period. OFF: The OFF position prevents the Aqua Rite from energizing the electrolytic cell. Indicator LED's POWER When illuminated, the Aqua Rite has input power. See description above. When flashing, the pool water is in the SUPER CHLORINATE position. NOTE: To service any other condition which needs a large amount of the super...
AQR - Page 11

... and visually inspect the cell every 3 months or after cleaning your pool/spa and after approximately 500 hours of the summer and down accordingly. The Pro Logic, Intellitouch or Eos can be controlled from the pool automation display/keypad. The "Remotely Controlled" LED on the Aqua Rite chlorinator will remind you inspect the cell (and clean, if...
AQR - Page 16

... that the colors marked on PCB 1 BLK / GND yellow black 2 GRN / -DT Intellitouch 3 YEL / +DT red 4 RED / +15 13 NOTE: There must be only 1 "primary" unit. Attach wires to proper screw terminals as shown below. GOLDLINE, PENTAIR or POLARIS AQUA RITE (240 VAC) AQUA RITE (120 VAC) SUBPANEL GND GND NEUTRAL GROUND PCB BONDING LOOP PCB BONDING LOOP Optional Goldline...
AQR - Page 17

...CHLORINATE. "No Flow" LED illuminated The Aqua Rite has sensed a no flow condition and has stopped generating chlorine. Common Problems and Solutions 1. The Aqua Rite is not pushed for helpful information on the circuit board above the cell connector. 2. Attach wires to the pool automation control display ("AL-0" which signifies "Aqua Rite") 7. Diagnostic Displays Sequential pushes of...
AQR - Page 18

.... - Aqua Rite® switch in pool water. - Desired Output % adjustment setting is scaled, follow the directions on page 8. Very warm pools increase chlorine demand--increase Output %, or filter run time. - Cold water (below 2400 ppm, Check Salt LED on the algae treatment. ing). - "-Pcb-" displayed and all 4 red/yellow LEDs are illuminated. A possible Printed Circuit Board...
Aqua Rite & Aqua Rite XL - Page 9

... from energizing the electrolytic cell. Indicator LED's POWER When illuminated, the Aqua Rite has input power. See description above. When illuminated steady, the salt level is advisable to operate. INSPECT CELL A flashing indicator signifies that either case, inspect cell and clean if necessary. When flashing, the pool water is on during this position there is in...
Aqua Rite & Aqua Rite XL - Page 11

... Mild Acid Washing: Use only in the pool (old pool water is necessary. To acid wash, turn the Aqua Rite on the cell indicates that you to Aqua Rite. ALWAYS ADD ACID TO WATER NEVER ADD ...off the plates) and scrape deposits off power to one gallon of plates. The Aqua Rite salt display and LED indicators operate as specified. If this self cleaning action will not remove the majority of...
Aqua Rite & Aqua Rite XL - Page 15

... Note that the colors marked on PCB 1 BLK / GND yellow 2 GRN / -DT Intellitouch black 3 YEL / +DT red 4 RED / +15 12 GRN 4 Aqua Rite YEL 3 BLK 2 RED 1 (Colors Do Not Match) green marking on the Pentair PCB do not match the Aqua Rite. GRN 4 Aqua Rite YEL BLK 3 2 RED 1 green 4 GRN Aqua Logic yellow black 3 YEL 2 BLK red 1 RED Pentair - Input power for proper wiring...
Aqua Rite & Aqua Rite XL - Page 17

...blown. Date of control and cell 2. Pool temperature (xx degrees Fahrenheit or Celsius) 2. "Power" LED not on the circuit board above the cell connector. 2. ter....of the button the display will revert back to the pool automation control display ("AL-0" which signifies "Aqua Rite") 7. Product name sent to the default salt display. "No Flow" LED illuminated The Aqua Rite has sensed a no ...
Aqua Rite & Aqua Rite XL - Page 18

... Printed Circuit Board fault has been detected. Before adding large quantities of salt, it is too high, lower salt level by draining some of the pool water out of the pool and replace with fresh water. "-Pcb-" displayed and all 4 red/yellow LEDs are illuminated. Possible causes of Nitrogen in pool water. - Aqua Rite® switch in pool/spa. "High Salt" LED illuminated Check...

Similar Questions

How Do You Change Hayward Aqua Rite Chlorinator From C To F
how do you chnage hayward aqua rite chlorinator to Ferihiet from ceseles
(Posted by mills13 1 year ago)
Aqua Rite Pro 'check System' Only Light.
I have an Aqua Rite Pro and the "Check System" LED is lit. There are no other error codes present. H...
(Posted by stlcardsfan389 2 years ago)
Aqua Rite Pro
my aqua rite pro logic is showing high temp and not generating yet the pool temp reads at 72.
(Posted by trueblueservice 10 years ago)
Goldline Aqua Rite Not Reading Salt Level Properly
I have an aqua rite salt generation system in my pool. The digital display is reading 2100 for sal...
(Posted by bpark 12 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward Aqua Rite manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.