Get support for Hayward EcoStar

Hayward EcoStar Support Question

Hayward EcoStar Support Question

Find answers below for this question about Hayward EcoStar.
Need a Hayward EcoStar manual? We have 3 online manuals for this item!
Question posted by ronaqw on April 19th, 2014

How To Reset Default Settings On Hayward Ecostar Pool Pump

The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward EcoStar Manual Pages

EcoStar Manual - Page 17

Hayward EcoStar Pump SP3400VSP Thursday 1:27p 1725rpm 380 Watts Timer 1 timer will end at 11:45p
EcoStar Manual - Page 18

to adjust, > go to enter Use + / - Configuration Menu Locked Configuration Menu press > to next item Time: Th 1:27PM + change or > skip Set Day and Time Thursday 1:27p Speed Selection rpm MAX allowed speed 3450 (600-3450rpm) MIN allowed speed 600 (600-3450rpm) Set max-speed Prime Period: Auto Sense Remote Control Mode Standalone/Hayward Set COMM Bus Address Pool Filter
Technical Guide - Page 1

Variable Speed Pump and Drive Technical Guide © 2011 Hayward Pool Products Version 2 Drive FW 1.02 Interface FW 2.55 residential Interface FW 1.00 commercial
Technical Guide - Page 4

Plumbing New Pools: When installing the EcoStar on existing pools, care should be taken to insure the maximum flow does not exceed the capacity of pipe (L) between pump suction port ... Note: length of the pipe and equipment* (fig 1). Installation - Existing Pools: When installing the EcoStar on a new pool, care should be taken to ensure proper pipe and equipment sizing to equipment ...
Technical Guide - Page 7

...size would be connected first. Bonding Lug 8 AWG (6 AWG for an EcoStar that is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the ...sub-panel and not from the filter pump relay. Installation - Voltage: 230 VAC, 60Hz, Single Phase. 2. Figure 6 Conduit Connections There are two on the pump. Electrical/High Voltage High Voltage Wiring ...
Technical Guide - Page 12

... connecting high voltage for data cable The data cable needs to point. Reinstall plugs. Wire 7 on the pump to 2 on the controller, 8 on the pump to 3 on the controller and 1 on 7 EcoStar is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the control, or in units 8 Mfg 5/19...
Technical Guide - Page 17

... included with the SVRS models. TIMERS ACTIVE LED LED will illuminate indicating the pump has stopped. The & buttons are used to edit when in the quick clean mode with pump (1 hour default timer). Page 15 Unprotected mode requires manual verification. Default settings: Speed 1 1000 RPM 29% Speed 2 1750 RPM 51% Speed 3 2500 RPM 72% Speed...
Technical Guide - Page 18

... enter the Configuration menu (fig 33). When power is supplied to the pump, the pump model will come on and run until the timer is changed or set as shown to select the Configuration menu (fig 33). 3. Programming 1. Timer 1 will have default setting of 1750 RPM (50%), 7 days a week from 12:00 am - 11:45...
Technical Guide - Page 24

.../Hayward compatible software control pressing & buttons will only recognize address 1 (Pool Filter) and address 2 (Dual Spa Filter). Set COM Bus Address Aux 1/Spa Filter Set COM Bus Address Pool Filter Set COM Bus Address Aux 2-14 Set COM Bus Address Lights button Fig 45 Page 22 Only the Menu, and Stop/Resume button is active on the EcoStar. For EcoStar interface...
Technical Guide - Page 25

...set the Drive Temp Setting (fig 48). If the Low Temp Operation is 1000 rpm (29%). Default... is Fig 48 for drive protection only Page 23 by pressing the & buttons. Fig 46 Fig 47 Note: Low Temp operation is 41º F. Press the button to protect the drive . Setting... will be asked to enable or disable the Low Temp Operation (Default is Disabled) by...
Technical Guide - Page 26

If yes, press and confirm on setting password protection. There will be asked if you would be a screen telling you have an HCP3400VSP or HCP3400VSPVR commercial EcoStar please refer to page 39 for directions on the next ...feature is being used the timer menus would like to reset to the default parameters (factory settings ) (fig 49). Programming-Configuration If you to use the timers mode to...
Technical Guide - Page 27

... 51). Timer 1 can be changed as relays on control connected pumps. Programming-Timers Stand alone/Hayward Stand alone: Both times and speeds need to be set as needed. . Press the button to run the pump if the data link fails on controller will be set to 1725 rpm (50%), 7 day operation from 12 am to...
Technical Guide - Page 32

... alternate during configuration, prior to be displayed on the display while the pump is completed and 1 or more of the timer settings matches the current time. 2. Once configuration is running. 5. If this...speed selected or timed. When the Low Temp Operation is pressed. 3. If the EcoStar you are set, the pump will begin to operate as long as one of the speed buttons or the quick...
Technical Guide - Page 33

...pump for maintenance, end a favorite speed choice or end quick clean. CHECK SYSTEM LED LED will go to the speed and duration that was set... speed for 3 seconds after adjusting speed will add the preset speed time up to the maximum set in the ...subsequent pressing of the pump to 12 hrs maximum. TIMERS ACTIVE LED LED will illuminate indicating the pump has stopped. Holding...
Technical Guide - Page 42

... Stop/Resume button after the timeout has passed, you will be reset to enter the password (fig 82). Resume configuration on page 24... If the password has been changed it may be asked to factory default by pressing and holding the speed 1 and 4 buttons at the same... to change the password you will see this screen (fig 80) to set the password and the next screen (fig 81) to the next screen....
Technical Guide - Page 45

...line voltage (page 4) and verify that the incoming line voltage has dropped below 185 VAC and pumps stops. Check fan and shroud for registry change , replace drive. If line voltage is within... be checked. Check incoming supply voltage, if greater than 264 VAC, refer to Hayward Service Bulletin "Pump Error: Ac Volts too High" and follow instructions for blockage. PFC Circuit Low ...
Technical Guide - Page 48

If the values are at "0" replace the interface. Control reads "Pool bridge comm" This indicates interference on the comm. The breaker is caused ...Tech Service for isolator. If still tripping breaker, replace drive. EcoStar is connected to a GL/Hayward control. If the values are correct, replace the drive. When it comes on, the pump will ramp up and down in speed. Install RS485 isolator,...
Technical Guide - Page 49

... to the line or load side of the filter pump relay in the control filter configuration menu and set to a dedicated 15 amp double pole breaker. Check the settings in the control (page 5). Be sure EcoStar is connected and operating via GL/Hayward control. Control reads "Pool bridge comm." Be sure they are made to not...
Technical Guide - Page 50

... automation control and is sent to come on the pump interface do not work properly. The EcoStar is connected and operating via the GL/Hayward control. Only the Stop/Resume and Menu button is inactive. wires from freezing temperatures. (page 23) My EcoStar is wired and set to the input terminals for protection of the...
Parts Diagram - Page 1

... Display Cover Motor Drive Wiring Cover Digital Control Interface Assembly Wall Mount Kit HAYWARD 28 25 24 Ctn. NOT Pressure Testable) Strainer Cover O-Ring Strainer Basket... Cover, Lock Ring, O-Ring) Strainer Cover Kit (Biguanide Sanitizer Applications Only; Pumps EcoStar™ SP3400VSP PUMP SERIES REPLACEMENT PARTS Parts for Pump Models: SP3400VSP, SP3400VSPVR 4 5 6 10 11 3 78 9 13 14...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.